Original source · versioned page text
Compiled Approved Plans & Reference Document - 132007.12.9
Plans and drawings: the text below has words only, no drawings.
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
DRAWING STATUS:
DA Submission
Rev Revision Description Date
1 Client Approved DA Submission 19/12/2022
2 Additional information 13/02/2023
3 Approved DA Submission 23/02/2023
©Copyright Team 2 Architects
This drawing is protected by copyright. All right are reserved. Unless permitted under the
Copyright Act 1968. No part of this drawing may in any form or by any means be
reproduced, published, broadcast or transmitted without the prior written permission of the
copyright owner. Please Note: If the status of this drawing is not signed off For
Construction it may be subject to change, alteration or amendment at the discretion of
Team 2 Architects. If so, Team 2 Architects is not liable for any loss, damage, harm or injury
whether special, consequential, direct or indirect, suffered by you or any other person as a
result of your use of this drawing for construction purposes.
DRAWING LEGEND:
1. Architectural drawings shall be read in conjunction with other consultant drawings
and specifications. Any discrepancies shall be referred to Team2 Architects before
proceeding with work.
2. All dimensions and levels are in millimeters unless noted otherwise. No dimension
shall be obtained by scaling the drawing.
3. All dimensions to be checked on site with any discrepancies referred to Team2
Architects before proceeding with work.
4. All work to be carried out in accordance with the requirements of the principal
certifying authority, NCC relevant to this project & Australian Standards.
5. Clouds reflect changes since previous revision; reversed clouds reflect area or item
on hold/pending input or confirmation.
EUMUNDI ROAD
GOODCHAP STREET
ROUNDABOUT
CHILDCARE CENTRES
SHOWN SHADED
3541
(SUBJECT TO SEPARATE APPROVALS) 98 99 100 101 102 103 104 105 106 107 108 109 110 111
89 90 91 92 93 94 95 96 97
285
Carpark - 65 spaces 122
Motorbike - 1 space 123
286 Ambulance - 1 space
124
AMBULANCE 125
Carpark - 5 spaces
THE 5 CAR SPACES
LOADING 118 119
APPROVED UNDER 287 112 113 114 115 116 117 120 121 126
Outdoor Seating 83 84 85 86 87 88
CONDITION 65 127
DA 132007.12.6. 131 128
288 lift well 132 129 INDICATIVE TENANCY FITOUT SHOWN
133
130
134 16M
1.01 1.02 1.03 1.04 1.05 763.71 sq.m NEW AUTO SLIDING DOOR IN
289 135
220 sq.m 180 sq.m LIEU OF EXISTING DOOR
100 sq.m 44 sq.m PEDESTRIAN
+16 sq.m for outdoor 136 CROSSING
seating INCLUDES ADDITIONAL 66
USE AREA 137 138 92 CK
DISABLED TBA
SE
PROPOSED BUILDING EXTENSION
ADDITIONAL USE AREA 110 sq.m
179 178 177 176 175 174 173 172 171 170 169 168 165 164 163 162 161 160 159 158 157 156 155 154
ON
167 166
EW
DISABLED DISABLED
AY
14M
carpark - 51 cars RL 9.3
1 2 3 4 5 6
Ambulance 7- 1 space 8 9 10 11 12
1.13 1.12 1.11 1.10
1.14 77 sq.m 77 sq.m 77 sq.m 77.6 sq.m
RL 8.00 RL 8.15
8
RL 9.14 RL 9.27 RL 9.32
8.5 RL 9.32 RL 9.27 RL 9.14 9 RL 8.85
RL 8.66
1.15 48 sq.m SB
139
RL 9.10 AMBULANCE RL 9.10
1.16 75 sq.m
SB
15M
191 192 193 194 195 196 197 198 199 200 201 202 203 204
SB SB
180 181 182 183 184 185 186 187 188 189 190 LOADING
DISABLED DISABLED
1 1.17 76 sq.m 72 sq.m SB
SB
CAR PARKS ROTATED
7.5
78 sq.m SB
SB
A RL 7.33 RL 7.43
RL 8.25 dp dp RL 9.25
dp RL 9.25
dp dp RL 9.45 RL 9.45
RL 9.45
RL 9.45 dp dp RL 9.25 dp dp dp RL 9.25 RL 9.15
2 SB
RL 8.26
140
3
4475
RL 9.45
141
RL 8.41
205 Carpark - 6 spaces ONE WAY
142
B
Carpark - 12 spaces 4 Motorbike - 1 space 149
143
206 151 150 148 147 146 145 144
5
207
8050
8.5 152
6 L O AD I N G AREA
208 153
C
7
209 ADDITIONAL USE AREA
lift
23 sq.m
RL 9.45
cleaner 210
FFL 9.5 FFL 9.5
8950
RL 7.65
6.5 shr 8 THE COMBINED LOADING/CAR
1000 sqm 750 sqm RL 7.80
PARKING APPROVED UNDER
APPROVED UNDER DA
shr
Overall 132007.12.6.
D unisex CONDITION 34, DA 132007.12.6.
6
EXISTING AMENITIES
8050
female
LOADING BAYS BETWEEN ACCESS UNALTERED
mal e 7.5 8 a.m. AND 11 a.m.
7.5
E dp PLAN LEGEND
4475
7
NO WORKS TO BE CARRIED
F
5.5
OUT IN THIS AREA
3190
6.5
site set out point
5.5
6
EXTENT OF ADDITIONAL
7357
1
5800
2
5800
3
5800
4
5800
5
5800
6
5800
7
5800
8
5800
9
5800
10
5800
11
5800
12
USE AREA
Proposed Tenancy Ground Floor
1 Scale: 1 : 500
Level 25, Australia Square 264-278 George Street,
Sydney
0 5 10 20 See the original