Vehicle loading / unloading and waste storage and collection areas The service areas are visible from Parkridge and the existing resort
do not significantly impact on the visual or acoustic amenity of facilities. They are of large scale and the impacts are only
open space. superficially acknowledged.
The site and floor plans do not indicate the location of the
Parkridge development. Many of these properties will have a
direct view of the hotel service courtyard.
Criteria For Assessment – Acceptable Outcomes Not – all numeric controls have been evaluated based on the site
area zoned open space/recreation and on the portion of the
proposed building situated on that zoning. No comment is made on
the portion of the site zoned for accommodation purposes.
AO8.1
Food or drink outlets are ancillary to a recreation or community The proposed food and drink outlets are not ancillary to any
activity on the same site. community activity.
AO8.4
Food and drink outlets within a sporting club or community use, The food and beverage areas have a floor area of app. 900 m.sq.
including indoor and outdoor dining space, does not exceed a (inclusive of service areas) This vastly exceeds the numeric
gross floor area of 150m2. control
AO9
Function facilities do not exceed 300m2 of gross floor area If utilised for function purposes, the ground floor area available for
excluding where located on the portion of Lot 3 SP246584 to the functions is app. 490 m.sq. It is noted that there is included a
north of Walter Hay Drive. Function Cold Room in the back of house areas. Therefore the
intent of the ground floor public space seems to be multi-
functional. Indeed, the scope of back of house services indicates
use as commercial restaurant, bar and function area.
AO15.1
Buildings and structures are no more than: The South West Elevation presents a height of 21.550 m to the
(a) 4 meters in building height (for buildings) and height (for existing resort entry. This is derived from the drawing 2/DA2.01
structures) measured from the ground level if within the area of a incorrectly labeled as North Elevation. Further, the entire West
commercial jetty lease; or Elevation has a visual height of 14.8 meters. This is further
(b) otherwise 8 meters in building height (for buildings) and height exacerbated by an embankment at the lower level, which will add
(for structures) measured from the ground level. another 4 to 5 meters in elevation.
AO15.2
Where excavation is required, the maximum portion of the
exposed external façade of the building cannot exceed the
respective building heights in AO15.1
AO16.1
Site cover does not exceed: The portion of the site zoned open space is app. 17,900 m.sq.
(a) 45% for the portion of Lot 3 SP 246584 north of Walter Hay The building footprint on the open space zoning is 2,400m.s.q
Drive, Noosaville; or Site Coverage of 10% is therefore exceeded by 610m.sq.
(b) otherwise 10%.
AO17.1
Buildings or roofed structures do not generally exceed a gross The gross floor area located within the open space zoning is
floor area of: L0-1160m.sq. L1-700m.sq. L2 – 1850 m.sq. and L3 1190 m.sq.
(a) 1000m2 for the portion of Lot 3 SP246584 to the north of Giving as total of 4900 m.sq.
Walter Hay Drive, Noosaville; or This vastly exceeds the control.
(b) otherwise 100m2 excluding major sporting clubs, clubhouse
facilities which do not exceed 800m2.
AO17.2
The maximum length of wall in one plane is typically not more The wall planes of the proposed buildings are typically 25 – 33 m
than 15 meters or for a building containing an indoor sports court, in length. This exceeds the control
30 meters.
AO18.1
Buildings and roofed structures are set back at least: (a) 20 meters The minimum setback from a street frontage is app. 12 meters.
from street frontages; This does not comply with the control.
(b) 4.5 meters from internal roads;
(c) 3 meters from another building on the same site;
(d) 10 meters from the boundary of land in a residential zone or
the Rural residential zone, except for a Major Sport, recreation and
entertainment facility where there is a 50 meter setback;
(e) 4.5 meters from property boundaries not otherwise specified
Yours sincerely,
John Cochrane Architect NSW Rn 4759