LEGEND - INTERNAL
16745 BC - BROOM CUPBOARD
C'BD - CUPBOARD
DP - DOWNPIPE
DW - DISHWASHER PROV.
100 4040 930 3070 465 2970 1030 4140 FW - FLOOR WASTE
HP - HOT PLATE
270 195 HWS - HOT WATER SYSTEM
L - LINEN
MH - MANHOLE
MW - MICROWAVE PROV.
4140 10 910 10 440 2460 805 2460 340 70 910 50 4140 OHC - OVERHEAD CUPBOARD
PTY - PANTRY
DOOR GARAGE DOOR GARAGE DOOR DOOR R - ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
SH - SHELF
TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN
PANEL-LIFT DOOR RECESS
B 75mm HEBEL / 25mm CAVITY D LEGEND - EXTERNAL
29
640 300
640 300
29 BV - BRICK VENEER
640
700 640
CJ - CONTROL JOINT
740
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
900
RBB - RENDERED BLUEBOARD
900
700
75mm HEBEL / 25mm CAVITY 75mm HEBEL / 25mm CAVITY RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
C SA - SCYON AXON
1040
CLAD WALL OVER, NO REBATE SL - SCYON LINEA
A
1040
DOOR
4797 SINK 29 DOOR
POSITION POSITION
SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
29 WB - HARDIES NEWPORT
DOOR POSITION
G
4797 SINK
DOOR POSITION
DOOR
1860
29
6470 TUB
CLAD WALL OVER, NO REBATE
DOOR
1860
6470 TUB
280 SINK
CLAD WALL OVER, NO REBATE
280
SINK
SINK
5423 TUB
5423 TUB
2505 WC
11780
2505 WC ISSUE
11780
11780
11080
# DATE DETAILS BY
10980
TUB
LOADBEARING WALL TUB LOADBEARING WALL - 23-07-21 CONCEPT ISS. DC
LOADBEARING WALL LOADBEARING WALL - 06-08-21 CONCEPT ISS. A JS
500 500
- 10-09-21 NHP ISSUE AN
500 500 A 27-09-21 WD ISSUE JB
WC H B 25-10-22 WD ISSUE DPC
1100 SHR
VB
550 550
SHR
1100 SHR
WC VB
550 550
E 29 SHR
29 SHR POSITION SHR POSITION
500 500
SHR SLAB AND FOOTINGS TO BE IN STRICT
1000
1000 SHR
500 500
ACCORDANCE WITH THE ENGINEERS SHR
3806 WC
3740 VB
SPECIFICATIONS.
3806 WC
3740 VB
SHR POSITION
3070
po box 6384 p (07) 5319 1500
3070
VB maroochydore f (07) 5450 6437
2000
2000 SHR
VB qld 4558 QBCC 1083000
1421 VB
WC
1401 VB
WRITTEN DIMENSIONS TO TAKE
PRECEDENCE OVER SCALE
WC
520
DOOR POSITION
WC
WC
520
DOOR POSITION
300
300
70 1000 SHR CLAD WALL OVER, NO REBATE
SLAB LAYOUT
740 740 F CLAD WALL OVER, NO REBATE 1000 SHR 70 UNIT 1-2
740 740
70 1480 SHR 29
1480 SHR 70 PROJECT DESCRIPTION:
1589 VB PROPOSED DEVELOPMENT
1589 VB
1845 1860 9135 1860 1845
CLIENT:
DOOR 8273 8273 DOOR R KILDEY
100 16545 100 SITE ADDRESS:
LOT 616 RUBY ST
COOROY
SLAB LAYOUT UNIT 1&2 DESIGNED BY AUSMAR
1 : 100 DRAWN BY D.CHAMBERLAIN
CUSTOM
SCALE JOB CODE
1 : 100
D-RK
SHEET 4 OF 30
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Appendix A- Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.