Original source · versioned page text
Attachment 1 - Proposal Plans.pdf
INDICATIVE PLANTING SCHEDULE
A.
PHYLLANTHUS
MULTIFLORUS
'WATERFALL PLANT'
INDICATIVE LOCATION OF ABOVE GROUND/ B.
INDICATIVE LOCATION OF NEW BELOW GROUND SURFACE MOUNTED PIPEWORK TO NEW BOOSTER CISSUS ANTARCTICA
PIPEWORK TO NEW DUAL FIRE HYDRANT AND ASSEMBLY SHOWN IN DIAGONAL HATCH 'KANGAROO VINE'
BOOSTER ASSEMBLY, SHOWN IN CROSS HATCH
INDICATIVE LOCATION OF EXISTING POOL
EQUIPMENT TO REMAIN SHOWN DASHED
RELOCATED FIRE HYDRANT BOOSTER
37
'C' ASSEMBLY
.
35
C.
'A'
SL
'B' CABLE TRELLIS
7
NEW RAISED PLANTER BED 3 .6 TO WALL
WALLS, TOP OF WALL HEIGHT 'A' 3
TO MATCH EXISTING SL
5
.4
34
'A'
REINSTATE PLANTING TO MODIFIED 1M CLEARANCE ZONE
SL
AROUND PUMP
5
RAISED PLANTER, REFER TO
.4
34
INDICATIVE PLANTING SCHEDULE 2
SL 32.9 RELOCATED DUAL FIRE HYDRANT
SL
3
5
.7
NEW FIRE PUMP ENCLOSURE
.4
0
32
SL 32.93 m
34
.8
32
SL 32.82 m
SL
9
SL
.8
SL
1
32
.1
35
SWMH
SL
SEMH
SL
SITE BOUNDARY
TREE
TREE
SEWER UG (CLASS D)
TELECOMMS UG (CLASS D)
ELECTRICITY UG (CLASS D)
8
8
.9
.6
1
32
31
B DA Issue 27.03.26
SL
SL
A Fire pump updates DV 12.02.26
A200.04 issue revision initials date
NOOSA DRIVE Cayas
+ Ward
WATER UG (CLASS D)
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
client ALH Group
SL 32.05 m
project Noosa Reef Hotel
Proposed Part Plan 19 Noosa Dr, Noosa
1
SWMH
Heads QLD 4567
1 : 100 drawing title Proposed Plan
RL 31.627 m
drawn RH
Stn 902
date NOV 2025
scale As indicated@A3
project no. drawing number issue
2395 A200.03 B
[OCR of page images]
INDICATIVE PLANTING SCHEDULE
ma
A.
PHYLLANTHUS
MULTIFLORUS
‘WATERFALL PLANT'
INDICATIVE LOCATION OF ABOVE GROUND/ 2 ogg. B
INDICATIVE LOCATION OF NEW BELOW GROUND SURFACE MOUNTED PIPEWORK TO NEW BOOSTER | 2a .
PIPEWORK TO NEW DUAL FIRE HYDRANT AND ASSEMBLY SHOWN IN DIAGONAL HATCH
BOOSTER ASSEMBLY, SHOWN IN CROSS HATCH
INDICATIVE LOCATION OF EXISTING POOL
/ EQUIPMENT TO REMAIN SHOWN DASHED
/
RELOCATED FIRE HYDRANT BOOSTER
ASSEMBLY
Cc.
CABLE TRELLIS
NEW RAISED PLANTER BED TO WALL
WALLS, TOP OF WALL HEIGHT
TO MATCH EXISTING
REINSTATE PLANTING TO MODIFIED
RAISED PLANTER, REFER TO
INDICATIVE PLANTING SCHEDULE
NEW FIRE PUMP ENCLOSURE
TELECOMMS UG (CLASS D)
B DA Issue 27.03.26
A Fire pump updates DV _ 12.02.26
issue revision initials date
NOOSA DRIVE
_ “project [Noosa ReefHotel =
(4) Proposed Part Plan _ 19 Noosa Dr, Noosa
\ Heads QLD 4567
Ny, 1: 100 drawing title |Proposed Plan
Cayas
oS +Ward
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
client ALH Group
WATER UG (CLASS D)
draw]JRH
4 date | NOV 2025
scale | As indicated@A3
roject no. drawing number _issue
2395 A200.03 B
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment 1 - Proposal Plans.pdf)