Council archive · source document
Traffic Engineering Report part 1 · MCU18/0094
Attached to the e-mail Multiple Housing Type 4 Conventional - 4 units (Covering letter, DA Form 1, Eng Plans, Eng Report, Owners Consent, Planning Report , Traffic Report) - MCU18/0094.
Traffic Engineering Report – 1723 Garnet
4 Conclusion and Recommendations
RoadPro Engineering has assessed the provisions proposed for vehicular access and parking
associated with the proposed townhouse complex located at 15 Garnett Street Cooroy.
RoadPro Engineering considers that the current layout has addressed councils points raised at the pre-
lodgement meeting. In summary,
· The fence adjacent to the visitor parking bay has been repositioned to the property boundary so
that access and egress is now possible (refer swept path diagrams) and the bay is now wide
enough to permit vehicle door opening.
· The proposed driveway provides for two-way traffic on a single lane and as such it will not be
possible for vehicles to pass whilst on the driveway, however, given the low number of trips
generated by this development a single lane access driveway is consistent with the requirements
of AS2890.1.
· It has been demonstrated (refer swept path diagrams) that the single lane access driveway with
holding bays at the front and rear of the property provides sufficient width for vehicles to enter
and leave with other vehicles in the holding bays. The provision of a convex mirror at the rear of
the property will allow drivers at the rear of the building preparing to exit the property to see other
vehicles on the driveway.
The proposed car park and property access arrangements are considered to be satisfactory.
.
www.roadpro.net.au Page 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Traffic Engineering Report part 1.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.