Appendix E - Existing Dwelling House Plans (For Information Purposes Only)

of 16

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn

Original PDF page 14, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                                                                                                                                                             TO SCALE ON A2




     REFERENCE CODES                                                              BRANDING OF STRUCTURAL PLYWOOD
       ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE                              EACH SHEET OF STRUCTURAL GRADE PLYWOOD SHALL
       BUILDING ACT 1975 - 1991 AND ALL CODES REFERRED                            HAVE THE FOLLOWING INFORMATION LEGIBLY AFFIXED
       THEREIN.                                                                   THERON BY THE MANUFACTURER AT THE POINT OF
                                                                                  MANUFACTURE AT LEAST ONCE:
                                                                                  (A) THE MANUFACTURERS NAME OR REGISTERED
       PRELIMINARIES                                                              MARK.
       ALL CONSTRUCTION METHODS, MATERIALS &                                      (B) THE WORD 'STRUCTURAL' OR PRODUCT
       WORKMANSHIP MUST COMPLY WITH THE BUILDING ACT                              DESCRIPTION.
       & SUBSEQUENT AMENDMENTS AND ALL AUST. STD's                                (C) REFERENCE TO THE STANDARD, ie., AS/NZ 2269.
       REFERRED THEREIN.                                                          (D) THE GRADE OF OUTER PLIES (FACE FIRST, BACK
       IT IS THE BUILDERS RESPONSIBILITY TO VERIFY THE                            LAST), eg., CC, CD OR DD. WHERE NON-STANDARD
       CONTENTS OF THIS DOCUMENT BEFORE                                           VENEER GRADES ARE USED AS PERMITTED IN CLAUSE
       CONSTRUCTION IS COMMENCED.                                                 3.4.1(c), BRANDING SHALL INCLUDE A DESCRIPTOR THAT
       WRITTEN MEASUREMENTS ARE TO THE FACE OF                                    NON-STANDARD VENEER QUALITY HAS BEEN USED IN
       TIMBER FRAMING OR THE BRICKWORK & ARE TO TAKE                              THE PLYWOOD ASSEMBLY.
       PRECEDENCE OVER SCALED MEASUREMENTS.                                       THIS REQUIREMENT MAY BE MET BY REFERENCE TO A
       ALL LEVELS ARE TO BE VERIFIED ON SITE.                                     PRODUCT NAME OR DESCRIPTION THAT REFERENCES
                                                                                  THE NON-STANDARD VENEER QUALITY IN THAT
       CONCRETOR                                                                  PRODUCTS SPECIFIC MANUFACTURING SPECIFICATION.
       ALL CONCRETE SHALL COMPLY WITH AS:3600.                                    (E) THE BOND TYPE OF THE GLUE LINE, i.e., A BOND
       FOOTINGS AND SLABS SHALL COMPLY WITH AS:2870 -                             (F) AN INDICATION OF THE STRESS GRADE OF THE
       1986.                                                                      SHEET, e.g., F7
       WHERE LOCAL AUTHORITIES REQUIRE SOIL TESTS &                               (G) THE PANEL CONSTRUCTION CODE e.g., 17-24-7
       ENGINEERED FOOTING AND SLAB DETAILS, THE                                   (H) IF IMMUNIZED OR PRESERVATIVE-TREATED,
       ENGINEERS DETAILS TAKE PREFERENCE OVER DRAWN                               BRANDING IN ACCORDANCE WITH AS/NZ 1604.3.
       DETAILS WITHIN THIS DOCUMENT.
                                                                                  GIRDER TRUSS NOTE
       CARPENTER                                          ALL GIRDER TRUSSES TO BE SUPPORTED BY 3xMGP10
       ALL TIMBER SIZES ARE THE MINIMUM REQUIRED UNDER    OR 2xMGP12 STUDS OF A SIZE COMMON TO THE WALL
       THE CODES, WALLS ARE 2400mm UNLESS OTHERWISE       OR 2xMGP10 OF A SIZE COMMON TO THE WALL AT EACH
       NOTED.                                             SIDE OF AN OPENING IN ADDITION TO THE JAMB STUDS
       WC DOORS ARE TO BE SWUNG TO OPEN OUT OR BE         WHEN THE GIRDER TRUSS IS LOCATED OVER AN
       FITTED WITH LIFT OF HINGES IF LESS THAN 1200M      OPENING WHICH DOES NOT EXCEED 2460mm IN WIDTH
       FROM PAN TO WALL.                                  UNLESS NOTED OTHERWISE ON THESE PLANS.
       TIMBER SIZES TO BE AS PER THE TIMBER SIZES TABLE   IF IN THE EVENT THAT THE GIRDER TRUSS LOCATIONS
       OF THE BRACING PLAN & THE TIE DOWN DETAILS         ARE ALTERED, THE BUILDER & OR THE TRUSS
       DETAILS TO BE AS PER THE TABLE ON THE BRACING      MANUFACTURER ARE TO INFORM THIS OFFICE SO THAT
       PLAN. ROOF TRUSSES TO BE AS PER ENGINEERED         AMENDED DRAWINGS CAN BE ISSUED.
       DESIGN BY AUTHORIZED MANUFACTURERS AND SHALL
       BE FIXED IN ACCORDANCE WITH THEIR DETAILS.
       TRUSSES TO BE BRACED STRICTLY IN ACCORDANCE                                NOTES
       WITH THE MANUFACTURERS RECOMMENDATIONS.          - ALL TIMBER FRAMED WALLS TO WET AREA'S TO BE
                                                        LINED WITH F.C SHEET OR WR BOARD.
                                                        - ALL HANDRAILS TO BE 1000mm MIN. ABOVE FINISHED
       OTHER TRADES                                     FLOOR (CARPET / TILES ETC.) AND WITH 125mm MAX.
       UNLESS OTHERWISE SPECIFIED:                      SPACING BETWEEN BALUSTRADING.
       THE WALLS SHALL BE SHEETED WITH 10mm GYPROCK     - DOORS TO W.C's TO HAVE LIFT OF HINGES FITTED IF
       AND 6mm VILLA BOARD TO THE WET AREA'S.           LESS THAN 1200mm CLEAR WIDTH FROM PAN TO WALL.
       CEILINGS TO BE SHEETED AS REQUIRED BY THE        - FIRST FLOOR TIMBER FLOORS TO HAVE AN APPROVED
       MANUFACTURER & THE ROOF TRUSS CENTRES SEE        "WET AREA" FLOORING FIXED IN ACCORDANCE WITH THE
       THE MANUFACTURERS DETAILS.                       MANUFACTURERS SPECIFICATIONS.
       CEILING GYPROCK TO BE FIXED DIRECTLY TO THE      - ALL LAMINATED BEAMS TO HAVE FULL WIDTH BEARING
       UNDERSIDE OF THE ROOF TRUSS BOTTOM CORD AS       AT EACH END.
       REQUIRED BY THE MANUFACTURER.




                                                                                                                                                                                                                                                                                                                                                               C:\Olivet Design\1. HOMES IN DESIGN\STROUD HOMES\PROJECTS\2022\LOT 11 #12 ROBIN PLACE, LAKE MACDONALD - 11ROB\CADS\LOT 11 #12 ROBIN PLACE.pln
                                                        - MASONARY CONSTRUCTION TO AS:3700.
       ROOF SHEETING TO BE FIXED AS REQUIRED BY THE     - TERMITE PROTECTION TO BE IN ACCORDANCE WITH
       MANUFACTURER TO METAL BATTENS.                   AS:3660 & SHALL BE AN APPROVED PROPRIETARY
       ROOF TILES TO BE FIXED AS REQUIRED BY THE        SYSTEM.
       MANUFACTURERS IN RELATION TO THE SPECIFIED       - ALUMINIUM SLIDING WINDOWS TO BE INSTALLED IN
       WIND RATING.                                     ACCORDANCE WITH AS:1288
       BRICKWORK SHALL BE STRAIGHT, PLUMB & LEVEL       - INSULATION TO THE EXTERNAL WALLS AND CEILINGS
       (WITHIN THE CODE FOR BRICKWORK) & HAVE VENEER    TO BE AS NOTED ON THESE PLANS
       TIES AT MAX. 600mm CENTRES BOTH HORIZONTALLY     - WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER
       AND VERTICALLY.                                  SCALED DIMENSIONS

     ROOFWATER / DRAINAGE NOTES
     - RAINFALL INTENSITY OF 250mm / hr WITH ARI OF 20                            SITE NOTES
     YEARS (BRISBANE)                                                             - PLATFORM IMMEDIATELY SURROUNDING THE
       AS PER PART 3.5.2 OF THE N.C.C., THE ROOF AREA PER                         DWELLING TO FALL AWAY FROM THE DWELLING AT A
       DOWNPIPE IS CALCULATED USING THE STRAMIT QLD.                              SLOPE OF 1 IN 20 MINIMUM OVER 1M TO A EARTH DRAIN
       QUAD EAVES GUTTER WITH AN EFFECTIVE CROSS-                                 AS INDICATED ON THE SITE PLAN.
       SECTIONAL AREA OF 8100sq.mm. ACHIEVING A MAX.                              - THE SURFACE DRAIN TO DISCHARGE EVENLY WITHIN
       ACTUAL ROOF AREA PER DOWNPIPE OF 40m².                                     THE SITE AND WITHOUT NUISANCE TO ADJOINING
       WHICH GIVES A MAX. PLAN AREA OF 49.8m² @ 5°, [email protected]°, 48.3m² @ 15°, 47.0m² @ 20°, 45.3m² @ 25° & USING                      - MAX. 1000mm HIGH TIMBER RETAINING WALL WITH 65Ø-
       100 X 75mm DOWNPIPES.                                                      AG PIPE (TO DISCHARGE TO STORMWATER LINE) &
     - AS PER PART 3.1.2 OF THE N.C.C. IN ACCORDANCE WITH
       AS / NZ 3500.3.2, UPVC STORMWATER PIPELINES
                                                                                  GRANULAR BACKFILL BEHIND & TO BE WHOLLY
                                                                                  CONTAINED WITHIN THE SITE, ONLY IF INDICATED ON                                                                                                                                               GENERAL NOTES:
       WITH AThis
               FALL
                  plan isOF
                                  APPROVED
       HAVING A SMOOTH (NON-PROFILED) INTERNAL BORE
                               1:100
                          certified       MIN. &with
                                    for compliance  A NOMINAL       DIAMETER OF
                                                      the requirements
                                                                                  THE SITE PLAN.                                                                                                                                                                                   1. ALL BUILDING WORKS TO BE IN COMPLIANCE WITH THE N.C.C. 2016.
                                                                                  - HEIGHT OF FENCE INCLUDING THE HEIGHT OF THE
       100mm ACHIEVES of the BUILDING ACT 1975, the BUILDING
                                   A HYDRAULIC CAPACITY OF 8L/s,
                REGULATION 2006, and attached approval conditions.                RETAINING WALLS ARE NOT TO EXCEED 2000mm ABOVE                                                                                                                                                   2. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH
       GIVING A MAX. ACTUAL ROOF AREA OF 114.7m² OR A                             NATURAL GROUND LEVEL, ONLY IF INDICATED ON THE                                                                                                                                                      STRUCTURAL AND CIVIL ENGINEERING, DRAWING AND TRUSS LAYOUTS.
       MAX. PLAN AREA OF                110.2m² @ 5°, 105.2m² @ 10°, 101.0m²
                                  2022-4454                                       SITE PLAN.
       @ 15°, 97.2m² @ 20°, 93.2m² @ 25° PER STORMWATER                           - DRIVEWAY SLOPE NOT TO EXCEED 1:4 OR AS PER                                                                                                                                                     3. THESE PLANS HAVE BEEN PREPARED FOR THE EXCLUSIVE USE OF
                          REFER      DECISION      NOTICE
       PIPE.
                                    Project BA
                                                                                  LOCAL COUNCIL REQUIREMENTS, SEE SITE PLAN FOR                                                                                                                                                       TRANSPIRE CONSTRUCTIONS AND FOR THE PURPOSE EXPRESSLY
                                                                                  SECTIONAL VIEW OF DRIVEWAY ON SLOPING SITES.
                                                                                  - DRVEWAY AND FOOTPATH CROSS OVER BY OWNER.                                                                                                                                                         NOTIFIED BY THE AUTHOR. NO OTHER PERSON MAY USE THESE PLANS.

    Copyright Notice: All house plans produced by the builder/designer Notes:                                                              Madden Developments Pty Ltd
                                                                                                                                                                               Client                         Drawing name:
                                                                                                                                                                                                                                                           N   REVISION      R2                                      Wind class: Flood level:   Scale:
    and the information contained within these documents are the exclusive
    property of the builder/designer. These house plans cannot be copied
                                                                                  UPGRADE ITEMS SHOWN IN RED                                   ABN: 52 169 872 486
                                                                                                                                              QBSA Lic No: 1284666
                                                                                                                                                                               Kellie Wilks                   Notes Page                                       CONSTRUCTION PLAN SET 14/10/22
                                                                                                                                                                                                                                                               R1 MARK UPS 02/11/22
                                                                                                                                                                                                                                                                                                                     N3            TBC                   @A3
                                                                                                                                                                                                                                                                                                                                                         @A2
                                                                               Dimensions shall not be obtained by scaling. All                                                Project                        Project status:                                                                                        Soil class:   BAL:
    or reproduced, in part or in whole in any form or by any method without                                                                                                                                                                                    R2 MARK UPS 09/11/22
    the express written consent of the builder/designer. The house plans dimensions are in millimeters unless noted otherwise.                                                 LOT 11 #12 ROBIN PLACE, LAKE   CONSTRUCTION                                                                                           TBC           12.5
                                                                            Setout dimensions shall be verified on site prior to any
    provided by the builder/designer are provided to the customer with a work
                                                                                                                                       107 Sugar Road Maroochydore QLD 4558,
                                                                                                                                                 Phone: 07 5444 2521           MACDONALD, QLD 4563                                                                                                                   Plot date:                    A0.14
    limited license to construct one home only.
                                                                                 being carried out. Any problems shall be directed      Email: [email protected]                                     Design: MOD WILDFLOWER 300 Proj. No. 11ROB
                                                                                  to the builder for clarification & correction                                                                                                                                                                                      9/11/2022
GSPublisherVersion 0.73.100.100
Log in to download the original file

Appendix E - Existing Dwelling House Plans (For Information Purposes Only).pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.