DANYA COOK TOWN PLANNING Appendix A Amended Engineering Plan Prepared by RECOR Pty Ltd
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 sections
Section 2
dWM
LEGEND - EXISTING
dTU
dTU
dTU
PROPERTY BOUNDARY
dWM
//// //// //// //// ////
EDGE OF PAVEMENT
dTU
dTU
25.0 MAJOR CONTOURS (1m INTERVAL)
dTU
MINOR CONTOURS (0.25m INTERVAL)
dWM
dTU
dTU
/ / / / / / / / FENCE
dTU
D D STORMWATER DRAINAGE
EXISTING STREET
dWM
E E E ELECTRICITY - ABOVEGROUND
dTU
dTU
TREE TO BE REMOVED
WATER (BYDA)
dTU
dWM dWM
3 4
1 SP254372 SP254372
dE dE ELECTRICITY - UNDERGROUND (BYDA) TRANSITION NEW KERB AND SP254372
dWM
dTU
dTU
dTU dTU TELSTRA (BYDA) CHANNEL NEATLY TO EXISTING
dTU
S S S SEWER (BYDA) JOIN NEATLY TO EXISTING FOOTPATH
NOMINAL LOCATION OF EMT A EMT F EMT J
SP254372 SP254372 SP254372
DRIVEWAY TO BE CONSTRUCTED
dTU
dTU
dWM
LEGEND - PROPOSED IN ACCORDANCE WITH NOOSA
MH S S S S S S S S S S S S S S
dTU
/ / / / / / / / / / / / / / / / / / / / /
PROPERTY BOUNDARY SHIRE COUNCIL STANDARD
PROPOSED 3m WIDE EASEMENT
////
DRAWING RS-049 AND RS-050 EXISTING TREE TO BE
/ / / / / / /
/
AS PER UNITYWATER
E
dTU
dTU
/
EASEMENT REMOVED IF REQUIRED
dWM
/
(S)
NOMINAL LOCATION OF NOOSA SHIRE COUNCIL
/
R E Q U I R E M E N T S
////
/
dTU
/
KERB AND CHANNEL STANDARD PROPERTY STORMWATER KERB ADAPTER
/
E
/ / / / / / / / / / / / / / / / / /
/
/
////
OUTLET. BUILDER TO ENSURE MAX. CAPACITY IS NOT
/ / / / / / / / / / / / / / / / / / / / / / / /
/ / /
/ / / / / / / / / / / / / / / / / / / / / / / /
/
/ / / / / / / / / / / / / / / / /
BUILDING PAD
/
/
/
dTU
/
EXCEED IN ACCORDANCE WITH NSC CODE.
dTU
/
/
/
dWM
/ /
////
/ / / / / / /
/
E
NEW SEWER CONNECTION TO
/
/
/
ASPHALT PAVEMENT (D) (D) (D)
/
dTU
/
(S)
/
/
NEW TYPE B1 KERB IN ACCORDANCE WITH IPWEAQ STD BE PROVIDED
/
/
/
/
////
/ / /
CONCRETE DRIVEWAY / FOOTPATHS
/
/ /
/
DWG RS-080. EXISTING SWALE TO BE FILLED IN AND
E
dTU
dTU
STORMWATER DRAINAGE VERGE GRADED TO MATCH INTO EXISTING FOOTPATH
////
(D) (D) (D)
dWM
dTU
E
(S) SEWER MAINTAIN EXISTING NOMINAL LOCATION OF FUTURE
////
(S)
CONCRETE FOOTPATH BUILDING PAD . FINAL
(W) WATER 25
BUTLER STREET
LOCATION AS PER REQUIRED
dTU
dTU
E
////
M37808
dWM
SETBACKS. ANY EARTHWORK
dTU
////
REQUIRED TO BE <100m3.
E
1
/ / / / / / / / /RP127953
(S)
/ / / / / / / /
////
dTU
dTU
E
dWM
NEW WATER SERVICE AS PER
dTU
////
2
UNITYWATER REQUIREMENTS 10 RP127953
JOIN NEATLY TO EXISTING FOOTPATH
E
////
dTU
(W) (W) (W) (W)
dTU
10
dWM
dTU
ANNEX STRUCTURE TO
//
E
//
NEATLY SAWCUT EXISTING PAVEMENT AND / / / / / / / / / / / / / BE DEMOLISHED.
/
MATCH TO EXISTING PAVEMENTS LEVELS
/
dTU
dTU
E
/
/
/
/
dWM
dTU
//
/
/
//
NOMINAL LOCATION OF
E
/
/
DRIVEWAY TO BE CONSTRUCTED
////
/
/
(D) (D) (D)
dTU
dTU
/
/
IN ACCORDANCE WITH NOOSA EXISTING DWELLING
/
E
/
/
////
dTU
dWM
SHIRE COUNCIL STANDARD
/
TO BE RETAINED.
/
/
DRAWING RS-049 AND RS-050
/
////
/
/
/
E
/
dTU
dTU
E
/
/
dE
////
/
/
dTU dE
dWM
/
/
E
E
dTU dE NOMINAL LOCATION OF NOOSA SHIRE COUNCIL dT
/
/
/ / / / / / / / /
U
///
dE
dWM dTU STANDARD PROPERTY STORMWATER KERB ADAPTER
/
E
dE
dTU
dWM OUTLET. BUILDER TO
dEENSURE MAX. CAPACITY IS NOT
E
dTU
EXCEED IN ACCORDANCE WITH
dE NSC CODE.
dTU
dTU
E
dTU dWM
dWM
dWM
dTU
dE 6m TRUNCATION FROM
E
dTU
E
dTU dWM
dE EXISTING PROPERTY
GRUB AND BACKFILLdTEXISTING SWALE DRAIN. AREA
dTU
U dE
dTU d dE BOUNDARY.
dE
TO GRADEdSMOOTHLY
dWM FROM EXISTINGTU FOOTPATH
E
dTU
dE
dT
TU dWM
TO NEW BACK OF KERB. REINSTATE WITH dWM TURF.
U
dTU dE
dTU Section 3
MH
dE
E
dTU dWM dTU dE
dTU
dT MH
dE
dWM
dTU U
dTU dE dWMdE dE dE dE dE dE dE
dTU
dE
dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM dWM
E
dTU dWM
dWM
dTU dTU d dTU dTU
WM dTU dTU dTU dTU dTU dTU dTU dTU dTU dTU dTU dTU
dTU dTU dTU dTU dTU
dTU
dE
dTU
E
U
dT
dT
dTU dTU U
E
dE
dTU dTU dTU
dT
NOTES
U
EXISTING KERB AND CHANNEL E
1. SURVEY UNDERTAKEN BY BENNETT AND BENNETT DATED
dT
E
U
5/4/24
E
dT
dTU dTU dTU dTU dTU
U
dTU dTU dTU dTU
dE CULLINANE STREET
E
dE
dE
dE
E
dE
dE
E
FOR APPROVAL ONLY
North Point Approved Project Address Title
40 CULLINANE STREET, TEWANTIN LAYOUT PLAN
N
For and on behalf of RECOR Pty Ltd.
Scale ENGINEERING & PROJECT SERVICES Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE
B 04.07.24 RFI AMENDMENTS JB MP 1:200 0 2 4 6 8m www.recor.au | ABN 89 647 469 707 WALT CONSTRUCTION 40 CULLINANE STREET, TEWANTIN A1
A 08.05.24 ISSUE FOR APPROVAL AB MP COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's Project Number Drawing Number Revision
20240072 C020 B
client. This drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK 'Issued For Construction' in the revision description.