Appendix E - Existing Dwelling House Plans (For Information Purposes Only)
Plans and drawings: the text below has words only, no drawings.
Original PDF page 8, section 1. The text section number identifies this passage in the reader.
ELECTRICAL LEGEND TO SCALE ON A2
ELECTRICAL NOTE:
OR S LED LIGHT/ LED ON SENSOR - ENSURE ALL ELECTRICAL WORK IS INSTALLED AS PER THE RELEVANT
LED LED
AUSTRALIAN STANDARDS.
FLUORESCENT LIGHT - EXACT LOCATION OF ELECTRICAL POINTS MAY VARY ON SITE DUE TO
CONSTRUCTION REQUIREMENTS
WALL MOUNTED LIGHT LOCATED 2.1m FROM F.F.L
WL
GENERAL NOTES:
SPOTLIGHT LOCATED ON SOFFIT
-GPO HEIGHTS TO BE 300mm AFL UNLESS ABOVE A BENCH
(AB) WHERE THEY SHALL BE @1050mm AFL U.N.O.
DOUBLE GPO -ALL LIGHT SWITCHES (WALL PLATES) TO BE @1000-1200mm U.N.O.
-ALLOW FOR RANGEHOOD INSTALLATION OVER STOVE
SINGLE GPO /COOKTOPS
-ALL A/C UNITS TO BE PROVIDED WITH POWER AS APPLICABLE
MW DW MICROWAVE / DISHWASHER SINGLE GPO UNDER HEIGHT, W.P. SPP AND ISOLATION SWITCH TO EXTERIOR.
BENCH -DIRECT WIRING TO ELECTRICAL OVENS,UP RIGHT
COOKERS, & HWS UNITS.
HARDWIRED ISOLATOR [email protected] FROM F.F.L -WHERE APPLICABLE, WIRING TO BE PROVIDED IN SLAB
TO KITCHEN ISLAND BENCH.
-ENERGY EFFICIENT LIGHTING FOR A MINIMUM OF 80%
DBL WEATHERPROOF [email protected] FROM F.F.L OF TOTAL FIXED INTERNAL LIGHTING AS PER SUSTAINABLE
HOUSING REQUIREMENTS
GPO SGL/DBL WITH RELATIVE NOTES -STANDARD TV ANTENNA MOUNTED ON ROOF AS TYPICAL.
3000x2000x1000 AC MOTOR UNIT IN SOLAR PV PANELS ON ROOF
ROOF CAVITY - ENSURE APPROPRIATE OVER - NUMBER & LOCATION KITCHEN POWER OUTLETS:
LIGHT SWITCH
CLEARANCES ARE MAINTAINED (61KG) TBC BY INSTALLER
GAS -ALL SINGLE & DOUBLE POWER POINTS FOR ISLAND
LED
TV POINT DUCTED EHWS BENCH @ 750mm (IF REQUIRED)
DP DP A/C DP DP MB DP
-RANGEHOOD POWER POINT @1800 OR AS PER APPLIANCE SPEC.
-REFRIGERATOR POWER POINT @1900
DRY 1.8
WM UB
DRY &
LED
WM
SD
HARD WIRED INTERCONNECTED SMOKE DETECTOR WL -PROVISION FOR SEPARATE POWER POINTS FOR WALL
LED
LED OVEN TOWERS, MICROWAVES, & DISHWASHERS IF APPLICABLE AS
MECHANICAL VENTILLATION FAN LED LED REQUIRED
DATA LED LED
NATIONAL BROADBAND NETWORK OUTLET 1.1 AFL
LED LED
LAUNDRY POWER OUTLETS:
AB 0.95
NBN DATA LED LED
(GARAGE) DATA/PHONE 0.3 AFL IN HOUSE
AB 0.95
LED
LED LED AC AC AC -(NO BENCH OVER) WASHING MACHINE DBL POWERPOINT @ 1050mm
AB
LED
SD SD SD
GHWS LED
EHWS OR ELECTRIC / GAS HOT WATER SERVICE -(BENCH OVER) 1x WASHING MACHINE POWERPOINTS@ 700mm & 1x
DRYER POINT OVER @ 1800mm
AC
MH
2-WAY 2-WAY RETURN SD 2-WAY
LED
A/C AIR CONDITIONING EXTERNAL UNIT LED
SD LED
SD LED LED
AB UBO RH AB F AB
A/C AIR CONDITIONING UNIT INTERNAL SPLIT SYSTEM A/C
A/C
DP DP ACCP
USB ON 2-WAY
METER BOX -LOCATION T.B.C. ON SITE GPO LED LED 2-WAY
LED
LED LED
MW DW
CEILING FAN LED LED LED
AY
3-W
A/C
LED LED LED
LED
CEILING FAN - WITH LIGHT
AIR CONDITIONING VENT LOCATED IN MH
A/C A/C
CEILING/BULKHEAD
ACCP AIR CONDITIONING CONTROL PANEL LOCATED DATA
LED
1.3m FROM F.F.L LED LED
AC GPO ON
LED
CEILING
RETURN RETURN AIR VENT
C
AIR CONDITIONING DISCLAIMER NOTE:
A/C VENTS & OTHER RELATED ITEMS TO BE POSITIONED AS REQUIRED
BY SPECIALIST AND MAY VARY FROM POSITIONS SHOWN ON PLAN DUE DP DP DP DP
TO EFFICIENCY & WARRANTY REQUIREMENTS.
WL
GPO ON
CEILING
Electrical Plan
C
Scale 1:100
NBN
C:\Olivet Design\1. HOMES IN DESIGN\STROUD HOMES\PROJECTS\2022\LOT 11 #12 ROBIN PLACE, LAKE MACDONALD - 11ROB\CADS\LOT 11 #12 ROBIN PLACE.pln
DP DP
APPROVED
This plan is certified for compliance with the requirements
of the BUILDING ACT 1975, the BUILDING
REGULATION 2006, and attached approval conditions.
2022-4454
REFER DECISION NOTICE
Project BA
Copyright Notice: All house plans produced by the builder/designer Notes: Madden Developments Pty Ltd
Client Drawing name:
N REVISION R2 Wind class: Flood level: Scale:
and the information contained within these documents are the exclusive
property of the builder/designer. These house plans cannot be copied
UPGRADE ITEMS SHOWN IN RED ABN: 52 169 872 486
QBSA Lic No: 1284666
Kellie Wilks Electrical Plan CONSTRUCTION PLAN SET 14/10/22
R1 MARK UPS 02/11/22
N3 TBC 1:100 @A3
@A2
Dimensions shall not be obtained by scaling. All Project Project status: Soil class: BAL:
or reproduced, in part or in whole in any form or by any method without R2 MARK UPS 09/11/22
the express written consent of the builder/designer. The house plans dimensions are in millimeters unless noted otherwise. LOT 11 #12 ROBIN PLACE, LAKE CONSTRUCTION TBC 12.5
Setout dimensions shall be verified on site prior to any
provided by the builder/designer are provided to the customer with a work
107 Sugar Road Maroochydore QLD 4558,
Phone: 07 5444 2521 MACDONALD, QLD 4563 Plot date: A0.8
limited license to construct one home only.
being carried out. Any problems shall be directed Email: [email protected] Design: MOD WILDFLOWER 300 Proj. No. 11ROB
to the builder for clarification & correction 9/11/2022
GSPublisherVersion 0.73.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.