Original source · versioned page text
Appendix E - Existing Dwelling House Plans (For Information Purposes Only)
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 2. The text section number identifies this passage in the reader.
3,580
3,860
DP 50 STEP DP HYBRID
PATH
1,000
FALL
CT/OVEN FS
240
DOWN
820 cs
KITCHEN CL 2700
2,650 BP
BULKHEAD TO BULKHEAD TO
1,967 - 1,610
200 1,610
PROVIDE TIMBER BEAM
BP
WIN
50 STEP O/H CABINETS- HYBRID
afw over
2,030BP
O/H CABINETS- OVER & TO SIDE OF
DOWN 2260 AFL MW DW DR
HYBRID 2260 AFL DOOR FOR FUTURE
70 695
GUTTER WITH DOWPIPE
POST
4,450 KIT
BARN DOOR
DOOR
11 0 0 D E E P
140
1,830 - 2,970 afw over
ISLAND
4,010
SPREADER OVERHEAD
4,010
SEAT OVER 3DR
40mm STONE
70
5SH + SH OVER
+3 HOOKS 2,200 x 1,200
TOP TO ISLAND
70
70
70
ALFRESCO CEILING LINED DROP ZONE
50 STEP
RAKED CEILING TO
DINING
PORCH
ENTRY
PORCH
ENTRY
1,400
1,400
1,400
WITH PLASTER TO
1,200
DOWN
1,660
24- 60 asd (oxxxxo)
CL 2700
8,160 LIVING/DINING
HYBRID
PORCH
8,230 ALFRESCO
1,730
UNDERSIDE OF TRUSSES - HYBRID
SOFFIT & BEAMS TO BE TILES
70
LINED WITH FC SHEET FALL
9,230 ALFRESCO
POST
POST
17,470
17,470
8,230
2,200 x 1,640
140
140
7,920
70
70
8,160
ALFRESCO 820
POST
90
90
DISCLAIMER NOTE: TILES
470
140
1,830 - 2,970 afw over
The builder/designer has identified that occasionally floor framing G PROVIDE TIMBER MH PORCH CEILING
FALL LIN
elements may obstruct the ability to install services in accordance CEI BEAM OVER & TO
ED LINED WITH FC
2,440 - 4,860 Panel Lift Door
SIDE OF DOOR FOR
with relevant Australian Standards. RAK
FUTURE BARN DOOR SHEET TO
4,000 MEDIA
The use of plastered bulkheads below flooring systems may be UNDERSIDE OF
3,940
3,940
required to avoid obstructions. MEDIA TRUSS
LIVING
4,860 DOOR
Creating bulkheads is at the discretion of the onsite Supervisor, HYBRID
HYBRID
to allow contractors to ensure that all works are carried out to
meet with relevant building codes.
Final air conditioning, vacumaid, intercom and alarm GARAGE
9,000 GARAGE
1,800 - 910 1,800 - 910
design/system is to be carried out by suitably qualified CONCRETE
POST
POST
asw
140
140
asw
9,140
contractors on-site, inclusion or exclusion of ceiling vents maybe
8,740
24- 60 asd (oxxxxo)
70
70
70
70
required and whilst the builder endeavours to replicate as per the DP DP DP
FALL
TAP DP
build plan this is not always possible.
PATH
PATH
1,000
1,000
855
140x140 CAPPED WASTE HOT/COLD WATER 450 450
2,440 - 2,430 Panel Lift Door
70 910 1,680 910
TIMBER POST POINT FOR FUTURE CONNECTION & GAS WIN WIN
BBQ SINK POINT FOR FUTURE
4,650
4,580
2,430 DOOR
BBQ AREA (KEEP CLEAR
FROM GPO) FALL
A
C:\Olivet Design\1. HOMES IN DESIGN\STROUD HOMES\PROJECTS\2022\LOT 11 #12 ROBIN PLACE, LAKE MACDONALD - 11ROB\CADS\LOT 11 #12 ROBIN PLACE.pln
A0.5
DOOR
50 STEP
820
90
DOWN
70 385
70
70
70
DP DP
70 9,180 DINING/KITCHEN 90 2,450 BP 70 1,550 70 5,030 RUMPUS 70 950 LIVING AREA: 254.10m²
DROP
450 140 4,260 70 11,370 4,920 ENTRY 70 3,100 PORCH GARAGE AREA: 55.50m²
POST PORCH: 11.3m²
4,850 ALFRESCO 70 6,900 LIVING 70 4,400 MEDIA 70 6,000 GARAGE 70 1,810 140 ALFRESCO AREA: 36.20m²
POST
11,260 11,440 6,140 1,000 950 TOTAL FLOOR AREA: 357.10m2
1,000 30,790 ALF EXT & PATH: 35.60m²
Floor Plan
Scale 1:100
APPROVED
This plan is certified for compliance with the requirements
of the BUILDING ACT 1975, the BUILDING
REGULATION 2006, and attached approval conditions.
2022-4454
REFER DECISION NOTICE
Project BA
Scale 1:100
0 1 2 3 4 5 6 7 8 9 10m
Copyright Notice: All house plans produced by the builder/designer Notes: Madden Developments Pty Ltd
Client Drawing name:
N REVISION R2 Wind class: Flood level: Scale:
and the information contained within these documents are the See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.