3500 3800 3300 3300 3800 3500
existing sliding door, portion of external
site boundary
site boundary
site boundary
site boundary
wall and balustrade to be removed to
facilitate proposed alterations
roof peak e-mts e-mtg e-mts e-mtg roof peak
RL31.900 existing pitch existing pitch existing pitch existing pitch RL31.900
e-lfc e-mts e-lfc e-mts
e-wdh e-wdh
e-lfc e-wdh e-lfc
existing windows and portion of
wall to be removed to facilitate
proposed alterations
e-bal e-bal
second floor second floor
RL28.500 RL28.500
e-rnd e-rnd e-wdh e-wdh
e-rnd
e-wdh
existing doors and windows
to be removed to facilitate NGL shown dashed at
proposed alterations
existing doors and windows to be building intersection
removed to facilitate proposed alterations
e-bal
first floor first floor
RL25.500 RL25.500
e-rnd
e-gar
e-gar
ground floor ground floor
RL22.700 RL22.700
1 existing eastern elevation 2 existing western elevation
- 1 : 100 - 1 : 100
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0296
AB C 20.08.21 development application issue
3 | 18 Peregian Esplanade Macushla & Robert Jackson building elevations SD 130.01 C SCALE 1 : 100
JW B 12.04.21 schematic design
JW A 26.03.21 measured drawings Peregian Beach QLD 4573 existing elevations
schematic design
1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.