FILE

 

 

GENERAL:

+ THESE ORAWINGS SHALL BE READ COMRINCTION WITH ALL
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND
SPECHICATIONS AND WITH SUCH OTHER WRITTEN BSTRUCTIONS
AS MAY BE ISSUED OURING THE COURSE OF THE CONTRACT.
ALL OISCREPANCIES SHALL BE REFERRED TO THE ARCHITECT
FOR DECISION BEFORE PROCEEDING WITH THE WORK.

+ ALL DIMENSIONS RELEVANT To SETTING OUT AND OFF-SITE
WORK SHALL BE VERIFED BY THE CONTRACTOR BEFORE
CONSTRUCTION AND FABRICATION IS COMMENCED, THE
ENGINEER'S ORAWINGS SHALL NOT BE SCALED.

= DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE
FOR MAINTAINING THE STRUCTURE IN A STABLE CONDITION AND
ENSURE WO PART [S OVER-STRESSED,

+ WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT To
EXISTING FOOTINGS, THE EXACT LEVEL OF THE UNDERSIDE OF
THE FOOTINGS SHALL BE OBTANED AY TEST PITS PRIOR TO
EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE
SHALL GE CARRIED OUT AS DETALED ANO THE EXISTING
STRUCTURE SHALL BE MAINTAINED DY A STABLE AND UNDAMAGED
CONDITION.

+ WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH
THE RELEVAHT CURRENT S.A.A, CODES UNCLUDING ALL
AMUNOMENTS? AND THE STATUTORY AUTHORITIES"
REQUIREMENTS, EXCEPT WHERE VARIED BY THE CONTRACT
DOCUMENTS.

+ ALL DIMENSIONS ARE IY MILLIMETRES UMLESS STATED
OTHERWISE. ALL LEVELS ARE EXPRESSED IN METRES.

= CONSTRUCTION OF ANY MASONRY WALLS OR OTHER PERMANENT
LOADING HUST NOT BE BURT ON CONCRETE SLABS OR BEAMS
UNTIL FORMWORK SUPPORTING SAME HAS BEEW REMOVED.
HOWEVER PROPS AND FORMWORK SHALL NOT BE REMOVED BEFORE
THE MINIMUM TIME SPECIFIED. DISTRIBUTE MASONRY ON SLAB
ADJACENT TO ITS FINAL POSITION PRIOR TO CONSTRUCTING
WALLS.

ALL NOM LOADBEARING WALLS SHALL BE KEPT CLEAR OF THE
UNDERSIDE OF SLABS AND BEAMS BY 76mm UNLESS OTHERWISE
SHOWN.

+ THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS GEEH
OFSIGHEO FOR THE FOLLOWING LIVE LOADS UNLESS NOTED
OTHERWISE.

AREA LUVE LOAD &Pal
GENERAL us
BALCONES 20
GARAGES: 25

- WIND LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH
AS 1170 PART 2 BASED OW THE FOLLOWING :

REGION 28
TERRA CATEGORY 12
SHEELOWG FRA TIPLIER pie
TOPOGRAPHIC MULTIPLIER id
ULTOHATE LIMIT STATE SITE WIND SPEED V,., In/s) : S45
WTERNAL PRESSURE COEFFICIENT 103, 0.3

> AM ALLOWABLE BEARBIG PRESSURE IN NATURAL GROUND OF
400 kPa AT S00Gme INTO EXISTING HATURAL GROUND
HAS BEEN ASSUMED TO PROVIDE A PLE LAYOUT
REFER MORRISON GEOTECHNICAL REPORT No 1WO68/SW

+ ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE
MATERIAL AND WATER,

= SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN
EXCAVATED FACE IS WOT STABLE,

= ALL WALLS AND COLUPINS SHALL BE CONCENTRIC WITH
SUPPORTING FOOTINGS UNLESS OTHERWISE NOTED ON THE
DRAWINGS.

= ALL CONCRETE WALLS SHOWN ON PLAN WITHOUT CONTINUOUS
FOOTOIGS SHALL FOUND ON 300 x 200 GUN) HASS CONCRETE
STRIP FOOTINGS. LARGER FOOTINGS & REDE, SHALL BE USED
WF REQUIRED BY GULOER OUE TO HETHOD OF CONSTRUCTION
ADOPTED FOR WALLS.

= UNLESS APPROVED BY THE STRUCTURAL ENGINEER, EXCAVATIONS
SHALL NOT EXTEND BELOW A LIKE DIPPING AT &S DEGREES AND
AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS.

= WHERE FOUNDATION MATERIAL DIFFERS FROM THAT DESCR@ED WY
THE SITE INVESTIGATION REPORT GR LOCALISED SOFT SPOTS ARE
FOUND, THE ENGINEER SHALL GE NOTIFIED AND IF NECESSARY THE
MATERIAL SHALL BE EXCAVATED ANO BACKFILLED WITH WEAK Mix
CONCRETE,

= THE SITE 55 TO GE STRIPPED L ALL VEGETATION REMOVED FROM
ThE BULODK AREA. GRUB MOLES TO BE BACKFALED It LAYERS
AS WWOECATED OW NOTE BELOW.

~ FLED BULOOG PLATFORMS SHALL GE BURT UP BILAYERS &
UNFORMLT CONPACTED TO A POMNUM OF 95% OF THE STANDARD
MAXIM ORY DENSITY AS RECOMMENDED IN AS. 3798 5.1.
TESTING SHALL BE TO A.S. 1789 EL1 2 EL? WITH THE FLL MOCSTURE
CONTENT WITHIN THE RANGE OF -4.0% TO 0.5% OF THE STANDARD
‘OPTHSUM HOISTURE CONTENT.

CONCRETE:

- ALL WORKMANSHIP AND MATERIALS SHALL BE WV ACCORDANCE
WITH AS. 3600.

= CONERETE STRENGTH GRADE £ COVER FOR PARTICULAR ELEMENTS
SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:

ELEBENT Coven CONCRETE STRENGTH GRADE
FOOTINGS 50 B
SLABS ON GROUND 30 2
SUSPENDED FLOOR SLABS 30 se
BALCONY SLABS 0 ao
COLUBNS. 0 a0

~ HAX. AGGREGATE SIZE + 20me
SLUMP » Soma +/- Bem IAT POINT OF DISCHARGED

~ THE CONTRACTOR IS TO NOTHY THE STRUCTURAL ENGINEER
WRITING OF ANY ADMIXTURES TO BE USEO IN THE CONCRETE
MIX, MO ADHIXTURES SHALL BE USED WITHOUT WRITTEW
APPROVAL BY THE STRUCTURAL ENGINEER. CALCIUM CHLORIDE
WKL NOT GE PERMITTED AND SHALL WOT BE USED UNDER ANY
GRCUMSTANEES.

= CONCRETE TESTING - PROACT ASSESSMENT IS REQURED AS
PER AS TE

= ALL FORMWORK SHALL CONFORM TO A.S. 3610, RESHORMG NOT
PERMITTED.

~ REINFORCEMENT SYMAOLS:-

R - PLAIN ROUND BAR GRADE R2SON TO A.S.4671
NW - DEFORMED BAR GRADE OS00N TO A.5.4571
RF + DEFORMED FABRIC MESH GRADE DSGL TO A.5.4671

‘ThE NUMBER FOLLOWING THE BAR SYHBOL IS THE NOMINAL BAR
DIAMETER #1 PELLIMETRES.

~ SIZES OF CONCRETE ELEMENTS DO MOT INCLUDE THICKNESS OF
APPLIED FORSHES.

~ BEAM SIZES ARE SHOWN DEPTH FIRST AND OXCLUDE SLAB
THICKNESS.

= UNLESS NOTED OTHERWISE ALL FORMED EDGES AND CORMERS OF
CONCRETE MEMBERS SHALL HAVE 20mm CHAHFERS.

= EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE
QATAINED FROM WORKSHOP ORAWANGS PRIOR TO SCHEDULING OF
REINFORCEMENT, ANO ARE NOT TO EXCEEO DIMENSIONS WHERE -
SHOWN ON STRUCTURAL DRAWINGS.

- NO CHASES, HOLES GREATER THAN 1S0mm DIAMETER, OR
EMBEOMENT OF PIPES GREATER THAN 40mm DIAMETER OTHER

. THAN THOSE SHOWN ON THE STRUCTURAL ORAWINGS SHALL BE
MADE Of THE CONCRETE SLASS. FOR ALL OTHER CONCRETE
YEMBERS NO PENETRATION, CHASES OR EMBEDHENTS SHALL BE
BADE WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER.

+ CONDUITS CAST PTO CONCRETE MEMBERS SHALL BE SPACED AT
HAXBQMH DISTANCE POSSIBLE AND UNDER NO UIRCUMSTANCES
CLOSER THAN A CLEAR SPACING OF TWICE THE LARGER CONDUIT
GIAMETER FROM PARALLEL REINFORCEMENT OR ANY OTHER
CONDUIT.

= REQSFORCEMENT 1S SHOWN DIAGRAMMATICALLY AND NOT
NECESSARAY WW TRUE PROJECTION.

= 00 NOT CUT REINFORCEMENT ON SITE TO CLEAR PENETRATIONS.
DISPLACE REWFORCEMENT SLIGHTLY AS WECESSARY TO CLEAR
BLOCKOUTS.

+ SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE
POSITIONS SHOWN, UNLESS APPROVED BY THE STRUCTURAL
ENGINEER.

= WELDING OF REINFORCEMENT 1S NOT PERMITTED.

= REINFORCEMENT SHALL BE BENT COLD & ACCORDANCE WITH
AS. 3600 EXCEPT WHERE APPROVED BY THE STRUCTURAL
ENGINEER, NO REBEMOING SHALL BE PERMITTED UNLESS
APPROVED BY THE STRUCTURAL ENGINEER.

ALL REINFORCEMENT SHALL BE SECURELY SUPPORTEO IN ITS
CORRECT POSITION DURING CONCRETING BY APPROVED PLASTIC
BAR CHAIRS, SPACERS OR SUPPORT BARS. MAXIMUM
CENTRES OF SUPPORTING CHARS SHALL BE f0¢am FOR FABRIC,
600mm FOR BARS UP TO Tne DIAMETER, 900mm FOR BARS tan
AND GREATER.

- WHERE WO STEEL IS SHOWN ON THE DRAWING AT RIGHT ANGLES
TO MAD! REINFORCEMENT PLACE Y12-300 ON THE SIDE OF THE
HUAN REINFORCEMENT REKOTE FROM THE OUTSIDE OF THE
CONCRETE. ALL OPENBIGS AND RE-ENTRANT ANGLES ® THE
CONCRETE SHALL HAVE 2/WIZ TOP AND BOTTOM ALONG THE
ENCLOSING EDGE AND PROFCTING 35 PAST CORNERS.

= CONSTRUCTION BREAK LOCATIONS AND DETARS SHALL BE
APPROVED BY THE STRUCTURAL ENGINEER PRIOR TC
CONSTRUCTION.

+ THE FACE OF ALL CONCRETE AGAINST WHICK NEW COMCRETE IS
TO GE CAST 15 TO BE THOROUGHLY HECKAMCALLY SCABBLED,
FULLY EXPOSDIG THE AGGREGATE MATRIX.

~ ALL CONCRETE SURFACES ARE TO BE CURED FOR SEVEN DAYS
AFTER CASTING USING A METHOD APPROVED BY THE
STRUCTURAL ENGINEER.

= ALL UNREPORCED MASONRY WALLS ARE TO BE SEPARATED FROM
ABUTTING CONCRETE WITH TWO LAYERS OF SUPER ALCOR.

= MASONRY WALLS WOT COINCIDING WITH LOAD BEARING WALLS
UNDER HUST NOT BE BULT GN CONCRETE SLABS OR BEAMS
UNTEL FORMWORK SUPPORTING SANE HAS GEEM REMOVED.
GRSTRIBUTE MASONRY OM SLAB PRIOR TO CONSTRUCTING
WALLS.

= FIRST SLAB BAR IS TO BE POSITIONED MAX 00am FROM
FACE OF BEAMS, 2. WALLS AND SLAB THIKENGNGS
PARALLEL 10 BAR. FRST BEAM TE TO BE PLACED MUCKUM
‘Soue FROM FACE OF COLUMM OR SUPPORTING WALL UNDER.

RETAINING WALLS:
~ RETADING WALLS SHALL BE BACKFRLED AS FOLLOWS:

COR 1S MAX PL > 1. FRL SHALL BE PLACED IN 200mm MAX
(LOOSE! LAYERS AND COMPACTED 10 96% MODIFED Bi
ACCORDANCE WITH AS 1289, TEST E21.

RETAINING WALLS WITH THEIR UPPER EDGE RESTRAINED BY
FLOOR SLABS SHOWN ON THESE STRUCTURAL DRAWINGS SHALL BE
BACKFILLED AS FOLLOWS:

CBR 1S MAX PLL ef2. FILL SHALL BE PLACED WW 200ee HAX
(LOOSE! LAYERS ANO COMPACTED TO 95%. MODIFIED
ACCORDANCE WITH AS 1289, TEST £2.1.

TESTING OF BACKFILL: ORE FLO DENSITY TEST PER (40H?
fOR PART THEREOF) EVERY FOURTH LAYER TO AS 1289. TEST
2.4 BY A WAT.A. REGISTERED LABORATORY,

RETAINKG WALLS SHALL WOT BE BACKFALED UNTE A
HINDSUM 3% DAYS AFTER CASTING.

= PROVIDE 100me OtA AGRICULTURAL DRAINS BEHIND ALL
RETARING WALLS AND AS INDICATED ON GETALS WITH
ADEQUATE FALL TO OUTLET. ORAS SHALL GE BEDDED
Oma GRAVEL, MINIMUM 150 COVER.

= PROVIDE Soma OlA WEEPHOLES AT 1090 MM MAXIMUM CENTRES
WN LOCATIONS AS INDICATED OM RETAINING WALL DETABS.

BLOCKWORK:

= BLOCKWORK SHALL HOT BE CONSTRUCTED TO A HEIGHT GREATER
THAN 2400 ae PRIOR TO GROUTDAG CLEAN-OUT BLOCKS SHALL
BE PROVIDED IN ALL CORES AT BOTTOM COURSE OF EACH
FILLED LET.

= HO CHASES OR HOLES SHALL BE MADE WITHOUT WRITTEN
APPROVAL BY THE STRUCTURAL ENGINEER.

ALL BLOCKWORK AND MATERIALS AND WORKMANSHIP SHALL
COMPLY WITH AS 3700. BLOCKS SHALL BE “AS” SERIES WITH
‘A CHARACTERISTIC UNCONFINED COMPRESSIVE STRENGTH OF 15
Pa.

ALL 140 BLOCKWORK & 190 SIGLE SKIN EXTERNAL BLOCKWORK
SHALL BE "HT BLOCKS AT REMFORCED £ FRLED CORES UNO.

MORTAR SHALL BE MADE BY HECHANICAL MIXERS DX ACCORDANCE
WITH AS A123 1 THE FOLLOWING PROPORTIONS BY VOLUME OF
TYPE A PORTLAND CEMENT : HYDRATED UME : PIT SAKD.

+ BELOW AND ABOVE DAMP PROOF COURSE - E176:3 IMAI

HOLLOW BLOCKS SHALL HAVE A FULL FACE-SHELL BED OF
MORTAR. SOLIO BLOCKS SHALL BE FULLY BEDUED IN MORTAR.
BED JONTS AND PERPENDS SHALL NOT BE RAKED.

FOR UNREWFORCED BLOCKWORK, BUILD IN HORIZONTAL JOINT
REINFORCEMENT EVERY COURSE LAPPED 499 mm AROUND
CORNERS. CONTINUE THROUGH FILLED CORES.

ALL NON-LOAD BEARING WALLS SHALL BE BURT TO WITHON 70
sum OF SLAB SOFFITS AND HAVE THE YOU, SO FORMED, FALED
WITH & SUITABLE COMPRESSIBLE FRLER.

ALL WALLS SHALL BE Bonf=0 OR TED AT THER BTER-
SECTIONS, UNLESS DETARED OTHERWISE.

GROUT FOR FILLED MASONRY SHALL HAVE Fc « 70 MPa,
MAXIMUM AGGREGATE SIZE + éma

MOEMUM CEMENT CONTENT OF 300 kg/cubic metre.
SLUMP = 230 +/- 30mm

= GROUT FALLING SHALL BE THOROUGHLY RODOEO USING A PLA
ROUND BAR.

= CONTROL JOINTS TO BE LOCATED AT MAXIMUM 6.0 @ CENTRES
URLESS NOTED OTHERWISE,

= AUL WALL TES To BE STADLESS STEEL
IW ACCORDANCE WITH AS 2699.

LOADBEARING BRICKWORK

= ALL BRICKWORK SHALL BE CONSTRUCTED IN ACCOROANCE WITH
THE AUSTRALIAN STANDARD CODE AS 3760,

= ALL BRICKWORK SHALL COMPLY WITH THE SPECFICATION AND
CURRENT CODES OF PRACTICE

SAA AS 3700 - SAA MASONRY

SAA AS 1275 - BURNT CLAY AND SHALE BULDNNG BRKKS

SAA AS 1226 - METHOOS OF TESTING OF BURNT CLAY AND
SHALE BUILDING BRICKS

SAA AS 269% - METAL WALL TEES FOR MASONRY CONSTRUCTION

BRIEKS

1. ALL TESTING OF BRICKWORK SHALL GE CARRED OUT“B:
ACCORDANCE WITH AS 3760

2. THE CHARACTERISTIC COMPRESSIVE STRENGTH OF CLAY BRICKWORK
(FRB) SHALL BE 6.3 MPa WITH MORTAR EEG.3. (MA)

3, CLAY RICKS SHALL HAVE A CHARACTERISTIC UNCOKPINED
COMPRESSIVE STRENGTH OF 20 He.

= MORTAR SHALL BE MADE BY MECHANICAL MIXERS Of ACCORDANCE WITH
AS A123 i THE FOLLOWBG PROPORTIONS BY VOLUME OF TYPE A
PORTLAND CEMENT : HYDRATED LIME : PIT SAND. '
~- BELOW AND ABOVE DAMP PROOF COURSE - E/6.3 D4)

= BED XONTS AND PERPEHDS SHALL NOT BE RAKED. ‘

WHERE GROUT FILLBGG TO BRICKWORK IS SHOWN USE GROUT
SPECFIED BN BLOCKWORK. |

- WORKMANSHIP

1 ALL WORK SHALL BE CARRIED OUT BY ACCORDANCE WITH AS
3760. a

2. BRICKS SHALL BE PLACED WITH THER FROGS UPPER-MDST
By THER FINAL POSITION WITH A MENDQUH OF MOVEMERT
AND TAPPDNG. ANY BRKKS WIECH ARE HOVED AFTER THE
MORTAR HAS LOST ITS PLASTAUTY SHALL BE REMOVED
READ. {

STEELWORK:

+ ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDAACE
WITH AS 6100.

= ALL WELDS 6 CFW ALL ROUND, UNLESS WOTEO OTHERWISE.

= F.S.8.W. NOKATES COMPLETE PENETRATION FALL STRENGTH
6UTT WELD.

= SP ISTRUCTURAL PURPOSE! CATEGORY WELOS SHALL BE USED FOR
WELDING OF ALL STRUCTURAL STEELWORK.

 

= WELDNG SHALL BE PERFORMED BY A QUALIFED WELOER IN
ACCORDANCE WITH AS 1554 PART 1

= ALL BOLTS TO BE M26 UNLESS KOFED OTHERWISE.
= AUL BOLTS TO BE GRADE 8.8/5 UNLESS NOTED OTHERWISE.

= BOLT TYPES IAKD DESIGNATIONS. WHERE USEO) SHALL BE AS
FOLLOWS:

«4.6/5 - COMMERCIAL BOLTS TO AS tlt AND AS 1112 SNUG
TIGHTENED.

- 8.8/S = HIGH STRENGTH STRUCTURAL BOLTS, MUTS AND
HARDENED WASHERS TO AS 1252. SHUG TIGHTENED ONLY.

. GLE/TF = HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE,
FULLY TENSIONED TO AS 1511 IN FRICTION TYPE JOINT
AND UMLESS NOTED OTHERWISE, WITH CONTACT SURFACES
LEFT UNCOATED.

« $.9/T8 - HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE,
FULLY TENSIONED BY A BEARING TYPE JOKT.

= ALL BOLTS, WUTS AND WASHERS DICLUDING HD. BATS/REO
ARE TO BE HOT DI GALVANISED. ALL CAST ® FERRULES AND
HASONRY ANCHORS TO BE PASSIVATED ZC COATED. ALL
GALVANISED COMPONENTS TD BE CAST DxTO CONCRETE MUST BE
PASSWVATED.

= THE FOLLOWING STEELWORK SHALL BE HOT DIP GALVANISED:
= ALL COLD FORM SECTIONS
+ PLATEZANCHOR ROD ASSEMBLIES CAST INTO CONCRETE.
» TUBULAR BRACES, ROOS OR COLUMNS BUILT INTO BRICK OR
BLOCKWORK.
+ ALU EXTERNAL STEELWORK,

= PROVIDE YOmm THXK PLS. PLATES THROUGHOUT, UNLESS WOTED
OTHERWISE.

= ALL STRUCTURAL STEEL FOUNG DETARS ARE TO BE BASED OW
ALS.C. STANDARDISED STRUCTURAL CONNECTIONS, UNLESS
WOTED OTHERWISE. ALL BOLT HOLES 2mm OVERSIZE UNO.
HOLES FOR HD. BOLTS ma OVERSIZE UNO. BOLT HOLES IN
STEELWORK CONNECTING TIMBER SHALL PROVIDE A SHUG FIT
LE. HOT GREATER THAN SMO LARGER THAN BOLT DIAMETER.

= STIFFENER PLATES WHERE DETALED ARE TO BE PLACED OW
BOTH SIDES OF WEB TO U.B.'S AND U.C'S.

- THE ENDS OF ALL TUBULAR MEMBERS ARE TO BE SEALED WITH
3mm THK PLATES AND CONTINUQUS SEAL WELDS, UNLESS:
DETARED OTHERWISE.

= ALL MOLES & PLATES AND STEEL MEMBERS SHALL GE DRLLED,
EXCEPT FOR PURLIN AND GIRT HOLES WHECH HAY BE PUNCHED.

~ WHERE DETAILS PREVENT THE WORMAL INSTALLATION OF CFW'S.
GRIND THE EDGE OF THE HEMBER TO FACWITATE THE
INSTALLATION.

= CAMBER TO SE AS NOTED ON THE DRAWINGS.

= FOR CLEANING AND PAINTING OF STRUCTURAL STEELWORK,
REFER SPECICATION.

~ UNLESS SPECIFIED OTHERWISE
CLEANING AND PAINTING OF STRUCTURAL STEELWORK:
« ABRASIVE BLAST CLEAM TO CLASS 2 /2
| ONE COAT TAUHANS DURAZOR NO. ? - KNIMUM DRY
FAM THCKAESS OF 0.07Sam

ALL STRUCTURAL STEELWORK BELOW GROUND TO BE ENCASED BY
WZS CONCRETE 75mm ALL ROUND, UNLESS NOTED OTHERWISE.

~ CONCRETE ERCASEO STEELWORK SHALL BE WRAPPED WITH FGW41
FABRIC, UNLESS OTHERWISE SHOWN

= FOR CONCRETE ENCASED STEELWORK, PADITING SHALL EXTEND
Wome INTO THE CONCRETE. THE REMAINDER OF THE ENCASEO
STEELWORK SHALL BE UNPAPTED AND FREE OF LOOSE RUST.
LOOSE MILLSCALE, DIRT, O AND GREASE.

~ BEFORE FABRICATION IS COMMENCED THE CONTRACTOR SHALL
SUBMIT 3 COPIES OF THE WORKSHOP DRAWINGS TO THE
EWGHEER FOR REVIEW.

= THE CONTRACTOR SHALL PROVIDE AND LEAVE OI PLACE UNTE
PERMANENT BRACIKG ELEMENTS ARE CONSTRUCTED. [SUCH
TEMPORARY BRACING AS IS NECESSARY TO STABAL
STRUCTURE DURDIG ERECTION.

~ THE MUMBER OF PURLINS SHOWN IS INDXATIVE ONLY. iT 5S
‘THE BULDER'S RESPONSIBLITY TO EWSURE THE CORREC
DUMBER OF PURLINS ARE USED TO SATISFY SFACI
REQUIREMENTS.

FORMED ANGLE PURLINS TO SUPPORT DIAGONAL CU’

bevelopment Permit Operational! viorks No:

TIMBER GENERAL:

= ALL TIMBER WORK TO BE By ACCORDAKCE WITH:
~ AS 1720.1 - 17 TOBER STRUCTURES CODE.
TAS Wek - 199 TOBER FRAMING CODE:
+ BUILDING CODE OF AUSTRALIA AND AUSTRALIAN DOMESTIC
CONSTRUCTION MANUAL.

= ALU TIMBER MEMBERS SHALL CARRY AW INDUSTRY STANDARD
LABEL IDENTIFYING ‘THE STRESS GRADE, SEASONING CONDITION
AMO TIMBER SPECHS WHERE APPLIKABLEL

 

= CAMBERS AND BOWS TO LINTELS TO BE UP.

= BOLTING SCHEOULE:
= EDGE DISTANCES = SPACING
M10 - Stam
M12 - Stam
H16 - 80am
M20 -10oa8,

 

ALL BOLTS TO TRBERWORK TO BE GRADE 6.6/1 ULH.O.
(HOT APPLICABLE TO MASONRY ANCHORS & CAST-M BOLTS)

BOLTS, NUTS & WASHERS TO BE HOT OP GALVANISED.

BOLT HOLES WN STEEL PLATES SHALL PROVIDE A SHUG FIT

NOT GREATER THAN @.See LARGER THAN BOLT DIAMETER.

WASHERS TO TIMBER:

#12 BOLTS......505qlx 3 THICK

416 BOLT: sq x 5 THICK

26 BOLTS.....153q x 5 THICK

H26 BOLTS...852q x 6 THICK (REFER TO DETAR ORAWINGS!

AT THE END OF THE DEFECTS LIABILITY PERIOD, ALL BOLTED CONNECTIONS
THROUGHOUT ENTIRE PROACT MUST BE RETGHTENED,

  

™™ Sunshine Coast Regional Council

= AT DIAGONAL RIDGES AND VALLEYS, FIX ea Site COMMENDED FO!: APPROVAL

ROOF SHEETING, UNLESS DETARED OTHERWISE.

+ ROOF AND/OR WALL SHEETING SHALL BE FEED TO oR
GRTS IK ACCORDANCE WITH MANUFACTURER'S
RECOMMENDA THOS.

~ SLOTTED HOLES:
WHERE ©.A/TF BOLTS ARE USED IN SLOTTED HOLESIA
SPECIAL WASHER OR COVER PLATE, WOT LESS THAM Gmm

from wathin the watien

   

eee ccomearumeasian ™ TBLANS APPROVED

Date: ...
Name:

Signature: ....

desenerecneeeeenee 23.6.2 OOF...

    

 

Delegated Authorising Officer

 

any fore witha
Gonauf ting Eagoveers conailtates an infringement f copyright.
DSCLANER

(Biskeney funn Cora tig Engineers accepts #0 Cesperbiity far
the accuracy ér far any consequence resulting from the use
or aiteration af this drawing in elects

Oravings i electronic farm shoud be checked for accuracy against
the equivalent revision hard copy iasued by Blakeney Huns
Coraudting Engineers.

  
  

,
‘obtained from the Archites

 

 

GWE BKM BKM

DRAWN DEB IGNEO CHECKED

 

 

 

ne OR by<- APR o9

 

 

 

B.K MUNNS-RPEG No. 4469
Sey was
Geen S465.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A __{OP WORKS APPROVAL 75.05.09] GWE
P2_ | PRELDUNARY ISSUE 30.96.09] GWE
P1_ [PRELIMINARY ISSUE 2r96.09| GE
REV. | AMENDMENT bate | patuats|

 

PROPOSED RESIDENCE
LOT 10 PARK ROAD
NOOSA HEADS

QLD 4567

PROKCT

THE PENINISULA AVIATION
TRUST

CUENT

CECILIA BROWN DESIGN

 

 

ARCHITECT

GENERAL NOTES

 

 

 

ORAWING TITLE

BMCE

   

BLAKENEY MUNNS
CONSULTING ENGINEERS

ACN 1120613 448
BRISBANE OFFICE:

PH O41 S15 480
FAX 07 S479 2678
EMAIL = [email protected]
PO Box 1803

TOOWONG QLD 4066

OFFICES:
BRISBANE AND SUNSHINE GOAST

 

 

 

 

09007 + S0.01 A

PROECT No. OWG No, REY.

 

 

{

 

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_0578 - Approved Plans [As Published].pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.