Original source · versioned page text
RFI - RECOR Preliminary Stormwater Management Report - 20220078
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
SITE DETAILS
2.1. Existing Site Description & Drainage
The existing site, known in real property terms as Lot 40 RP 139776, is located at 6 Wyandra Street having frontage
to both Wyandra Street and Safari Street. The existing site contains a residential dwelling with a site area of 598m².
2.2. Existing Drainage Patterns
The subject land falls typically south-west towards Wyandra Street at grades varying across the site. The natural
surface falls at between 20% to 30% along the site boundaries, however the centre of the site containing the existing
dwelling is flatter at approximately 10%.
The run-off from the site typically drains as overland surface flows towards the south-west where it is captured by the
stormwater infrastructure within the road reserve. Two existing kerb inlet pits within the road reserve are likely to
capture all run-off from the existing site.
Roof run-off is conveyed by downpipes below ground, and it is considered that a kerb adapter outlet observed in
the Safari Street frontage kerb is the discharge point for these pipes.
Due to the sloping nature of the site, run-off from the upstream adjacent properties to the north and east is expected
to drain across the subject site.
Figure 2.1 - Site Locality Plan (Noosa Council Intramaps, 2022)
Project number 20220078
File RECOR Preliminary Stormwater Management Report - 20220078, 2022-11-11 Page 6 of 16
Revision 2
P +61 7 5211 1003 A 75 Noosa Drive, Noosa Heads Qld 4566 E [email protected] recorconsulting.com