Town Planning Report
Table 6.3.3.3—High Density Residential Zone Code
Performance outcomes Acceptable outcomes Response
PO9 AO9.1 Performance Outcome
Buildings and structures are designed and sited to: Buildings and structures meet the following minimum boundary Front
(a) provide a high level of amenity to users of the subject site setbacks: The following minimum setbacks are achieved to the front of the site:
and adjoining premises, including provision of visual and (d) for frontages: Ground Level – 8.6m
acoustic privacy; i. first and second storeys— 6 metres Level 1 – 7.3m
(b) not unreasonably obstruct views or cause overlooking of ii. third storey and thereafter—10 metres Level 2 – 7.3m
private open space or habitable areas of adjoining (e) Side boundaries—
premises; i. 1.5 metre setback up to 4.5 metres height; The front setback for the two lower levels comply with the
(c) provide adequate distance from adjoining land uses; ii. 2 metres setback between 4.5 metres and 7.5 prescribed setback of AO9.1. The upper level achieves a setback of
(d) preserve existing vegetation that will help buffer metres height; and 7.3m to the outer projections and 9.9m to the wall triggering
development; iii. 2 metres plus 500 millimetres for every 3 metres assessment against PO9.
(e) allow for space and landscaping to be provided between above 7.5 metres height or part thereof
buildings including adequate area at ground level for (f) Rear boundary The front setback is therefore seen to align with the requirements of
landscaping with trees, shrubs, outdoor living and utilities; i. first and second storeys—6 metres PO9 as follows:
(f) be consistent with the predominant character of the ii. third storey and thereafter— 8 metres The setback maintains privacy for future residents through
surrounding area; and the provision of screening elements within the front
(g) protect the natural character and avoid adverse impacts on elevation. The setback of 9.9m to the wall provides a
ecologically important areas such as national parks, suitable setback to the street to ensure retained privacy for
waterways and wetlands. the existing dwellings located across Elanda Street.
Existing buildings within the street exhibit similar setbacks
to those proposed as part of this application. 61 Elanda
Street is identified with a consistent 6m setback for each
level. A setback of 9.9m is achieved to upper level walls,
providing additional separation from the front boundary
and providing a notable step in the building form. The
setbacks and design of the building is therefore seen to
align with the prevailing built form and character of the
street.
The setbacks allow for the provision of the front stair case
elements which form a design feature within the front
elevation. This element creates visual interest within front
elevation positively contributes to the visual aesthetics of
the street.
The setbacks of the upper level does not impact on existing
vegetation within the site.
Town Planning Report - 65-67 Elanda Street, Sunshine Beach 35