Original source · versioned page text
Approved Plans
Leone
UPS IL fl 44
7S \L 1/40. Jar
Ort EXT
3-60077 RE
HEAD WALL
COMMUNITY
CENTRE
LEGEND
EXISTING CONTOURS ——————_—
PROPOSED STORMWATER DRAINAGE sesso se —s{)o— ssn
PROPOSED SEWER LINE
APARTMENTS
STRUCTURE NUMBERS
INFILTRATION/STORAGE PIPES
REFER DRG MI717-DO8
CONSTRUCTED STAGES IA @IB
STAGING BOUNDARY eee eee
NOTE
1. ALL PIPES TO BE RUBBER RING JOINTED.
OSs
ft
ease (MODEL BGPCT]
SHINE COAST REGIONAL GO
PPROV
[|
0 9\5 2f
SLOPE WINGWALL
BACK AT 1 in |
EXTEND 3 - 600?
PIPES TO HEADWALL
CULVERT. §
i
CULVERT LAYOUT
SERVICES STRAPED TO TOP OF
WALL OVER CULVERT TO CULVERTS WITHIN CONDUITS
ARCHITECTS DETAILS
2.0m
OUTLET DETAILS.
MRD STD DRG 1303
WINGWALL FLARE - 45° & 30°
TYPE 3 APRON
IL_1.40
U
DESIGN CALCULATIONS
DESIGN Q - 8.7cumecs
CULVERT SLOPE - 0.33% CULVERT
TAIL WATER DEPTH - 0.
HEAD WATER DEPTH - 1500 wide x 1200 high RCBC with
OUTLET VELOC! 1800 wide spanning slab between.
Length - 12.0m
1:10 150 41 2003 4 Sat
12 43
FOX BAFFLED GROSS POLLUTANT COLLECTION TRAPS
STD NSC GULLY PIT
3757 RCP PIPE
D/S IL
~ LENGTH 16.9m
INLET DETAILS.
MRD STD DRG 1303
WINGWALL FLARE - 45° & 0?
TYPE 3 APRON
SI vo “ye (0 _ [ROAD 2 REALIGNED. 4a VOMOVED aioe | “y"
C) dcr) 1 Consulting Engineers N 1500 0 50 10 20 at " sheet 1 of2 sheets
development consultants, planners and surveyors nop; = _| STAGING BOUNDARY ADDED az [|] NOOSA DOMAIN RETIREMENT VILLAGE ,
JF & P CONSULTING ENGINEERS PTY. LTO. ABN 77.050 414 036 ‘ = drawing number
eueraee che 0 NOT SCALE FROM THIS DRAYING-USE ONLY ONENSIONS PROVIDED DOUBT PLEASE ENauNRe ‘ALT: AHO drhod an (BM) F | pporionat = TAL er |S) GOUNTRY CLUB VILLAGES PTY. LTD s
Fee eg tah cen | designed | sat | COPYRIGHT © 2005 JF & P CONSULTING ENGINEERS PTY. LTD. ‘ment | reislon dete date | tit |__| GROSS POLLUTANT TRAP DETAILS AMENDED zaoao7 | sun : . M1717-D02 |
fojaline (01) 448 2500 Ueboptiar (714872200) drawn | aM | THis DOCUMENT MAY NOT BE COPIED OR TRANSMITTED IN ANY | ORIGINAL ISSUE 232068 | a | H [ROAD 12REALIGNED, GA WOVED aacear | GA file name
BRISBANE -UFBP House FORM OR BY ANY MEANS IN PART OR IN WHOLE WITHOUT THe
Souk Bisbone, Queensland: #101 checked | AF | WRITTEN aor “JF & P CONSULTING ENGINEERS PTY. LTD. B _| INFILTRATION PIPES MOVED ROAD 4 20606 | aM | 1 | CONSTRUCTED STAGES SHOWN taoii2 | sop = M1717-D01-D07,.WG
telephone (07) 3844 7161 Ss \approved| a Fraser... =m, wo.RPEQ 5691 __A_©_| ENTRANCE ROAD MOVED, CULVERT LENGTHENED. 67.08 MAL A
Kate 282.06 4)