Council archive · source document
002 ECM_22091773_v3_Decision Notice - Approved by Delegation of Authority MCU21 0231 · OPW22/0299
C3.4 - N1 & N2 Elevations prepared by Chris 19 August 2022
Clout Design
C3.5 - N1 & N2 Sections prepared by Chris 19 August 2022
Clout Design
Nature and Extent of Approved Use
3. The approved Multiple Dwellings is comprised of eight (8) dwellings, six (6) of which are small
dwellings, in accordance with the administrative definition under the Noosa Plan 2020.
Currency Period
4. This development approval lapses if the use has not happened by 30 August 2028, unless
an application to extend the currency period is approved by Council.
Reconfiguration of a Lot
5. The existing allotments are to be amalgamated into one allotment and a new Certificate of
Title issued to cover the newly created allotment prior to the issue of a Development Permit
for Operational Works.
Building Height
6. The maximum height of the development must not exceed 8 metres above the finished
ground level and the natural ground level except where shown on the approved plans.
7. Certification must be submitted to Council from a Licensed Surveyor which certifies that the
buildings do not exceed the maximum height requirement of this Decision Notice.
Performance Bond
8. Security in the form of a cash bond or trading bank guarantee to the sum of $25,000 must
be submitted to Council, to secure performance of all conditions of this approval, prior to the
issue of a Development Permit for Operational Works. The cash bond or trading bank
guarantee will be returned on performance of the conditions of approval less any costs
incurred by Council in respect of enforcing performance of this permit. Council reserves the
right to call upon the bond or guaranteed sum to effect compliance with conditions.
Water & Sewer Connections
9. An underground connection to reticulated water and sewerage must be provided to the
development site in accordance with the standards and requirements of Northern SEQ
Distributor–Retailer Authority (Unitywater).
10. A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority (Unitywater)
must be submitted to Council that certifies an underground connection to reticulated water
and sewerage has been provided to each the development site.
Building Appearance
11. All air conditioning units or other mechanical equipment must be located at ground level, or
otherwise fully enclosed or screened such that they are not visible from the street frontages
nor adjoining properties.
12. All deck and balcony areas above ground floor must not be fully enclosed by permanent
fixtures such as shutters, louvres, glass panelling or the like, and must remain generally open
on at least 1 side.
Fencing and Walls
13. Any street fencing must be set back an average of 1 metre from the front property boundary.
Any fencing on the front boundary must not exceed 2m in height.
14. The area of land between the fence and the front property boundary must be densely
landscaped to screen any fencing from the street.
Page 3 of 10
Document Set ID: 22091773
Version: 3, Version Date: 05/09/2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
002 ECM_22091773_v3_Decision Notice - Approved by Delegation of Authority MCU21 0231.pdfRelated documentApplication case desk ↗
About this file
- File size
- 204 KB (small file)
- File type
No other editions are linked here.