geotech report · MCU15/0087
Slope Stability and Geotechnical Assessment 1 Natasha Avenue, Noosa Heads Table 1: Retaining Wall Design Parameters Friction Effective Unit Active Passive Angle, *At Rest Cohesion Weight Pressure Pressure Description (’ 3 Ko (c’, kPa) ( kN/m ) Ka Kp degrees) Controlled Sand Fill 0 33 19 0.3 0.5 3.3 Alluvium Sand - Loose 0 28 18 0.36 0.5 2.8 Alluvium Sand – Medium 0 33 19 0.3 0.5 3.3 Dense Alluvium Sand – Dense to 0 35 20 0.27 0.5 3.7 Very Dense * These are modified rather than in-situ Ko values, assuming that at least a small amount of wall movement (say about 0.1 to 0.3% of the wall height) could occur. 6.8. Piled Footings Should piled footings be adopted, it is recommended that all piles be designed in accordance with the requirements of AS2159 – 2009. Using methods described in Woodward and Boitono (1961) and Zhang and Einstein (1998), the geotechnical parameters recommended for the pile design are shown in Table 2. It is likely that bored piles (non-displacement type) will be adopted on the site. The parameters assume that the pile base is clear of debris. If seepage occurs in the pile base, dewatering should be conducted prior to pouring concrete. Vibrations associated with driven piles could cause instability in the dune escarpment. They should only be adopted in consideration of all risks. Coffey should be consulted for advice on the use of driven piles if this option is to be considered. Screw piers may also be suitable providing they are able to meet the load requirements, that they have the structural capacity and that they can met the design life requirements. It should be noted that unit stress design values will vary for different pile diameters and founding depths, and different values may be applied depending on the type of pile adopted, founding depth, installation method, level of supervision, static load and pull-out testing (depending on the design philosophy i.e. pile spacing and whether uplift is the critical load). Pile design should be checked for serviceability, and for lateral loading that may potentially occur. Coffey GEOTKPAR02068AA/A 4 12 August 2015
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
geotech report.pdfRelated documentApplication case desk ↗
geotech report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.