Council archive · source document
Appendix A - Facilities Building Minor Change to Architectural Plans · 132005.1133.15
Plans and drawings: the text below has words only, no drawings.
Very large file (32.7 MB): may take a few minutes to open.
Original PDF page 19, section 1. The text section number identifies this passage in the reader.
E02
4795
210 90 3255 1150 90
LINE OF EXISTING ROOF OVER
50
90
40
SHELVING
1300
1210
NEW WINDOW
STUD FRAME WALL
ON TOP BRICK SILL
CIRCULATION
ZONE
3470
40
1070
RELOCATED
EXISTING FRIDGES E03
NEW AUTOMATIC
1500
SLIDING DOOR 40
1500
E01
1010
1100
300
SHELVING
90
50
LINE OF EXISTING ROOF OVER
NEW FULL HEIGHT STUD FRAME WALL
210 90 4405 90
6 PERSPECTIVE VIEW 7 PERSPECTIVE VIEW 4795
CONVENIENCE STORE CONVERSION NTS CONVENIENCE STORE CONVERSION NTS
EO4
1 PART PLAN
SELECTED AUTOMATIC FACE SLIDING DOOR CONVENIENCE STORE CONVERSION SCALE 1:50
9mm FIBRE CEMENT EXPRESSED
JOINT SYSTEM WITH PAINT FINISH
90mm STUD FRAMED WALL
WITH BULK INSULATION
LINEA BOX CORNER TRIM
OR EQUIVALENT TO MATCH
LINEA WEATHERBOARD
TO MATCH EXISTING
FOR INFORMATION ONLY
VAPOUR BARRIER / SARKING
EXISTING ROOF STRUCTURE TO
BE PROTECTED & REMAIN
EXISTING ROOF STRUCTURE TO
BE PROTECTED & REMAIN
EXISTING ROOF STRUCTURE TO EXISTING ROOF FLASHINGS,
BE PROTECTED & REMAIN GUTTERS & DOWNPIPES TO
REMAIN
FLASH & SEAL AS REQUIRED TO FLASH & SEAL AS REQUIRED TO
ENSURE WEATHER TIGHT SEAL FLASH & SEAL AS REQUIRED TO ENSURE WEATHER TIGHT SEAL FLASH & SEAL AS REQUIRED TO
ENSURE WEATHER TIGHT SEAL ENSURE WEATHER TIGHT SEAL
9mm FC TYPE EXPRESSED JOINT
CLADDING SYSTEM NEW FULL HEIGHT STUD
EXISTING BRICK COLUMN & FRAMED WALL WITH
SILL HEIGHT BRICK TO WEATHERBOARD CLADDING
REMAIN WHERE INDICATED NEW FULL HEIGHT STUD
FRAMED WALL WITH
WEATHERBOARD CLADDING
NEW FACE SLIDING AUTOMATIC
ENTRY DOOR
NEW STUD WALL WITH EXISTING BRICK COLUMN &
WEATHERBOARD CLADDING SILL HEIGHT BRICK TO
REMAIN WHERE INDICATED
EXISTING FFL EXISTING FFL EXISTING FFL EXISTING FFL
2 ELEVATION 3 ELEVATION 4 ELEVATION 5 ELEVATION
CONVENIENCE STORE CONVERSION SCALE 1:50 CONVENIENCE STORE CONVERSION SCALE 1:50 CONVENIENCE STORE CONVERSION SCALE 1:50 CONVENIENCE STORE CONVERSION SCALE 1:50
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
notes : issue amendment log by date issue amendment log by date project: north
01 PRELMINARY BA ISSUE TJP 15-07-21
date: APR 2021
1 The designs, drawings and specification are PARKRIDGE FACILITIES BUILDING
copyright and always remain the property of UPGRADES drawn:
Blackburne Jackson Design Pty Ltd.
A R C H IT E C T UR E | L A ND S C A P E | INT E R IO R | P R O J E C T M A N A G E M E N T checked:
2 Before commencing construction: client:
- Verify all dimensions and levels.
- Verify location and levels of all services on site. ALTUM CONSTRUCTIONS scale: 1:50, 1:5
- Verify that floor levels and finished levels will 37 Aerodrome Rd Maroochydore Qld title:
enable connection to services. P.O. Box 154 Cotton Tree Qld 4558 phone 07 5443 3200 project/drawing no. sheet: A1
email [email protected] fax 07 5443 4030 FACILITIES BUILDING ADDITIONS -
3 Do not scale this drawing.
When in doubt refer to Architects. CONVENIENCE STORE 5737_A12-02_01
5737-22-PARKRIDGE FACILITIES UPGRADES.pln printed: Friday, 16 July 2021 11:31 am
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Facilities Building Minor Change to Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 32.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.