Original source · versioned page text
ADAMS+SPARKES Town Planning Report
Attached to the e-mail Multiple Housing Type 2 Duplex & Operational Works - IDAS Forms, Cover letter & Report - MCU17/0076 & OPW17/0224.
The original of this document is very large (13.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
NOTE:
THE ORIGINAL OF THIS DRAWING WAS PRODUCED USING
LEGEND COLOUR SEPARATION FOR GREATER CLARITY. WORKING
WITH A BLACK AND WHITE COPY MAY CAUSE ERRORS. IF
SITE BOUNDARY THIS DRAWING IS NOT IN COLOUR THEN YOU DO NOT
XX.XX EXISTING CONTOURS (AT 0.25m INTERVALS) HAVE THE CORRECT PRESENTATION AND SHOULD
CONTACT INERTIA ENGINEERING ON (07) 3857 7868.
EXISTING SEWERAGE
EXISTING WATER
EXISTING TELSTRA
EXISTING OVERHEAD ELECTRICTY
EXISTING PROPERTY BOUNDARY PP
PROPOSED BUILDING OVER LINE
PROPOSED STORMWATER
PROPOSED STORMWATER PIT
PROPOSED BUILDING BY OTHERS
5
RP81559
CONCRETE PAVEMENT EXTENT
PROPOSED CONCRETE FOOTPATH
S EX MH
EXISTING SERVICES NOTE ID 2663807 CP
EXISTING SERVICES MAY BE PLOTTED FROM SL 1.890 GTP492
DSIL -0.270
UNITYWATER RECORDS AND 'D.B.Y.D'. LOCATION OF IL -0.270
ALL EXISTING SERVICES ARE TO BE CONFIRMED ON D 2.160
SITE PRIOR TO CONSTRUCTION. CONTRACTOR TO
CONTACT 'DIAL BEFORE YOU DIG' FOR THE LOCATION
OF EXISTING PUBLIC UTILITIES PRIOR TO
EXCAVATION. ANY DAMAGE TO EXISTING SERVICES
WILL BE REPAIRED BY AUTHORITIES AT THE 1.70
CONTRACTORS EXPENSE.
1.70
0
1.7
1.00m
1.60
1.50
1.50
EDWARD STREET
EXIST. DN150 AC SEWER MAIN (SGM2531920)
1.60
0
1.6
1.8
0
1.70
CP 6
1.70
1.80
GTP 1838 RP112875
1.70
WM
1.60
1.00m
1.50
1.70
EXISTING WATER SERVICE AND
m
00
1.70
METER TO BE MAINTAINED OR
1.
UPGRADED AS REQUIRED TO SERVICE
THE PROPOSED DEVELOPMENT
USIL -0.020
EXISTING SEWER CONNECTION
TO BE MAINTAINED TO SERVICE
THE PROPOSED DEVELOPMENT
5
SP268656
FOR APPROVAL
NORTH POINT: ARCHITECT: CLIENT: SCALE BARS: PROJECT: DRAWING TITLE:
PROPOSED DEVELOPMENT CONCEPT SERVICES 7508
ICON BUILDING THE PROPERTY 0 2 4 6m 25 EDWARD STREET, LAYOUT PLAN JOB No.
DESIGN CLINIC
Unit 5B/85 Hudson Road
Albion, QLD 4010 SCALE 1:100 @ A1
NOOSAVILLE, QLD, 4566.
01 PRELIMINARY ISSUE 13.06.17 IE
ABN 82 115 498 023
E-mail: [email protected] Phone: 3857 7868
Fax: 3262 7359 DESIGNED: APPROVED: RPEQ No.
SK500 01
C COPYRIGHT of this engineering design and plan is the property of INERTIA ENGINEERING Pty Ltd DWG. No. REVISION
REV DESCRIPTION DATE DRAWN APPROVED IERNST
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.