[OCR of page images]
MULTI UNIT COMPLEX
3 UNITS
4 4
Existing <2 4
concrete
driveway 4 4
7
4
A
Existing damaged driveway
crossover to be removed and
re-instated with turf
LINDSAY CONSULTING 2%
CLI
RPEO 4928
DRIVEWAY AS PER IPWEAQ RS-049 VERSION E DATED 01/19 -
TABLE - TYPE 6 DRIVEWAY
(SPECIAL CONDITION 7m APART NOT APPLICABLE DUE TO
MULTI UNIT COMPLEX RATHER THAN DUPLEX)
be
New let
cut back
r
ut back concrete
location of proposed
rid\drakin
aoe in
xjsting
bin enclosur
Existing Kerb adaptor to be removed and is
not in use for dwelling. Dwelling stormwater
discharge is via alternative lawful point of
discharge
New concrete or permeable driv
council specifications
isting Water Meter to remain
eway to
THIS DRAWING REMAINSAHE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
ANDREW GENTNER
PROPOSED DRIVEWAY RENO
NO.31 PICTURE POINT CRES
NOOSA HEADS
DRAWING TITLE
PROPOSED WORKS
Protect your
PERSONAL
INTERESTS.
HE
EYES
EARS
BODY
HANDS
FEET
SCALES
NOT TO SCALE
SURVEY DATUM
WARNING
THE CONTRACTOR SHALL CONFIRM THE
LOCATION OF ALL EXISTING SERVICES ON
AND EXTERIOR TO THE SITE INCLUDING
WATER MAINS, SEWER MAINS, GAS MAINS,
TELECOMMUNICATIONS CABLES, ELECTRICAL
CABLES, AND STORMWATER PIPES. ANY
DAMAGE TO EXISTING SERVICES SHALL BE
REPAIRED AT THE CONTRACTORS EXPENSE.
PROPOSED WORKS
LINDSAY CONSULTING P/L WAS NOT SUPPLIED WITH A
New deck to house
rubbish bins with
timber fence screen
Existing Watering
system to remain
CURRENT CONTOUR SURVEY PLAN.
NOTE
THE ENGINEER MUST BE NOTIFIED OF
CHANGES PLANS. IF NOT, AS CONSTRUCTED)
DRAWINGS WILL NOT BE ISSUED
ASSOCIATED CONSULTANTS
It is the responsibility of the
Foreman to contact the
relevant service authorities to
ascertain the exact location of
services prior to construction.
REVISION LIST
>
ORIGINAL ISSUE 21/01/22
DIAL BEFORE
YOU DIG
{Computer File
2209170W.DWG
www.1100.com.au
S
DRAWING NUMBER SHEET] REV.
22-0917-F4 4IA