Original source · versioned page text
Compiled Approved Plans & Reference Document - 132007.12.9
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
DRAWING STATUS:
DA Submission
Rev Revision Description Date
1 Client Approved DA Submission 19/12/2022
©Copyright Team 2 Architects
This drawing is protected by copyright. All right are reserved. Unless permitted under the
Copyright Act 1968. No part of this drawing may in any form or by any means be
reproduced, published, broadcast or transmitted without the prior written permission of the
copyright owner. Please Note: If the status of this drawing is not signed off For
Construction it may be subject to change, alteration or amendment at the discretion of
Team 2 Architects. If so, Team 2 Architects is not liable for any loss, damage, harm or injury
whether special, consequential, direct or indirect, suffered by you or any other person as a
result of your use of this drawing for construction purposes.
DRAWING LEGEND:
1. Architectural drawings shall be read in conjunction with other consultant drawings
and specifications. Any discrepancies shall be referred to Team2 Architects before
proceeding with work.
2. All dimensions and levels are in millimeters unless noted otherwise. No dimension
shall be obtained by scaling the drawing.
3. All dimensions to be checked on site with any discrepancies referred to Team2
Architects before proceeding with work.
4. All work to be carried out in accordance with the requirements of the principal
certifying authority, NCC relevant to this project & Australian Standards.
5. Clouds reflect changes since previous revision; reversed clouds reflect area or item
on hold/pending input or confirmation.
Landscaping in accordance with approved Landscaping Plan
CHILDCARE CENTRES
SHOWN SHADED Landscaping in accordance with approved Landscaping Plan
(SUBJECT TO SEPARATE APPROVALS)
A
lift well
lift RL 7.0
lift well
B 2.01 2.02 2.03 dp 2.04 2.05 2.06
150 sq.m 239 sq.m 50 sq.m 134 sq.m 137 sq.m 495 sq.m
C dp
PROPOSED
BUILDING
L
sink unit
Sink Unit
wc wc wc wc
Disabled
EXTENSION ROOF
Male Fem
dp WC
D sink unit
FHR
M
E
sta
ir 2
1 2 3 4 5 6 7 8 9 10 11 12
Roof Below
F
Stairs below dp
G 14
A
dp
dp dp dp dp dp dp 13
4475
Stage 1 Stage 3 UPPER LEVEL FLOOR PLAN
B Scale 1 : 100
12
6 7 8 9 10 11
1 2 3 4 5
8050
POTENTIAL PLANT
C
female
LOCATION
mal e
lift
Sink Unit
Sink Unit
unisex
8950
D
TOTAL FLOOR AREA
1600 sq.m
8050
LOW ROOF BELOW
E
PLAN LEGEND
NO WORKS TO BE CARRIED
4475
5800
12
F
OUT IN THIS AREA
3190
EXTENT OF ADDITIONAL
site set out point
USE AREA
7357 5800 5800 5800 5800 5800 5800 5800 5800 5800 5800
1 2 3 4 5 6 7 8 9 10 11
Level 25, Australia Square 264-278 George Street,
Sydney
DA - Upper Level Floor Plan
1 Scale: 1 : 500
0 1 2 3 4 5
SCALE 1:100
[email protected] ABN: 72 104 833 507
SYDNEY MELBOURNE
Lvl 1, 45 Chandos Street, 204/9-11 Claremont St,
St Leonards NSW 2065 South Yarra VIC 3141
T: + 61 2 9437 3166 T: +61 3 8849 9137
Reg NSW: 9940 Reg Vic: 19340
Project:
Noosa Medical and Professional
Centre
90 Goodchap St, Noosaville QLD
Title:
PROPOSED OVERALL UPPER PLAN
NOOSA COUNCIL Project #: Scale: Drw: Ckd:
APPROVED PLAN 1124 1 : 500 @A1 MM DB
Drawing #: Rev:
132007.12.9 15 JUNE 2023