Reference Document - OPW23 0189
Project No. PG-10899 Page | 5 November 2023 Ref: PG-10899, 2023-10-16, ASR VER 3 DD Sunnyside CD Sunnyside Pty Ltd – Acid Sulfate Soil Investigation - Proposed Residence, 30 Mossman Court, Noosa Heads Typically the groundwater levels in the area are encountered at levels of approximately RL 0.5m to RL 1.0m. Fluctuations of +/- 0.5m are typically noted in the area. Increases in the groundwater levels often occur following significant rainfall events (floods) with the groundwater levels to as much as RL 1.5m to RL 2.0m being noted in the area. 6.0 LABORATORY TESTING Laboratory testing was undertaken in general accordance with the recommendations outlined in the QASSIT 'Acid Sulfate Soils Laboratory Methods Guidelines 2004' and was undertaken by Pacific Geotech. The results of the testing program are appended to this report. The testing program comprised of initial screening tests on recovered samples, followed by quantitative testing using the Chromium Reducible Sulfur (CRS) suite. Screening Tests Screening tests were undertaken on soil samples collected from borehole BH01. Two small sub-samples of each soil sample were prepared; one sub-sample from each sample was mixed with approximately 20mL of distilled water, and the other sub- sample mixed with approximately 20mL of hydrogen peroxide (H2O2), buffered to a pH of 5.4 with sodium hydroxide. Slurry pHs were measured with a calibrated pH meter. The pH of the distilled water/soil slurry (pHF) was measured approximately one hour after mixing, whilst the pH of the hydrogen peroxide/soil slurry (pHFOX) was measured approximately one to two hours after mixing. The pH screening tests can be used for the preliminary identification of a potential or actual ASS using a combination of three trigger factors as follows: a) The strength of the reaction with peroxide is a useful indicator but cannot be used alone. Organic matter and other soil constituents such as manganese oxides can also cause a reaction. b) A pHFOX value at least one unit below pHF may indicate a potential ASS. The great the difference between the two measurements, the more indicative the value is of a potential ASS. The lower the final pHFOX value the better the indication of a positive result. c) If the pHFOX is less than 3, and the other two conditions apply, then it strongly indicates a potential ASS. The more the pHFOX drops below 3, the more positive the presence of sulfides. In broad summary, several of the ‘natural’ soil samples tested did show a strong indication of ASS presence at depths greater than 3m below ground level. The results
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.