Original source · versioned page text
Appendix A - Proposal Plans.pdf
2 2
S
S
2 2 2 2
2 2 2
2 2
S
S
2 2 UP 2 2
2
2 2 2
2
2 S
2
S 2 2 2
S 2 2 2 2
LEGEND Electrical Plan
LIGHTING POWER 1 : 100
External Garden Uplight A Connection to Rangehood Fan & Lights GENERAL NOTES
External Surface Mounted Light B Connection to Gas & Electrical Gas Stove 1. Location of fixtures and wiring devices are indicative - Group adjacent
outlets and switches together in mounting boxes, mounting frames and
F External Surface Wall Mounted Light - Type F C Connection to Electrical Oven cover plates where possible. Refer to internal elevations for exact
D Connection to Dishwasher under bench locations of fixtures where applicable.
H Internal Surface Wall Mounted Light - Type H 2. Surge protection to be provided.
2 Single/Double/Quadruple GPO (10A) Number Denotes 3. Smoke Alarms to be Photoelectric and Hardwired to Mains Power
LED Downlight
Sockets Per Plate. Installed at 300mm above FFL or 150mm
A LED Pendant Light - Type A above bench where indicated. (AB - Denotes above bench BB
- Denotes below bench). Provide safety switched power points
B LED Pendant Light - Type B to Bathroom, Laundry, Garage and Kitchen.
WP2
LED - Fluorescent Undercupboard Light GPO - Double - Waterproof
LED - Fluorescent Vanity Light Meter Board - May be located other than
shown, on approval. COMMUNICATIONS OTHER
SL LED - Spotlight
S Smoke Alarm to be Photoelectric and Hardwired to Mains Power
CAT 6 Data Outlet
LC LED - Lighting Control Motion Detector Switch Ceiling Fan with
Pay TV Antenna 1400mm Diameter
Slimline Linear Fluorescent - Double D Switch - Dimmer
Television Socket
FC Switch - Fan Controller
LED Light / Exhaust Fan Ceiling Mounted 2W Telephone Socket Ceiling Fan with
Switch - Two Way
1800mm Diameter
WP Switch - Waterproof USB Socket
PRELIMINARY DRAWINGS NOT FOR CONSTRUCTION ELECTRICAL PLAN
Smart Building Designs Residential Dwelling Renovation Project No. 26-408
The design illustrated in these documents is the exclusive property of
47 Mahogany Drive, Marcus Beach. Brett Fawcett
Steve Campbell Design ABN 273 268 414 32 and must not be reproduced A
without the expressed written permission of Steve Campbell Design.
A Issued For Development Approval 14/04/2026 Ph: 0428 762230 QBCC Lic No.1170438 Drawn by Scale 1 : 100 A390
No. Revision Date www.stevecampbelldesign.com.au 87 Eumundi Road, Noosaville. QLD. SC Date 26/03/2026 Revision