Appendix E - Existing Dwelling House Plans (For Information Purposes Only)
Plans and drawings: the text below has words only, no drawings.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
The proposed building is located within a
Designated Bushfire Prone Area and shall
TO SCALE ON A2
be constructed to meet the Deemed to
Satisfy Provision of Part 3.10.5 of the
National Construction Code Series 2019
and AS3959-2018 for a BAL12.5.
22.50°
SHEET ROOFING 22.50°
SHEET ROOFING
UPSTAND AS
REQUIRED FOR UPSTAND AS
DEPTH OF REQUIRED FOR
450 450 450
RAFTER TRUSS 450 450 450 450 DEPTH OF
RAFTER TRUSS
UPSTAND
250
F F TP
TP FCL JOINERY F F TP FCL
JOINERY
JOINERY JOINERY
2,990
2,740
2,740
2,700
2,700
2,400
2,400
2,100
2,100
FFL FFL
310
310
PANEL LIFT ENTRY DOOR STYLE 140x140 TIMBER FEATURE ALUMINIUM JAMES HARDIE ALUMINIUM 140x140 TIMBER JAMES HARDIE
GARAGE DOOR TO BE SELECTED POST WEATHERTEX JOINERY CHAMFER BOARD JOINERY POST CHAMFER BOARD
CLADDING CLADDING CLADDING
Front Rear
Scale 1:100 Scale 1:100 Surface water drainage (including stepdowns) is to be
NOTE: provided in accordance with Part 3.1.3.3 of the National
-ALL OVERHANGS ARE DIMENSIONED Construction Code Series 2019.
FROM OUTSIDE OF TIMBER FRAME
-JOINERY HEIGHTS TO BE 2100 AFL U.N.O.
SHEET ROOFING 22.50°
450
450
UPSTAND AS
REQUIRED FOR
DEPTH OF
RAFTER TRUSS 450 450 450
UPSTAND
250
TP FCL
JOINERY
140x140 TIMBER
2,740
2,700
POST
2,100
FFL
310
140x140 TIMBER GARDEN ALUMINIUM JAMES HARDIE FEATURE
POST TAP JOINERY CHAMFER BOARD WEATHERTEX
CLADDING CLADDING
Lhs
Scale 1:100
SOLAR PV PANELS -NUMBER AND
LOCATION TBC BY INSTALLER
22.50°
450 SHEET ROOFING
450 450
C:\Olivet Design\1. HOMES IN DESIGN\STROUD HOMES\PROJECTS\2022\LOT 11 #12 ROBIN PLACE, LAKE MACDONALD - 11ROB\CADS\LOT 11 #12 ROBIN PLACE.pln
TP FCL
JOINERY
2,740
2,700
2,100
140x140
ON
ITI
TIMBER
IGN
OPENINGS
POST
FFL
310
FEATURE ELECTRICAL GARDEN PIG TAIL GAS ELECTRICAL HOT ALUMINIUM AIR CONDITIONING WALL MOUNTED
WEATHERTEX METER TAP CONNECTION. FUTURE WATER UNIT JOINERY UNIT CLOTHES LINE
CLADDING GAS BOTTLES BY CLIENT
APPROVED Rhs
This plan is certified for compliance with the requirements
of the BUILDING ACT 1975, the BUILDING Scale 1:100
REGULATION 2006, and attached approval conditions.
2022-4454
REFER DECISION NOTICE
Project BA
Copyright Notice: All house plans produced by the builder/designer Notes: Madden Developments Pty Ltd
Client Drawing name:
N REVISION R2 Wind class: Flood level: Scale:
and the information contained within these documents are the exclusive
property of the builder/designer. These house plans cannot be copied
UPGRADE ITEMS SHOWN IN RED ABN: 52 169 872 486
QBSA Lic No: 1284666
Kellie Wilks Elevations CONSTRUCTION PLAN SET 14/10/22
R1 MARK UPS 02/11/22
N3 TBC 1:100 @A3
@A2
Dimensions shall not be obtained by scaling. All Project Project status: Soil class: BAL:
or reproduced, in part or in whole in any form or by any method without R2 MARK UPS 09/11/22
the express written consent of the builder/designer. The house plans dimensions are in millimeters unless noted otherwise. LOT 11 #12 ROBIN PLACE, LAKE CONSTRUCTION TBC 12.5
Setout dimensions shall be verified on site prior to any
provided by the builder/designer are provided to the customer with a work
107 Sugar Road Maroochydore QLD 4558,
Phone: 07 5444 2521 MACDONALD, QLD 4563 Plot date: A0.4
limited license to construct one home only.
being carried out. Any problems shall be directed Email: [email protected] Design: MOD WILDFLOWER 300 Proj. No. 11ROB