Original source · versioned page text
EngSWMP
Attached to the e-mail Response to Information Request MCU16/0079 (email 2 of 3).
Plate 11 Insert hook near edge of Plate 12 Position each lifter either side
grate of the grate
Plate 13 Lift grate and move grate to Plate 14 Lift grate above the support
one side frame
Plate 15 Reinstated non hinged grate
To reinstate a non-hinged pit grate
1. Place lifting hooks though the grate. Note do not place hooks at the very edge of
the grate, as this will make it difficult to place grate on the support.
2. Lift the grate into position and lower onto the supporting frame (Plate 14), ensuring
that the grate sits level with the finished surface. If the grate does not sit securely
remove the pit cover and check for debris in the pit cover frame, then try to lower
grate again.
3. Check final position of the cover, ensuring that the cover sits flush with the surface
and does not create a trip or traffic hazard. (Plate 15)
Note all grates should be reinstated to the original condition.