Original source · versioned page text
MCU19/0017.07 - Development Application For Other Change To Development Approval For Commercial Business Type 1 Office, Commercial Business Type 2 Medical To Health Care Service, Hospital And Hospital (Infusion Centre) And Ral 19/0004.07 Reconfiguring Lot At 36-40 Hofmann Drive, Noosaville · Attachment 3 - MCU19 0017.07 - Proposal Plans
Plans and drawings: the text below has words only, no drawings.
PYLON SIGNAGE TO COMPLY WITH NOOSA COUNCIL ADVERTISING DEVICES CODE
GROUND FLOOR PLAN
BOOSTER ASSEMBLY CABINET
& FIRE HYDRANT BOOSTER TH
TPA
FO O
RI VE TRANSFORMER
AN ND TRANSFORMER
HOFM
1x NEW PARKING SPACE
RAISED KERB
5400
5 6 7 8 9 10 11 12 MIN. EXISTING CAR PARKING
ADJUSTED BOUNDARY 2500
2885
F 4
AREA 85m² DROP OF
3 2600 2600 2600 2600 2600 2600 2600 2600
2388
PROPOSED LANDSCAPE TO BE IN 3800
ACCORDANCE WITH OPERATIONAL WORKS INVERT
G EASEMENT 7500
APPROVAL EXISTIN
LINE OF
PYLON SIGN 0 750
SITE ACCESS
REFUSE VEHICLE SWEEP PATH AS
TH
FOOTPA 0 CONFIRMED BY TRAFFIC ENGINEER
LANDSCAPED 660 BOLL
NE
STORM WATER
AREA
PROTECTION
ZO
1:150 SLOPE
DOWN FOR
IN G 1
AD
F / LO
0 OF
EASEMENT 660 OP
BICYCLE RACKS
LINE O F N EW DR
O F O VER
2 LINE OF RO
225
0
LINE OF ROOF OVER AMBULANCE
DROP-OFF
LINE OF ROOF OVER
PUMP ROOM
STAIR
WASTE LOADING BAY
MSB
WALKWAY ABOVE
SHOWN DASHED TANK
SUITE 2
6625 PLAZA PLANT
BOLL BOLL
COMMS SCREENS
STONE TILE CLAD FINISH TO FIRE DOOR
BIO RETENSION WALLS SUITE 1 - HOSPITAL 2600 2600 350 2600 2600 2600
PLANTER
(INFUSION CENTRE) END OF TRIP
84 85 86 87 88
BIO
RETENSION METER CUPBOARD ROLLER DOOR
STAIR
FIRE RATED PARTY WALL
SUITE 6 SUITE 7
WALKWAY
ABOVE
LOBBY SHOWN
CORRIDOR
DASHED
STAIR
EXISTING
1940
LIFT
83 82 81 80 BUILDING
600 2600 350 2600 2600 2600
SCREEN WITH DOOR SUITE 9 SUITE 8
PLAZA 600 2600 350 2600 2600 2600
FIRE EXIT STAIR
CANVAS OR 76 77 78 79
GLASS ROOF
BICYCLE PARKING
OVER
PLANTER
CHAINWIRE FENCE
ALONG TOP OF EXISTING
BLOCKWORK WALL -
SHOWN DASHED
VOID ABOVE
STAIR
BUNKER BUNKER
SCREEN WITH DOOR
2300 2300 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600
FIRE EXIT STAIR
STAFF STAFF STAFF STAFF
5400
TURNING 25 24 23 22 21 20 19 18 17 16 15 14 13
ONLY ONLY ONLY ONLY
SMALL
SMALL
5400
BAY
45 43 41 39
2500
M7 M8
2500
12001200 2300 2300 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2400 2400 2400 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 M1 M2 M3 M4 M5 M6
SMALL
SMALL
STAFF STAFF STAFF STAFF MOTORCYCLE
5400
5400
5400
54 52 51 50 49 48 47 46 ONLY ONLY ONLY ONLY 37 36 35 34 33 32 31 30 29 27 26 PARKING SPACES
56 55 53 44 42 40 38 28
1200 1200 1200
TURNING BOLL 1200 1200 1200
BAY
6250
6250
61
5400
57 58 59 60 62 63 64 65 66 67 68 69 70 71 72 73 74 75
PLANT RAMP UP TO LEVEL 1
2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 GRADIENT 1: 72
1980
LANDSCAPING
FIRE RATED PARTY WALL
FENCE ALONG BOUNDARY LINE EDGE OF CARPARK
SETBACK FROM BOUNDARY INDUSTRIAL ZONE
20 m
0 2 4 6 10
NOOSA HEALTH PRECINCT © Copyright Thomson Adsett Pty Ltd.
ABN 76 105 314 654
GROUND FLOOR PLAN
Dimensions take precedence over Telephone +61 7 3840 9999
HOFMANN DRIVE, NOOSAVILLE QLD scaling. Do not measure off drawings [email protected]
as print sizes may vary Level 9, 470 St Pauls Terrace 1 : 200 @ A1 2025-08-08
Fortitude Valley
Qld 4006 Australia
TRIDENT GROUP HOLDINGS PTY LTD thomsonadsett.com TA # 22.0290.17 DA-21.20A rev. 63