ELECTRICAL QUANTITIES NBN CONNECTION LEGEND - INTERNAL
BC - BROOM CUPBOARD
DESCRIPTION No. INSTALL 1x DGPO. C'BD - CUPBOARD
DP - DOWNPIPE
FAN - CEILING FAN ONLY 12 SUPPLY & TERMINATE 1x DATA POINT CAT 6 CABLE. DW - DISHWASHER PROV.
FAN - EXHAUST 8 SUPPLY & TERMINATE 1x PHONE POINT CAT 6 CABLE. FW - FLOOR WASTE
SUPPLY & INSTALL 1x LEAD IN FROM PIT TO SIDE OF HP - HOT PLATE
LIGHT FITTING - DOUBLE SPOT LIGHT 8 HWS - HOT WATER SYSTEM
HOUSE P20 PIPE WITH DRAW WIRE. L - LINEN
LIGHT FITTING - RECESSED LED 71
SUPPLY & TERMINATE THE 2 CAT 6 POINTS IN GARAGE MH - MANHOLE
LIGHT FITTING - SINGLE 35W LED 4 TO 2-GANG SWITCH FOR INTERNAL CONNECTIONS. MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
LIGHT FITTING - WALL MOUNT UP/DOWN 8 PTY - PANTRY
POINT - DOUBLE GPO 56 R - ROBE
REF - REFRIDGERATOR SPACE
POINT - PHONE 4 RH - RANGEHOOD
POINT - SINGLE GPO 20 SH - SHELF
TR - TOWEL RAIL
POINT - TELEVISION POINT 4 TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
SMOKE ALARM 12 WO - WALL OVEN
LEGEND - EXTERNAL
BV - BRICK VENEER
CJ - CONTROL JOINT
SPOT LIGHT FC - FIBRE CEMENT SHEETING
HWS A/C UNIT RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
A/C UNIT HWS SPOT LIGHT RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
A/C POSTION SA - SCYON AXON
A/C POSTION SL - SCYON LINEA
1000
LED LED 1000 LED LED
SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
SGPO (300) DW 1000
1000
SGPO (300) DW
SGPO (1750) RH
WB - HARDIES NEWPORT
LED SGPO (1750) RH
LED
LED LED LED
2
2
LED
2 LED
LED in EAVE
2 LED 2
SGPO (1900) REF
LED in EAVE
2
SGPO (1900) REF
ELECTRICAL LEGEND LED LED
LED
LED LED ISSUE
CEILING FAN # DATE DETAILS BY
LED
- 23-07-21 CONCEPT ISS. DC
- 06-08-21 CONCEPT ISS. A JS
CEILING FAN / LIGHT COMBINATION SGPO IN CEILING FOR - 10-09-21 NHP ISSUE AN
LED LED ANTENNA BOOSTER A 27-09-21 WD ISSUE JB
2
2
SGPO IN CEILING FOR B 25-10-22 WD ISSUE DPC
LED ANTENNA BOOSTER LED
EXHAUST FAN M/H 555X555 M/H 555X555
HEAT FAN & LIGHT LED LED
WALL MOUNT
LIGHT POINT - CFL (32w / 22w) WALL MOUNT
B LIGHT POINT - BATTEN 35W LED
LED 35W LED
LIGHT POINT - LED IN CEILING IN CEILING LED po box 6384 p (07) 5319 1500
A/C POSTION
EXTERNAL FLOOD LIGHT maroochydore f (07) 5450 6437
qld 4558 QBCC 1083000
A/C UNIT
LED
A/C POSTION
WALL LIGHT
WRITTEN DIMENSIONS TO TAKE
A/C UNIT
35W LED LED PRECEDENCE OVER SCALE
LED
GPO - DOUBLE
LED
ELECTRICAL UNIT
GPO - SINGLE 1000
LED 3-4
LED
1000
GPO - DOUBLE WEATHERPROOF
SPOT LIGHT WALL MOUNT
GPO - SINGLE WEATHERPROOF
WALL MOUNT SPOT LIGHT PROJECT DESCRIPTION:
BLANK PLATE / JUNCTION BOX PROPOSED DEVELOPMENT
TELEPHONE POINT
DATA POINT
CLIENT:
TELEVISION POINT R KILDEY
HDMI POINT
SMOKE ALARM
METER BOX UNIT 3 & UNIT 4 ELECTRICAL SITE ADDRESS:
LOT 616 RUBY ST
COOROY
HWS HOT WATER SYSTEM 1 : 100
ghwu NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS
GAS HOT WATER UNIT
: SMOKE ALARMS TO BE HARD WIRED IN
WP WATER PUMP ACCORDANCE WITH B.C.A. 3.7.2. DESIGNED BY AUSMAR
: FLOOR WASTE POSITIONS ARE INDICATIVE
LIGHT SWITCH - VARIABLE POLES DRAWN BY D.CHAMBERLAIN
ONLY. FINAL POSITIONS TO BE DETERMINED BY
CUSTOM
2 D LOCAL AUTHORITY PLUMBING REGULATIONS. SCALE JOB CODE
2 - TWO WAY D - DIMMER 1 : 100
: REFER ELECTRICAL PLAN FOR PLACEMENT.
NOTE: ALL LIGHT SWITCHES LOCATED @ 1100mm ABOVE FL.
: ALL EXHAUST FANS TO WET AREAS
D-RK
UNLESS OTHERWISE NOTED,
ALL POWER OUTLETS LOCATED 300mm ABOVE FL. UNLESS TO BE DUCTED TO EAVE (AS PER N.C.C. PART 3.8)
OTHERWISE NOTED & WITH BCA REQUIREMENTS. SHEET 25 OF 30
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Appendix A- Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.