                                                                               CONSTRUCTION OF DRiVewAY
                                                                               CROSSOVER TO BE IN ACCORDANCE WITH                          UNIT BLOCK A FINISHED FLOOR LEVELS                                                          Drive
                                                     Hofmann Drive             LOCAL AUTHORITIES REGULATIONS IREFER TO
                                                                               CIVIL ENGINEERS DETAILSI
                                                                                                                                           UNTfSOI-07                                                                        Hofmann
                                 Lot 5
                            (SP222982)
                            BUSHLAND
                                         UNIT BLOCK D FINISHED FLOOR LEVELS
                                         UNTfS 26 30
                                                 -
                                         GROUND LEVEL TOP OF SLAB R.L. 4.950
                                         FIRST LEVEL TOP OF FLOOR R.L. 8.00
                                         UNIT BLOCK C FINISHED FLOOR LEVELS
                                         UNTfS 20 25
                                                 -
                                         GROUND LEVEL TOP OF SLAB R.L. 4.535
                                         FIRST LEVEL TOP OF FLOOR R.L. 7.585
SEDIMENT CONTROL MEASURES TO BE TAKEN ON SITE DURING
CONSTRUCTION
FINAL LANDSCAPING TO BE DESIGNED BY LANDSCAPE
ARCHTfECT
ALL GLAZING WITHIN 10m FIRE ZONE TO BE IN
ACCORDANCE WTfH THE REQUIREMENT OF AS 3959
METAL FENCING TO BE FLUSH TO TOP OF RETAINING WALL.
SO AS TO NOT ALLOW POTENTIAL EMBER TO PASS THROUGH
                                         8Y
8UILDER/CLlENT PRIOR TO COMMENCEMENT.
-
    CUT & FILL BAnERS INDICATIVE ONLY
                                                          ~
-
    PLATFORM/AND OR TOP OF SLAB LEVElS
    TO BE CONFIRMED ON SITE
-LOCATION OF EASEMENTS
-SEWER LINE
-
    BUILDING COVENANT SITE REQUIREMENTS
-
    DESIGNATED BUILDING ENVElOPES
-
    SPECIAL HEIGHT RESTRAINTS BY COUNCIL OR DEVELOPER
-
    SITE BEARINGS & DIMENSIONS
                                                                                                                                 Client.
                                                                                                                                 Canto Holdings P/L                                                                                                 Supplement
                                                                                                                                 Lot 4 Hofmann Drive
                                                                                                                                 NOOSAVILLE                                                                     Builder. J. & G. KNOWLES & ASSOCIATES (07)334
                                                                                                              design to enjoy.                                                                                www.rellsma.com.au P: 07 54916834 PO Box 3515 Coloundra QLD 4551 Pazcol Pt




                                                                                                                                                                            SUNSHINE COAST REGIONAL COUNCIL



                                                                                                                                                                                                                         17 Aug 12
                                                                                                                                                                                                              APPROVED
                                                                                                                                                                                                                         11/0254
                                                                                                                                                                                                                         MCU

Used in these records

About this file

File size
40.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPROVED PLANS - MCU11_0254.pdf · 40.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.