Skip to the record
Noosa's #1 Council Tracker.

Original source · versioned page text

Annexure A to Order 22Aug2022 - Conditions and Plans

of 99

Page text shows just the words. Original shows the document exactly as it was published.

Very large file: it may take a few minutes

The original of this document is very large (31.5 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 14, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
           GENERAL SPECIFICATION                                                                                                                           Construction Notes
   ALL BUILDING WORK TO BE CARRIED OUT TO THE BUILDING CODE OF AUSTRALIA & THE BUILDING ACT 1975.                                       Timber Frame: Framing to be built in accordance with AS 1684 Termite protected timbers shall be used on all framing
   BUILDER TO SUPPLY FOOTPATH PROTECTION & REQUIRED SIGNS TO COMPLY TO WORKPLACE HEALTH & SAFETY ACT.                                   Approved type flashing & sarking to be attached between cladding & frame along with slab & frame to prevent moisture
   PRINCIPLE CONTRACTOR TO HAVE A SITE SPECIFIC WORKPLACE HEALTH & SAFETY MANAGEMENT PLAN TO COMPLY WITH                                getting to the frames
   GOVERNMENT REGULATIONS TO BE KEPT ONSITE & GIVEN TO ALL CONTRACTORS
   WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALE.                                                                                    All wet areas to be made waterproof or resistant to comply to AS 3740 & BCA 3.8.1
   BUILDER TO VERIFY ALL SET-OUT DIMENSIONS PRIOR TO PLACEMENT OF CONCRETE                                                              Linings used shall be approved for use in wet areas & shall be fixed in strict accordance
   BUILDING MUST COMPLY WITH THE NATIONAL CONSTRUCTION CODES (BCA) & THE QUEENSLAND HOME BUILDING CODE                                  with Manufactures specifications.
   ALL CONCRETE SLABS & FOOTINGS TO COMPLY WITH (AS 2870)                                                                               Wet Areas include Laundry
   ALL STRUCTURAL TIMBERS TO COMPLY WITH NATIONAL TIMBER FRAMING CODES (AS1684.2 &AS1720) & CONSTRUCTION TIMBERS
   IN QUEENSLAND (CTIQ)                                                                                                                 All walls to be checked to ensure they are fixed correctly, straight & plumb prior to fixing plasterboard or interior lining
   TERMITE PROTECTION TO (AS3660.1) CERTIFICATES TO BE SUPPLIED & GIVEN TO CERTIFIER                                                    Plasterboard or interior linings to be fixed to dry frames in strict compliance with manufactures details. Setting of
   ALL WET AREAS TO BE WATERPROOFED, INTERNAL WATERPROOFING TO COMPLY TO (AS 3740) AS IN BCA 3.8.1                                      plasterboard to be done in strict compliance with manufactures specifications, Sanded to provide a flat smooth finish
   ALL GLASS TO COMPLY TO (AS 1288) WINDOWS & DOORS ALONG WITH SCREENING OR SECURITY SCREENS TO COMPLY TO
   RELEVANT REGULATIONS                                                                                                                 Painting: Paints & application to comply to AS 2311 Min 3 coat application system to be used
   PLASTERBOARD TO (AS 2589), PAINTING TO COMPLY TO (AS 2311) TILING TO COMPLY TO (AS 3958)                                             Substrate to be clean & dry correct type sealers & primers to be used for substrate
   STAIRS TO COMPLY TO BCA 3.9.1 BALUSTRADE TO COMPLY TO BCA 3.9.2,                                                                     If paint is sprayed on then a back roll should be done between coats & after final coat
   WIND CLASSIFICATION (N3).                                                                                                            Mould resistant paint to be used in Bathrooms, Ceilings to have approved ceiling paint applied & be a matt finish

                                                                                                                                        Concrete slabs & footings to be poured AS per Plans & in accord with AS 2870
                                                                                                                                        Slabs shall be finished to suit floor coverings

                                                                                                                                        All external windows & doors to have appropriate flashing & seals fitted to prevent water getting into building or
                                                                                                                   -                    to the frame work
                                                                                                          NOOSA COUNCIL
                                                                                                         APPROVED PLANS
                                                                                                     51983.3225.03 11 NOV 2014




Not for construction or certification
Client: Alison Payne      Unit 22 The Hastings Noosa Parade Noosa Heads                   Wind Classification N3                                                                                                                            Date      22/07/2014 6:25:40 AM
                                                                                                                       ACCOLADE Building Designs
RPD: Lot 22 on GTP 1154         Parish: Weyba       County: March       Site Area : 105 m²                                Proprietor: Steven Horn                                   Mobile: 0407 693 018          Drawn for A3 Sheet
Proposed Partial Enclosure of Ground Level Under Unit                                                                                                                        Email: [email protected] Scale      Sheet No. 1 of .
                                                                                                                                                                                                                                                                        14
Log in to download the original file

Annexure A to Order 22Aug2022 - Conditions and Plans.pdf · 31.5 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.