Original source · versioned page text
210723 23 - 2 Pandorea Court, Noosaville Town Planning Report
driveway is required.
Streetscape and effect on traffic network
PO13 AO13.1 AO13.1-AO13.2 Not Applicable
The visual impact of driveways on Areas adjoining driveways Driveways and vehicular access
the streetscape and surrounding disturbed as a result of the will not be altered.
area is minimised and significant driveway construction are grassed
adverse impacts on the traffic or planted to minimise visual impact
network are avoided. and stabilise the soil.
AO13.2
Vehicular access avoids
disturbance to the tree protection
zone of trees on public land.
Driveway Location
PO14 AO14.1 AO14.1-AO14.4 Not Applicable
Driveways and crossovers are Only one driveway and crossover is The existing driveway will not be
located so they do not impede the provided. altered.
safe and efficient use of the road AO14.2
network. Where the premises has frontage to
more than one formed and sealed
road and the roads have differing
orders in the Road Hierarchy, the
driveway and cross-over is
provided on the frontage with the
lower order.
AO14.3
For corner lots, driveways and
crossovers are located in
accordance with Council's standard
drawings.
AO14.4
If in the Rural zone or Rural
Residential zone, the driveway and
cross-over is located to provide
minimum safe sight distances in
accordance with Austroads.
Editor's Note - An operational
works application is required for a
second driveway.
Bushfire Hazard Management
PO15 AO15 AO15 Not Applicable
Where located in a Bushfire Within a bushfire hazard area The subject site is located within
Hazard Area as shown on where there is no reticulated water the urban boundary and contains
the Bushfire Hazard Overlay supply, the premises has: reticulated water supply.
Map in Schedule 2 and not in a
water service area, an adequate, 1. an accessible dam,
reliable, safely located and freely swimming pool or water
accessible water supply is tank available for
provided for fire fighting purposes, firefighting purposes with
which is in addition to day to day an onsite water volume of
water supply. not less than 5,000 litres;
and
2. a water supply outlet pipe
50 millimetres in diameter
and fitted with a standard
fire brigade fitting
28
Building Work (Development Permit)
Extensions to a Dwelling House – 23/2 Pandorea Court, Noosaville
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.