Log in to see the plans as drawnDESIGN IN ACCORDANCE WITH THE QUEENSLAND HOME
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING
PROPERTY
168.50
CODE OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
DESCRIPTION
169.00 LOT: 21 SP308933
LOCALITY : COOROY
LOCAL GOV. : NOOSA SHIRE COUNCIL
52
169.50
AREA : 38740m²/3.874ha
65
10
17
2
N
170.00
APPROXIMATE LINE OF DRIVEWAY, EXACT
LOCATION TO BE DETERMINED ON SITE WITH
0 .5 BUILDER. DRIVEWAY TO COMPLY
17 0 WITH LOCAL COUNCIL REQUIREMENTS
17 1.00
10 SITE CALCULATIONS
00
0
4
SITE AREA = 38740m²
60
10
171.5
0
GROSS FLOOR AREA = 347.85m²
PROPOSED SITE COVER = >1%
"
GARAGE
50
3'
36
°1
PAD LEVEL RL 173.01
21
39
172.5
17
0
173.0
0
173.50
00
97
6
10
26
PROPOSED
65
00
DWELLING
PAD LEVEL RL 173.90
1M HIGH RETAINING
WALLS AS REQUIRED ON NOTE:
SITE TO SPEC.
LEVELS OF PROPERTY HAD NOT BEEN UNDERTAKEN BY A
CERTIFIED SURVEYOR AT TIME OF DOCUMENTATION.
LEVELS OF DWELLING TO BE CONFIRMED ON SITE PRIOR
31 TO CONSTRUCTION.
0
°4
25 3' 55
00
06 "
0
3
10
GENERAL NOTES
1. ALL MATERIALS SHALL BE NEW. 7. PLUMBER AND DRAINER: TO LOCAL
2. FOOTING: TO ENGINEER DETAILS. AUTHORITY REGULATIONS.
FOOTINGS TO HAVE SOLID BOTTOMS 8. ELECTRICIAN: TO LOCAL AUTHORITY
AND EVEN BEARING THROUGHOUT. REGULATIONS.
3. SLAB: TO ENGINEER DETAILS 9. BRICKLAYER: GALVINISED WALL TIES
UNDERLAY WITH 200mm POLYTHENE 1 ROW AT 2 COURSES ABOVE FLASHING
WATERPROOF MEMBRANE AND ALL LINE AND 1 ROW IN THE SECOND LAST APPROXIMATE LOCATION
PROTRUSIONS. CAST ON 50mm SAND BED JOINT FROM TOP OF WALL AND @ OF WATERTANKS, EXACT
BEDDING ON APPROVED FILL. 500crs. IN BETWEEN ON EACH STUD. LOCATION TO BE
PROVIDE WEEP HOLES @ 900crs. ALONG DISCUSSED WITH BUILDER
173.50
CONCRETE STRENGTH TO BE 20MPa
AT 28 DAYS. USE TERMITE CONTROL FLASHING.
AS PER BUILDERS SPECIFICATIONS. 10. ALL WET AREA FLOOR AND SHOWER FLOORS
173.00
4. TIMBER FRAMING: ALL FIXINGS AS TO COMPLY WITH B.C.A. SECTION 3.8.1.
PER CONNECTION DETAILS AND GOOD
WORKMANSHIP. NOTE : BUILDER TO CHECK AND CONFIRM ALL
172.50
5. LININGS: AS PER BUILDERS SPECIFICATIONS. MEASUREMENTS PRIOR TO COMMENCEMENT
6. ROOFING: COLORBOND METAL SHEET OF CONSTRUCTION. DO NOT SCALE DRAWINGS,
C & H FRASER
0
ROOFING OR CONCRETE ROOF TILES WRITTEN DIMENSIONS TAKE PRECEDENCE AT
172.0
OVER AN APPROVED SARKING MATERIAL ALL TIMES. STORMWATER THROUGH P.V.C.
AND FIXED IN ACCORDANCE WITH THE PIPE TO LOCAL COUNCIL REGULATIONS.
.50
MANUFACTURERS SPECIFICATIONS.
171
BUILDER TO ENSURE ALL RELEVANT SEARCHES
HAVE BEEN CARRIED OUT REGARDING LOCATION LOT 21 NO.16 PINES ROAD
NOOSA COUNCIL
OF EASEMENTS, STORMWATER & SEWER PRIOR
TO CONSTRUCTION. COOROY QLD
APPROVED PLAN
SITE PLAN MCU22/0044 16 JUN 2022 19.11.2021
Scale: 1 : 200 Sheet: 3 of 13
as design + drafting 0410 326 991 WD104 - WORKING DRAWINGS