Council archive · source document
09/1176 - APPROVED PLANS [As Published] · 132009.1176
Plans and drawings: the text below has words only, no drawings.
Re
2
NOTE: ae . .
") 5" * MEASUREMENTS PRIOR TO COMMENCEMENT " °° 7” re aes ie eee
| Design IN ACCORDANCE WITH THE QUEENSLAND HOME
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING
CODE'OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
GENERAL NOTES
ALL MATERIALS SHALL BE NEW.
FOOTING: TO ENGINEER DETAILS.
FOOTINGS TO HAVE SOLID BOTTOMS *
AND EVEN BEARING THROUGHOUT.
‘SLAB: TO ENGINEER DETAILS
UNDERLAY WITH 200mm POLYTHENE
WATERPROOF MEMBRANE AND ALL
PROTRUSIONS. CAST ON 50mm SAND
BEDDING ON APPROVED FILL.
CONCRETE STRENGTH TO BE 20MPa
AT 28 FAYS. USE TERMITE CONTROL
AS PER BUILDERS SPECIFICATIONS.
TIMBER FRAMING: ALL FIXINGS AS
PER CONNECTION DETAILS AND GOOD
WORKMANSHIP,
LININGS: AS PER BUILDERS SPECIFICATIONS.
ROOFING; COLORBOND METAL SHEET
ROOFING OR CONCRETE ROOF TILES
OVER AN APPROVED SARKING MATERIAL
AND FIXED IN ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS.
PLUMBER AND DRAINER: TO LOCAL
AUTHORITY REGULATIONS,
ELECTRICIAN: TO LOCAL AUTHORITY
REGULATIONS.
BRICKLAYER: GALVINISED WALL TIES
1 ROW AT 2 COURSES ABOVE FLASHING
UNE AND 1 ROW IN THE SECOND LAST
BED JOINT FROM TOP OF WALL AND @
‘500crs, IN BETWEEN ON EACH STUD.
PROVIDE WEEP HOLES @ 900crs, ALONG
FLASHING, .
ALL WET AREA FLOOR AND SHOWER FLOORS.
TO COMPLY WITH B.C.A SECTION 3.8.1,
BUILDER TO CHECK AND CONFIRM ALL
OF CONSTRUCTION. DO NOT SCALE ORAWINGS,
WRITTEN DIMENSIONS TAKE PRECEDENCE AT
ALL TIMES. STORMWATER THROUGH P.V.C.
PIPE TO LOCAL COUNCIL REGULATIONS,
APPROXIMATE SEWER
CONNECTION POINT
PROPERTY POLE TO BE
INSTALLED PRIOR TO
CONSTRUCTION. RUN
POWER UNDERGROUND TO
HOUSEHOLD METERBOX.
RAINWATER TANKS (AS PER QDC PART MP 4.2)
MINIMUM TANK SIZE - 5000m?
CONNECT TO ALL WC'S AND WASHING MACHINE COLD WATER TAPS
CONNECT TO ALL EXTERIOR TAPS
RAINHEAD TO HEAD LEAVES (WHERE APPLICABLE) - MESH SIZE 4mm-6mm
20L FIRST FLUSH DIVERTER, IF CONNECTED TO SHOWERS, WASH BASINS,
KITCHEN, HOT WATER OR REQUIRED BY LOCAL GOVERNMENT PLANNING
SCHEME.
MOSQUITO PROOF SCREENS (MAX 1mm MESH SIZE)
OP UP SYSTEM FROM LOCAL TOWN WATER
ATCHMENT AREA - 1/2 ROOF AREA or 100m*. WHICHEVER IS THE LESSER)
NOTE : ALL TREES AND
ROOTS TO BE FULLY REMOVED
50001 "SLIMLINE* WATER TANK
PLUMBED IN ACCORDACE WITH
LOCAL COUNCIL REQUIREMENTS
EXPOSED AGGREGATE
DRIVEWAY TO COMPLY WITH
. COUNCIL REQUIREMENTS
(75.0M2)
250mm MAX HEIGHT OF BATTER
WITHIN 1500mm OF BOUNDARY
ee eee
END - INTERN,
AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD.
C'BD - CUPBOARD
DP - DOWNPIPE
OW - DISHWASHER PROV,
FW- FLOOR WASTE
GAS - GAS CONNECTION
HP - HOT PLATE
HWS - HOT WATER SYSTEM
L-UNEN
MH - MANHOLE:
MW - MICROWAVE PROV, ~
OHC - OVERHEAD CUPBOARD.
PTY - PANTRY
R- ROBE
REF - REFRIOGERATOR SPACE
RH - RANGEHOOD:
SH- SHELF
TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
‘WO - WALL OVEN
FiS - FACE SLIDER.
LEGEND - EXTERNAL
BV - BRICK VENEER
BL - BLOCKWORK
CO - CUSTOM ORB SHEETING
FC - FIBRE CEMENT SHEETING
{LB - LINEA-BOARD CLADDING
RBB - RENDERED SLUEBOARD:
RB + RENDERED BRICKWORK
RAL - RENDERED BLOCKWORK
SM - SYCON MATRIX PANELING
TB - TIMBER BATTENS
WB - WEATHERBOARD (AS SPEC)
PROPERTY
. DESCRIPTION
- LOT 124 — RP48113
“PARISH: WEYBA ~
COUNTY; MARCH
AREA: | 569m2
REVISIONS,
#| DATE DETAILS
R1}03-04-09| CLIENT CHANGES:
IR] 27-04-09 CLIENT CHANGES:
R43] 13-05-09] WORKING DRAWINGS |
R4] 05-06-00] CLIENT CHANGES
17-07-08| MINOR REVISIONS
5
6 }22-07-09| BATTEN REV. TREE REI
weep we ee
po box 418 p (07) 5442 6413
coorey q4563_ (07) 5442 6549
{ QBSA 1083000
This plan remains copyright to
Ausmar Homes and may not be -=:|
used in part or in whote without ~
the written consent of the author,
© 2008 Ausmar Homes
SUNSHINE COAST
REGIONAL COUNCIL
| PLANS oe
Signature: .
vue... 25 £020
WRITTEN DIMENSIONS TO
TAKE PRECEDENCE OVER SCALE
SITE PLAN
PROJECT DESCRIPTION:
Proposed Residence For:
CLSENT:
MR W & MRS C TERRY
SITE ADDRESS:
LOT 124 PACIFIC
AVENUE
SUNSHINE BEACH
UBDREF | MAP 9, 0-20
DRAWN BY | BTOVEY
SCALE JOB CODE
4: 200
DATE WCT
2.07-08
SHEET 1 OF 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1176 - APPROVED PLANS [As Published]Related documentApplication case desk ↗
About this file
- File size
- 817 KB (small file)
- File type