Original source · versioned page text
2019-03-12 Planning & Environment Committee Agenda
The original of this document is very large (10.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA 12 MARCH 2019
Page 57 of 116
Attachment 1
ABBREVIATION LEGEND
DRAWING SCHEDULE NOTES
ee eee ese uivir . GROUND LEVELS, FINISHED FLOOR LEVELS, SITE WORKS AND RETAINING ARE INDICATIVE ONLY AND ARE TO BE CONFIRMED ON
| * | TITLE REV. DATE wl AWNING TYPE? SITE PRIOR TO CONSTRUCTION. SITE PLANS ARE TO BE READ IN CONJUNCTION WITH AVAILABLE SURVEY/ENGINEERING PLANS
at eee eee oe 1 ALL DIMENSIONS ARE TO BE CHECKED WITH EXISTING AND PROPOSED SITE CONDITIONS.
[200 [PROPOSED SITE PLAN 14.01.19 ae RY Elise a - NO VARIATION MAY BE MADE TO THESE DRAWINGS WITHOUT THE PRIOR APPROVAL OF THE ARCHITECT
[202 _ [PROPOSED FLOOR PLAN PB [4019 CH CABINETRY HANDLE TYPE 1 . REFER TO ENGINEERS DESIGN, DOCUMENTATION AND CALCULATION FOR DETAILS ON SLAB, FOOTINGS, STRUCTURE, RETAINING
[202 [PROPOSED ROOF PLAN EB | 16.01.49 pee oe eR POWER OUTLET WALLS, FINISHED FLOOR LEVELS, SITEWORKS AND STORMWATER DETAILS.
500 — PROPOSED ELEVATION 5 ors eee eee ee cascia - THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS SHEETS, CONSULTANTS DRAWINGS, DOCUMENTS,
' SCHEDULES AND SPECIFICATIONS (AS APPLICABLE).
[302 _ |PROPOSED ELEVATION Er _fosazae FAL pasa TYPE 1
[nn Ne ee . THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER PIPES AND THE LIKE ARE LOCATED
fo ctasnine types AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENT GENERAL MOISTURE
[400 [SECTION + SINK DETAIL B 14.01.19 FSS FOLDING SHOWER SEAT PENETRATION, DAMPNESS, WEAKENING & UNDERMINING OF ANY BUILDING AND ITS FOOTING SYSTEM.
PO FW FLOOR WASTE
[TERRA ELEVATIONS Eons rue fore LOCATION OF ALL EXISTING ONSITE SERVICES TO BE CONFIRMED ONSITE PRIOR TO CONSTRUCTION
Mast Mee poor SHEETING TYPE - ALL TIMBER FRAMING, IN ACCORDANCE WITH AS1684 AND ENGINEERS REQUIREMENTS
eee eer ee TING TYPE? - ALL WET AREAS ARE TO BE WATERPROOF ED THROUGHOUT WITH A PROPRIETARY WATERPROOFING SYSTEM INSTALLED IN
eee ees ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. PROVIDE INSULATION IN ACCORDANCE WITH PART 3.12 OF THE BCA.
eee era - BUILDING WORKS IN ACCORDANCE WITH BCA ENVIRONMENTAL GUIDELINES.
bee OLAS eR Bonny TYE? - WETAREAS . ALL GLAZING SHALL COMPLY WITH AS1288, (DOORS AND WINDOWS SUBJECT TO HUMAN IMPACT, GLAZING TYPE AND THICKNESS
see eebek tomes wieeenser 6.38MM GRADE A LAMINATED GLASS)
Pw PARTITION WALLS
Rol aehbenty pow -TBA~ TYPE. . THE PROVISION OF ENERGY EFFICIENT LIGHTING TO COMPLY WITH EITHER THE QUEENSLAND DEVELOPMENT CODE METHODOLOGY
peat benbenen peoee wore FOR 80% ENERGY EFFICIENT LIGHTING OR THE BCA METHODOLOGY BASED ON WATTS PER SQUARE METER.
Bey nehbeaee Finis TYPE 1 - ALL WORK MUST COMPLY WITH THE BUILDING CODE OF AUSTRALIA AND AUSTRALIAN STANDARDS, AND ALL OTHER RELEVANT BY
oe envees LAWS AND AUTHORITIES. NO WORK SHALL BE UNDERTAKEN PRIOR TO APPROVAL BY A REGISTERED CERTIFIER.
See eee eal TYPE 2 - NO FOOTING, OR WALL TO ENCROACH THE TITLE BOUNDARY.
eee RAMP - _ DOWNPIPES 90MM@ ZINCALUME U.N.0, ALLOW TO CONNECT TO IN-GROUND STORM WATER DRAINS 150MMO UPVC, OR 2/90MM DIA.
Se ae ae eee 1:100 MINIMUM GRADE WITH I.0'S AT EACH CHANGE OF DIRECTION AND 6000MM CENTRES. THE PROVISION OF WATER TANKS TO
eee eee eee seein TYPE 1 COMPLY WITH QUEENSLAND DEVELOPMENT CODE.
ea aeee e oeiMELINE CHAMPER BOARD PLUMBING TO BE CARRIED OUT BY A LICENSED PLUMBER AND IN ACCORDANCE WITH THE REQUIREMENT OF LOCAL AUTHORITIES.
Wet toe Syne THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND APPROVALS. ALL HOT WATER LINES SHALL BE FULLY INSULATED.
Woo tower tye > SANITARY PLUMBING SHALL BE CONNECTED TO EXISTING SYSTEM WITH MATERIALS APPROVED BY THE LOCAL AUTHORITY.
. TERMITE PROTECTION TO BE CARRIED OUT IN ACCORDANCE WITH AS3660 AND THE REQUIREMENTS OF THE BUILDING CODE OF
AUSTRALIA PART 3.1.3.
ALL DOMESTIC HOT WATER TO BASINS, SHOWERS AND BATHS TO HAVE MAXIMUM TEMPERATURE OF 50C.
ALLOW TO SUPPLY AND INSTALL TEMPERING VALVES WHERE REQUIRED, AS NOMINATED IN THE BCA AND RELEVANT STANDARDS.
. SUPPLY AND INSTALL APPROVED SMOKE DETECTORS IN ACCORDANCE WITH ‘NCC VOLUME TWO, PART 3.7.2 - SMOKE ALARMS" AND
ALL QFES REQUIREMENTS. ALARMS TO BE INTERCONNECTED TO ACTIVATE AT THE SAME TIME, SMOKE ALARMS MUST BE
HARDWIRED TO MAINS POWER WITH A SECONDARY POWER SOURCE
. FIRE EXTINGUISHERS TO BE PLACED AS PER BCA REQUIREMENTS - CLASS 6 BUILDING
Cuan [ vssee | care | ossonencn | tana | ORANG TITLE PROUT WO
Cs Taam amt nme ae nas tna the NC OLIVER Properties NEW BUILD ———_— GENERAL NOTES & DRAWING | 16-049
~~ Seceta er 5 | pn promenecemecs SCHEDULE sue
—— nia merwraree sm, ws orammnenoenane ExetmeA
a en on —See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.