EFFECTIVELY.
REPAIRS AND/OR MAINTENANCE SHALL BE UNDERTAKEN
76
75
REGULARLY AND AS REQUIRED, PARTICULARLY FOLLOWING
into lot 17
4.
4.
STORM EVENTS.
11. ACCEPTABLE RECEPTORS SHALL BE USED FOR CONCRETE
35
2.
27
window
2. AND MORTAR SLURRIES, PAINTS, ACID WASHINGS, LIGHT-
WEIGHT WASTE MATERIALS AND LITTER. WASTE FROM
THESE RECEPTORS SHALL BE DISPOSED OF IN
ACCORDANCE WITH REGULATORY AUTHORITY
REQUIREMENTS. PAY ALL FEES AND PROVIDE EVIDENCE OF
30
PROPOSED TREES TO BE SAFE DISPOSAL.
2.
RETAINED TYPICALLY SHOWN
32
21
21
2.
2.
2.
PARKING AND HOURS OF OPERATION
15
40
40
• CONTRACTORS MUST PARK INSIDE THE BOUNDARIES OF
PRELIMINARY
9.
9.
LOT 17. NO CAR SHALL BLOCK OR INTERFERE WITH THE
ACCESS PATH OF ANY NEIGHBOURING DWELLING.
NOT FOR CONSTRUCTION • ALL HOURS OF WORK ARE TO BE IN ACCORDANCE WITH
THOSE PRESCRIBED IN COUNCILS CONDITIONS..
Client Address Drawn Scale
NOTE: GENERAL NOTES: NOTE:
All work to be carried out in accordance with the Building Code of Australia, all Local and Do not scale off the drawings unless otherwise stated and use figured DM 1 : 50@A1
All existing & overall dimensions are nominal & subject to verification on
site. where any discrepancy occurs between new work & existing State Government Ordinances, relevant Australian Standards, Local Electricity and Water dimensions in preference. All dimensions are to be checked and verified on site WADLAND 'THE HASTINGS' - LOT 17, 30
WADLAND - DA ISSUE
Check Issue
dimensions - existing dimensions/work should take preference where Authorities Regulations and all other relevant Authorities concerned. before the commencement of any work, all dimensions and levels are subject to
necessary - otherwise notify Innovate Architects Pty Ltd. All structural work and site drainage to be subject to Engineer's details or certification final survey and set-out. No responsibility will be accepted by this firm for any
variations in design, builder's method of construction or materials used,
HASTINGS ST, NOOSA HEADS GJ
Selected termite protection to be used on site in accordance with local
council's requirements, B.C.A and all relevant Australian Standards.
where required by Council. This shall include r.c. slabs and footings, r.c. and steel beams
and columns, wind bracing to AS 1170 and AS4055, anchor rods or bolts, tie downs, fixings
etc., driveway slabs and drainage to Council's satisfaction.
deviation from specification without permission or accepted work practices
resulting in inferior construction. Locate and protect all services prior to
Project
Suite 9b, 32 Frederick Street
Oatley NSW 2223
T
F
02 9585 1855
02 9585 1844
M E M B E R Date
MAY 2020
A
All timbers to be in accordance with SAA Timber Structure Code AS1720 and SAA Timber construction. Drawing Title E [email protected]
PO BOX 214 Oatley NSW
S Smoke detectors to comply with requirements of specification e1.7 (NSW) Framing Code AS 1684. All work to be carried out in a professional and workmanship like W www.innovate.com.au
Job Number Sheet
fire and smoke alarms shall comply with AS 3786 and be connected to the
main power supply.
manner according to the plans and specification. COPYRIGHT CLAUSE: ALTERATIONS AND CONSTRUCTION REGIST ERED ARCHIT ECT S
This drawing and design is the property of Innovate Architects Pty Ltd and
should not be reproduced either in part or whole without the written consent of ADDITIONS TO EXISTING MANAGEMENT PLAN Nominated Architect
Cameron Jones
7143 04
this firm. 0 0.5 1 1.5 2 2.5
A DEVELOPMENT APPLICATION
ISSUE AMENDMENT
MAY 2020
DATE
DM
INT.
DWELLING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment A - Proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.