LEGEND - INTERNAL
BC - BROOM CUPBOARD
C'BD - CUPBOARD
DP - DOWNPIPE
DW - DISHWASHER PROV.
25mm RADIUS 150 90x90 LAMINATED HWD POST FW - FLOOR WASTE
HP - HOT PLATE
HWS - HOT WATER SYSTEM
450mm GAL STIRRUP L - LINEN
100 MH - MANHOLE
25mm STEP TO CONCRETE FOOTING. DOOR LINE OF FRAME
MW - MICROWAVE PROV.
VARIES
DOWN 2/M12 BOLTS TO POST FFL INTERNAL FLOOR FINISH OHC - OVERHEAD CUPBOARD
DOOR THRSHOLD PTY - PANTRY
70 MIN.
R - ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
SH - SHELF
GL TERMITE TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
PROTECTION UBO - UNDER-BENCH OVEN
WIDTH AS PER SPEC AS PER SPEC. WO - WALL OVEN
2760/4860/5260
SAND FILL LEGEND - EXTERNAL
WAFFLE-POD BV - BRICK VENEER
SLAB SYSTEM TO ENG. CJ - CONTROL JOINT
A - PANEL-LIFT DOOR REBATE OPTIONAL CONCRETE DESIGN & SPECIFICATIONS FC - FIBRE CEMENT SHEETING
PATIO SLAB RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
1 : 20 RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
CONCRETE FOOTING TO
SA - SCYON AXON
ENGINEERS DETAIL SL - SCYON LINEA
75 25 SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
G - CLADDING - DOOR SILL
SARKING TO WALLS
D - POST SECTION
AS PER FRAME 1 : 10
SPECIFICATION AS SPEC 1 : 20
TERMITE PROTECTION 265
20-25mm BATTENS SHOWER SCREEN
AS PER SPEC.
50mm ALUM. ANGLE. AS PER SPEC.
HEBEL
POWERWALL FALL TO WASTE
45
ISSUE
SYSTEM
FLOOR # DATE DETAILS BY
CONCRETER TO ENSURE 100 - 23-07-21 CONCEPT ISS. DC
WASTE
5
NEAT FINISH TO SLAB EDGE PLASTERBOARD CEILING LINING BRACKET FIXED TO HEBEL POWERPANEL - 06-08-21 CONCEPT ISS. A JS
SLAB - 10-09-21 NHP ISSUE AN
WITH 2 x No12-11x50mm HEX HEAD TYPE
A 27-09-21 WD ISSUE JB
WAFFLE-POD 17 SCREWS
25mm CAVITY B 25-10-22 WD ISSUE DPC
SLAB SYSTEM TO ENG. OR 2 x NO12-8x60mm BUTTON HEAD
DESIGN & SPECIFICATIONS SCREWS
WATERPROOF MEMBRANE TILERS BEDDING
PLASTERBOARD WALL LINING
IN ACCORDANCE WITH COMPOUND
BCA 3.8.1 REQUIREMENTS BULK INSULATION TO WALLS
AS PER BUILDING SPECIFICATION
E - SHOWER HOB - SLAB po box 6384 p (07) 5319 1500
B - HEBEL - SLAB EDGE 90mm TIMBER WALL FRAMING
maroochydore
qld 4558
f (07) 5450 6437
QBCC 1083000
1 : 10
1 : 10 WRITTEN DIMENSIONS TO TAKE
PRECEDENCE OVER SCALE
75mm HEBEL POWERPANEL
DETAILS
R1.0 SARKING TO WALLS ALUMINUM BRACKET FIXED TO FRAME CONTINUOUS HEBEL MORTAR
FRAME WITH 2 x 2.0x25mm GAL NAILS OR
WALL INSULATION AS PER AS SPEC 2 x 12-11x25mm HEX HEAD TYPE 17 SCREWS
BUILDING SPECIFICATION TO
LINE OF FRAME WALLS TO ACHIEVE R1.5 RATING TERMITE PROJECT DESCRIPTION:
OUTSIDE FACE DAMP PROOF COURSE PROPOSED DEVELOPMENT
PROTECTION
TERMITE OF HEBEL CLADDING AS PER SPECIFICATION
AS PER SPEC.
PROTECTION DOOR TRACK INSTALLED IN ACCORDANCE WITH
MANUFACTURERS SPEC.
45
AS PER SPEC TILED LEDGE CLIENT:
R KILDEY
CONCRETER TO ENSURE
20
NEAT FINISH TO SLAB EDGE
CONCRETE SLAB
SLAB AND FOOTING AS PER SITE ADDRESS:
100 WAFFLE-POD SLAB SYSTEM TO ENGINEER DESIGN LOT 616 RUBY ST
SKIM-COAT RENDER TO ENG. DESIGN & SPECIFICATIONS COOROY
SLAB EDGE FACE
DESIGNED BY AUSMAR
H - HEBEL SEPERATION WALL DRAWN BY D.CHAMBERLAIN
CUSTOM
C- HEBEL - DOOR SILL F - CLADDING - SLAB EDGE SCALE JOB CODE
1 : 10 As indicated
1:5 1 : 10 D-RK
SHEET 29 OF 30
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Appendix A- Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.