Council archive · source document
08/1168 - Operational Works - Landscaping, Carparking & Access, Frontage [As Published] · 142008.1168
PROVIDE SAW CUT TO SLAB
WITHIN 3 HOURS MAXIMUM
OF INITIAL CONCRETE SET, peep
Not
R= 4
CUT 100 FROM EVERY SECOND J Xu
TRANSVERSE WIRE INDUCED CRACK
CENTRALLY UNDER JOINT.
SAW JOINT (SJ)
SCALE 1:20
6mm x 110mm SQUARE HOT DIP GALVANISED
"DANLEY* DIAMOND DOWELS AT 600 CRS,
INSTALLED IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATIONS.
— an
NON COMPRESSABLE XS FORMED CONSTRUCTION JOINT
“DANLEY" DIAMOND DOWEL
SLEEVES AT 600 CRS.
CONSTRUCTION JOINT (CJ)
(DIAMOND DOWEL)
SCALE 1:20
CONTOU
Consulting Engineers 5
€2 117 061 680
50 50 -— APPROVED SEALANT.
5 APARTMENT DEVELOPMENT Ta ae a
AT 43-45 ELANDA ST, SUNSHINE BEACH
TE KOR OAK INVESTMENT HOLDINGS P/L
SL82 MESH, 50 TOP COVER. N16 TRIMMER BAR
SLAB JOINTS AS SHOWN ON PLAN. EDGE THICKENING
\ TO PERIMETER
2 ~ j RC aS
“t “e 75, 3
2 %
Test Tt |___ CBR 15 (TYPE 2.5)
COMPACTED SUBGRADE 500 __|100
min
TYICAL PAVEMENT DETAIL
SCALE 1:20
PROPOSED APPROVED v
PAVEMENT stag FLEXABLE
SEALANT OVER
\ \ |
ABUTTING PAVEMENT, INLET
PIT OR OTHER STRUCTURE
Me, FOAM BOARD
TYICAL PAVEMENT DETAIL
SCALE 1:20
4
610
BARRIER KERB
AND CHANNEL
SCALE 1:20
Rev | pate | COMMENT
ala|e
g
518) R
B | 180608 | ISSUE FOR NSC APPROVAL
A Se Reverse @ Thee plan Copyoght Other than fer fie purposes of and subsect 1 the conditions prescr Led urea he Copyrgh Act nopertoftmey Many brary
- . _ Bw meere ba mprodies stared ina robes! sysam oF Kersmited aiout Be pro: weisa pemnission of Contour Conmulirg EAgreens
(be used for constuction schout pro! amen appeal
STORMWATER DRAINS
GENERAL
General: Provide stormwater drains to connect dawnpipes, surtane drains, subso#
drains and drainage pits to the outlat point oF point of connection.
Downpipa connactions: Turn up branch pipelines with bands to meet the downpipe,
finishing 50 mm (nominal) above finished ground or pavement evel. Sed jotts
between dawnpipes and drains.
Tolerances: Comply with the Pipeline tolerances tabie, Thase tolerances are conditional
on falls to outlets being maintained and no part of a pipeline being at less than the
designated gradient.
Pipe Materials
Stormwater pipe to be F.R.C. or U.P.V.C. class SH in accordance with AS3500 3
Connection to kerb to be gaivanisad RHS in accordanoa with AS1074 with minimum
cvating mass of 500g'eq.m
Identification
Lay a detectable strip or plastic tape in the trench after pipelaying, tasting and inital
backfiling.
Pipe undertay
Genetal: Bed piping on 9 continuous underlay of bedding material, atleast 75 mm
thick after compaction. Grade the underlay evenly to tha gratient of the prpalin.
Chases: If necessary, form chases to prevent projections such as sockets and flangas
from beering on the trench bottom or undertay.
Pipa surounds
General: Place the material in the pipe surround in layers 200 mm loose thickness,
‘and compact without damaging or displacing the piping.
Anchar blocks
Itnecessary, provide anchor blocks which restrain lateral and axial movement of the
pipelines at junctions and changes of gt ade or drection.
Encasemert
Ganeral: If necessary, encase the pipeline in concrete at least 150 mm shove and
batow the pipe, and 150 mm each side or the width of the french, whichever is the
greater, Concrete; Grado N20 AS 1378.
SUBSOIL DRAINS
Genera
Provide subsoil drains to intercept groundwater seepage and provent water buk-up
behind walls and under floors and pavomants. Connect subsoil drains tb suta0e
drains of to the stormwater drainage system 2s applicable,
Pipe Size & Class
100mm minimum diamater in accordance with AS2430. 1
Pipe dopth
Provide the following minimum clear depths, measured tb the crown of the pipe,
‘where the pipe passes below the following element:
= {00 mm botow formation level of the pavement, karb or channel.
- 100 mm below the average gradient of the bottom of footings.
- 450 mm below the finished surtace of unpaved ground,
Jointing
At junctions of subsoil pipes provide toos, couplings or adaplors to AS 2438.1,
Trench width Minimum 450 mm.
Pipe undertay
General: Grade the tench floor evenly to the gradient of the pipolra. tthe tench
floor is rock, correct any kregularities: i
Chases: If nocassary, form chases to prevent projections such ms sockets and flanges
trom bearing on the trench bottom or underlay.
Pipe surrounds
Goneral: Place tha material in tha plpa steround in layers 200 mm loose thickness,
and compact without damaging or displacing tha piping
Depth of overt.
= To the underside of the bases of overlying structures such an pavements, slabs
and channals,
= To within 150 mum of the finished surface of unpaved ar landscaped areas.
Fiiter fabric
General: Provide polymeric fabric for mad from plastic yarn composed of at last 85
by waight propylene, ethylene, amide or vinyledenechloride, and containing stabilisers
oF inhibitors which provide resistance to deterioration due tb ut aviolet ight
Marking: To AS 3706.
Protection: Provide heavy duty protective covering. Store clear of the ground ard out
of direct suntight. Ouring instailation do not expose the filter fabric (0 sunlight for
more than 14 days, Fittr socks
Provide polyester permeable socks capable of retaining particles of 0.25 mm sizo.
Securely fit or Joln the sock st each joint
PITs
Finish to exposed surtaoas
Genera: Provide a smooth, samtass tinish, using stae! rowdled render or concrete
cast in staal forms,
Corners: Cove or splay internal comars.
Metal access covers and grates
Standard: To AS 3096.
Cover levels: Top of cover or grata, inchuting tame:
- In paved areas: Flush with tha pang surface.
- Inlandscaped zeas: 25 mm above finished sutace.
PUN TITLE
INTERNAL DRIVEWAY AND
STORMWATER DETAILS
panne: S083 - OPT reson 8 sheet. 7 oF @
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/1168 - Operational Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.