Skip to the record
Accept no imitations.

Original source · versioned page text

Engineering Services Assessment - Rev 1 (1)

of 48

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Original PDF page 11, section 1. The text section number identifies this passage in the reader.

 

 

NOTES

(1) This plan was prepared for the purpose and exclusive use of

NC OLIVER GROUP of COMPANIES PTY LTD and their other
professional advisers and is not to be used for any other purpose or
by any other person or corporation.

JFP URBAN CONSULTANTS PTY LTD accepts no responsibility for
any loss or damage arising to any person or corporation who may
use or rely on this plan in contravention of these terms.

(2) The title boundaries shown on this plan were not marked at the
time of survey and have been determined from plan dimensions
only and not by field survey.

(3) Services shown hereon have been located where possible by
field survey. If not able to be so located, services have been plotted
from the records of the relevant authorities where available and
have been noted accordingly on this plan. However, the
information shown on these records pertinent to services location
is indicative only and sometimes inadequate.

AutoCAD drawing for all spot heights and codes in layers: X-RL-T,
X-CODE-T & X-NOTES-T.

(7) Tree types are estimated and tree sizes are approximate only. If
accurate identification of tree types is to be relied upon for any
purpose, then all trees shown will require on site verification by a
suitably qualified expert.

(8) These notes form an integral part of this plan. If others use this
information, they should be advised of its purpose and limitations.

(9) This plan may not be reproduced unless these notes are
included.

 

12d Project: S:\M2677\Oliver - Eumundi rd\12D\

SITE_DTM_060116.project a

Contour Interval: 0.5m °
os

PAP 0.3X2 8.0

 

/ /
/
>
(4) Prior to any demolition, excavation or construction on the site, q
the relevant authority should be contacted for possible location of
further underground services and detailed locations of all services. NV
(5) Spot heights and contours are representative of the Q
topographical terrain at time of survey, 06/01/2017.
(6) Only a small number of spot heights are shown. Refer to the

  

PROPERTY DESCRIPTION
LOT 1 on RP230931
TOTAL AREA 3740m? (Deed)
LOT 1 on RP849431

TOTAL AREA 1748m? (Deed)
LOCALITY of NOOSAVILLE
LOCAL GOVERNMENT:
NOOSA SHIRE COUNCIL

Trunk Water Main

 

BRISBANE - SUNSHINE COAST - CENTRAL QLD

PLANNERS

 

 

URBAN DESIGNERS

 

 

    
   
 
  
  
 
  
  
  

 

 

   
  
 
   
  
 
   
   
 
  
   
 
 

 

 

 

 

 

 

 

  
  
  
   
 

  

RP230931

 
  
 

ISSUES:

 

SCALE: @ A3 1:250
°

25 5 18 10 25 15 175
SCALE 1:250 at (A3) size

THIS SCALE SHOWN IS ORIGINAL DRAWING SCALE - (A3 SIZE)

DO NOT SCALE FROM THIS DRAWING - USE ONLY DIMENSIONS PROVIDED - IF IN DOUBT PLEASE ENQUIRE

SITE DETAIL

 

 

 

 

 

 

 

 

 

 

 

 

'
LEGEND
a 8 —
x © It 1} FENCE
/ £9 8, 4_
RP12Z9020 Wg LIGHT POLE, POWER POLE
. g°’——, trom records % 0 A ‘
x oe 4 >| ——a— £ ——i=}— _ UNDERGROUND ELECTRICITY, PIT, BOX
S———. 3 |
—_———s
Z aA ——=— T-6—@x— TELSTRA CABLE, PIT, BOX, POLE
S EMH ZA —_ 2
.
gs | EEE KERB AND CHANNEL, SIGN, GULLY TRAP
—N m7 1f
Retseredecevee) 18.0 wo S——— SEWER PIPE, MANHOLE
_ ae xe} SMH
o —at— D STORM WATER PIPE, FIELD INLET, MANHOLE
> SWMH
g WATER MAIN, VALVE, HYDRANT, METER
06. RETAINING WALL
Xe
TREE
“a Crovel oe TYPE GUM TREE, TRUNK DIAMETER 400mm
2% @ vel Track HEIGHT 15metres
x& » Other types: PN = Pine
& 8 PM=Palm
wv 95°43" g a eee Soret NS = Not specified
55-22)" 7 a
oO
fo
a
» |
sv
ae
9
we 4
be
“ 6/
a
x RP69404

 

NC OLIVER GROUP of COMPANIES PTY LTD

 

DETAILS:
PROJECT: PLAN: ISSUE:

M2677. 03 A

SHEET:

10F2

FILE:

      
  

 

 

: ed SURVEYED | Lem] CHECKED | mip | MORRIE anu 101-105 EUMUNDI NOOSA ROAD M2677-03A Detail.dwg
ACN 050.414 045 Al APE ARCHITECTS A ORIGINAL ISSUE 10-01-2017 __scP. DATE:
DRAWN scp | APPROVED | DNE ve MI70215_RL12.12 AHD ISSUE: DETAILS: DATE. NOOSAVILLE 10th January 2017
com 7 TNS PTD. TH wa ET HOUT TE WATTEN CONST OFT

   

 

     
Log in to download the original file

Engineering Services Assessment - Rev 1 (1).pdf · 7.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.