RFI - Appendix A- Design Plans · MCU22/0140
Plans and drawings: the text below has words only, no drawings.
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
WINDOW SCHEDU... NOTE: LEGEND - INTERNAL
DESIGN IN ACCORDANCE WITH AS 3623, DOMESTIC METAL FRAMING BC - BROOM CUPBOARD
CLASSIFICATION AND THE BUILDING CODE OF AUSTRALIA STEEL FRAME WALLS AND TRUSSES IN
NO. SIZE 16745
ACCORDANCE WITH MANUFACTURERS DESIGN
C'BD - CUPBOARD
DP - DOWNPIPE
W1 1806DH AND SPECIFICATION. DW - DISHWASHER PROV.
FW - FLOOR WASTE
W2 1806DH 2840 90 2310 90 2810 465 2810 90 2310 90 2840 DESIGN AND ENGINEERING TO BE PROVIDED TO HP - HOT PLATE
W3 2124PLD CERTIFIER PRIOR TO FRAME INSTALL. HWS - HOT WATER SYSTEM
L - LINEN
W4 2124PLD 4140 1030 2970 465 2970 1030 4140 MH - MANHOLE
W5 1806DH MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
W6 1806DH 170 3800 170 1030 70 3000 265 3000 70 1030 170 3800 170 PTY - PANTRY
R - ROBE
W7 SD2118-2 REF - REFRIDGERATOR SPACE
W8 1215SW 70 4980 90 3000 3000 90 4980 70 RH - RANGEHOOD
SH - SHELF
W9 1806DH TR - TOWEL RAIL
W10 1806DH TRH - TOILET ROLL HOLDER
3800 70 1110 1400 70 1530 1530 70 1400 1110 70 3800 UBO - UNDER-BENCH OVEN
W11 SD2118-2 WO - WALL OVEN
W12 1518SW 2900 90 1990 3000 3000 1990 90 2900 LEGEND - EXTERNAL
W13 1518SW 20 20 BV - BRICK VENEER
470 690 1820 690 470 890 80 60
UNIT 1
UNIT 2
CJ - CONTROL JOINT
W14 SD2118-2 370 2400 200 465 200 2400 370 890 470 690 1820 690 470 FC - FIBRE CEMENT SHEETING
W15 1806DH RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
W16 1806DH RB - RENDERED BRICKWORK
A
W17 1215SW RBL - RENDERED BLOCKWORK
90 x 90 LAMINATED HWD POST 5 SA - SCYON AXON
W18 SD2118-2 SL - SCYON LINEA
ON GALV. STIRRUP SM - SCYON MATRIX PANELING
90 x 90 LAMINATED HWD POST SS - SCYON STRIA CLADDING
90
300
90
ON GALV. STIRRUP WB - HARDIES NEWPORT
650 90
CJ
P'CH
640
170640
700 640
90
550
800 550
DP W1 W2 W3 DP CJ FLOOR AREAS
P'CH
640
1440
70 650
CJ CJ CJ W5 W6 DP
170
W4 Unit 2 94.02 m²
1440
170
2124PLD CJ CJ
A/C POSTION Unit 1 94.33 m²
900
METERBOX
170
2124PLD A/C POSTION
70
820 METERBOX
DP Unit 3 100.07 m²
70
820
1070
DP Unit 1 - Porch 2.12 m²
LIVING/ ENT
1070
TAP
Unit 2 - Porch 2.43 m²
ENT LIVING/ TAP
Unit 4 103.27 m²
DINING
DINING Grand total 396.24 m²
1800
W18
RA
5800
ISSUE
1800
W7
K
6240
6240
6240
G
5800
ED
# DATE DETAILS BY
L IN
6240
6240
GARAGE
CE
6400
- 23-07-21 CONCEPT ISS. DC
I
CE
GARAGE
I
L IN
345
- 06-08-21 CONCEPT ISS. A JS
ED
G
B
K
345
- 10-09-21 NHP ISSUE AN
RA
7270
A 27-09-21 WD ISSUE JB
5 M/H 555x555
7270
1500
W17
B 25-10-22 WD ISSUE DPC
820 C/S
CEILING LINE M/H 555x555
1500
W8
820 C/S
CEILING LINE
DW PROV
DW PROV
12720
CT/RH O/MW/OHC REF PROV.
11780
V/S 1.4
REF PROV. O/MW/OHC CT/RH
70
V/S 1.4
1050
DP PTY
530
70 70
1050
WM PROV. LINEN PTY
70
530
DP
720 C/S
WM PROV.
70
LINEN
70
70
TR
W16
600
720 C/S
BATH SKYLIGHT TR
1660
1660
600
W9
1500
SKYLIGHT po box 6384 p (07) 5319 1500
NICHE BATHNICHE
2230
1660
TRH
STUDY maroochydore f (07) 5450 6437
1500
1500
620 qld 4558 QBCC 1083000
2230
1000
LINEN STUDY 620 TRH
1100
1000
70
820 820 LINEN WRITTEN DIMENSIONS TO TAKE
500
1100
70 530
70 70
A/C UNIT
ROBE SH SH ROBE 820 820 PRECEDENCE OVER SCALE
500
530
70
A/C UNIT
ROBE SH SH ROBE
NICHE
M/S 2.1 M/S 1.8 UNIT 1-2
70
1000
NICHE
4515
M/S 1.8 M/S 2.1
1000
1480
4515
A/C POSTION
A/C POSTION
3500
3500
1480
BED 1 BED 2
A/C POSTION
A/C POSTION
2930
2930
2900
3500
3500
820 C/S
ENS BED 2 BED 1
2930
2930
2900
820 C/S
ENS PROJECT DESCRIPTION:
PROPOSED DEVELOPMENT
TR
TRH TR
70
TRH
300
TAP W15 W14 W13
70
DP DP
A/C UNIT HWS CLIENT:
W12 DP A/C UNIT W11 W10 DP TAP
HWS R KILDEY
780 690 405 1800 1865 1810 1845 1810 1865 1800 405 690 780 SITE ADDRESS:
LOT 616 RUBY ST
70 1000 70 1830 90 5080 265 5080 90 1830 70 1000 70 COOROY
90 90 410
1000 410 3430 70 940 70 1990 1990 70 940 70 3430 1000
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS DESIGNED BY AUSMAR
: SMOKE ALARMS TO BE HARD WIRED IN 1480 6500 6500 1480 DRAWN BY D.CHAMBERLAIN
CUSTOM
ACCORDANCE WITH B.C.A. 3.7.2. SCALE
8140 8405 JOB CODE
: REFER ELECTRICAL PLAN FOR PLACEMENT. 1 : 100
: FLOOR WASTE POSITIONS ARE INDICATIVE D-RK
ONLY. FINAL POSITIONS TO BE DETERMINED BY 16545
LOCAL AUTHORITY PLUMBING REGULATIONS. SHEET 2 OF 30
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Appendix A- Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.