Original source · versioned page text
Geotechnical Report
Attached to the e-mail MCU16/0081 Geotechnical report, Landscape Plan, SMP, Traffic report - Email 3 of 3.
Quality of Materials Report
Client: Core Consulants Pty Ltd Report Number: G16003 - 59/1
Client Address: 55 Kingsford Smith Parade Maroochydore QLD 4558
Job Number: G16003 Report Date: 4/04/2016
Project: Laboratory Testing Samples Supplied Order Number: -
Location Job No:J000206 , Aged Care Facility,Walter Hay Drive Page 1 of 1
Lab No: 105021 Sample Location
Date Sampled: 22/03/2016 Test Pit 2
Date Tested: 31/03/2016 Depth 0.9m
Sampled By: Client Supplied 29/03/16
Sample Method: N/A
Material Source: Site Spec Description: -
For Use As: - Lot Number: -
Remarks: - Spec Number: -
A.S. Sieve Sizes Specification Percent Specification
Minimum Passing Maximum
Test Method: AS1289.3.6.1
75.00 mm
53.00 mm
37.50 mm
26.50 mm
19.00 mm
13.2 mm
9.50 mm
6.7 mm
4.75 mm
2.36 mm
1.18 mm
0.600 mm
0.425 mm
0.300 mm
0.150 mm
0.075 mm 99
Atterberg Tests Test Method Specification Result Specification
Minimum Maximum
Liquid Limit (%) AS1289.3.1.2 78
Plastic Limit (%) AS1289.3.2.1 23
Plasticity Index AS1289.3.3.1 55
Linear Shrinkage (%) AS1289.3.4.1 18.5
Approved Signatory Form Number
Accredited for compliance with ISO/IEC 17025
REP AQUAL-1-7
Mel Burnett