                                                                                                                                                         refer to Level 3 Floor Plan for
                                                                                                                                                         details of roof works to this roof




                                                                                                                                                                                                                                          ex.flue to removed
                                                                                                                                                ex.gutter to remain




                                                                                                                                             20°
                                                                                                                                             fall
                                                                                                                                                                             exist. steel outriggers to this                      exist. custom orb roof
                                                                                                                                                                             roof to remain                                       sheeting to remain -
                                                                                                                                                                                                                                  exist. solar pool heating
                                                                                                                       exist.
                                                                                                                      10° fall




                                                                                                                                                                                                                                  system to remain




                                                                                                                                                                                                                   20° fall
                                                                                                                                                                                                                                                                                                                    exist. steel outriggers to this




                                                                                                                                                                                                                                                                                       20° fall
                                                                                                                                                                                                                   exist.




                                                                                                                                                                                                                                                                                       exist.
                                                                                                                                                                                                                                                                                                                    roof to remain

                                                                                                                                                                             exist. wall capping under - to be
                                                                                                             exist. roof sheeting                                            repaired / replaced if needed - cos
                                                                                                             to remain




                                                                                                                                                                                                                                                                                                                  exist. roof sheeting / steel outriggers to




                                                                                                                                                                                                                                                                                                           20°
                                                                                                                                                                                                                                                                                                                  remain to lower section




                                                                                                                                                                                                                                                                                                           fall
                                                                                                                                                                                                                       exist. curved roof sheeting to remain
                                                                                                                      20°
                                                                                                                      fall




                                                                                                                                                                                                                                                                                                           20°
                                                                                                                                                                                                                                                                                                           fall
                                          exist. box gutter - to be rectified due to                         exist. roof sheeting                                       ex.gutter to remain
                                          exist. water damage / make good                                    to remain                                                                                                        exist. roofing, including structural
                                                                                                                                                                                                                              purlins to higher section roof to be         exist. box gutter - to be              exist. roofing to higher section roof to
                                                                                                                                                                                                                              removed / replaced                           rectified due to exist. water          be removed / replaced
                                                                                                                                                                                                                                                                           damage / make good




                                                                                              01                 EXISTING & DEMOLITION ROOF PLAN                                                                                   walls / fixtures to be demolished - make good where req'd
                                                                                              -                  1:100@A3 / 1:50@A1                                                                                                typ. 90mm internal stud wall - u.n.o.
                                                                                                                  0              1.0   2.0            5.0m                                                                         existing wall/s to remain (make good as req'd)

                                                                                                                                                                                                                                                                                                                   01           ENGINEERING & CERTIFICATION ISSUE        19.05.2020
                                                                                                                                                                                                                                                                                                                   Issue         Amendment                               Date
                                                                                       bsa lic.no.1071865




The design & drawings shown on these                                                                        PROJECT                                                                                                                        DRAWING TITLE                                                           SCALE                                       DWG No.   ISSUE
                                                                                                                                                                                                                                                                                                                     1:100@A3 / 1:50@A1
plans are copyrighted and remain the                                                                         Alterations & Extensions for Goetz Maeuser & Louise Biddell                                                                   Existing & Demolition ROOF PLAN
property of 'georgina price design'. No
unauthorised copies shall be made.                                                                           8/27 Ross Crescent, Sunshine Beach Q                                                                                                                                                                  DATE
                                                                                                                                                                                                                                                                                                                        May 2020
                                                                                                                                                                                                                                                                                                                                                                A.05      01

Used in these records

About this file

File size
2.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

proposal plans.pdf · 2.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.