Attachment 3 EZGREY User Manual Application for a Development Permit – Material Change of Use to establish Short- Term Accommodation – 2 cabins. 637 Black Mountain Rd, Black Mountain 4563 QLD Lot 2 on RP167390 Joe and Heide Veraa (nee De Wald) 1st August 2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (RFI - Att 3 - EZGREY Manual.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 16 pages
Page 2
‘ AWWS EZGREY System Greywater Diverter OIM Manual Operation - Installation - Maintenance Grey Water Reuse System [_] EZGREY (GF-EZ) —— “Moving NACo www.greyflow.net.au
Page 3
Contents:
OPERATION:
Selection & Operation Page 3
Requirements Page 4
INSTALLATION:
Parts list & Components Page 5
Important Do's and Don'ts Page 6
Operating Modes Page 7
Step One: EZGREY tank positioning Page 8
Step Two: Plumbing and power connection Page 9
Step Three: Installing the irrigation system Page 10-11
MAINTENANCE Page 12
TERMS OF WARRANTY Page 13
DISCLAIMER Page 14
Eee
a COLUCU WAN www.greyflow.net.au
Page 4
Selection and Operation Congratulations, You've taken an important step towards envi- ronmentally friendly living with your purchase of the EZGREY greywater diversion and reuse system. The EZGREYSystem was developed for above ground / partially buried installations and can be retrofitted into almost any house. In some parts of the world the EZGREY is known as the auto- matic bucketting system, and has been used extensively in drought striken areas to keep garden green, save water, and beat water restrictions. Please note: Due to its high fat content, water from kitchen is harmful to soils, and is not considered suitable for reuse in gardens with the EZGREY system. Manual diversion of the Grey Water to sewer is achieved through the 50mm 3-way valve and manifold supplied with the unit. a COLUCU WAN www.greyflow.net.au
Page 5
Requirements - The water discharge should be kept below mulch or soil (check for local state, municipal & council laws and regulations) - 220Volts power supply should be available - The EZGREY can be turned off during wet conditions and any sign of accumulation or run-off - Allminimum irrigation areas and set back distances must be in accordance to local regulations - Table 1.0 provides an estimated average volume of greywater that is generated in various parts of the house. Refer to your greywater state guidelines to evaluate your minimum irrigation area requirements. Table 1.0 eam eC LCC et AComt stew oath ted People LS SST Laundry Only Whole of House Laundry House Laundry House Sandy 122 | 30 24 60 2, 3 120 300 Loamy 18 45 36 90 Clay 24 60 48 120 Sandy 16 40 32 80 3 4 160 400 Loamy 24 60 48 120 Clay Ba 80 64 160 Sandy 20 50 40 100 4 5 200 500 Loamy 30 7 60 150 Clay 40 100 80 200 Sandy 24 60 48 120 5 6 240 600 Loamy 36 90 72 180 Clay 48 120 96 240 Sandy 28 70 56 140 6 i) 280 700 Loamy 42 105 84 210 Clay 56 140 112 280 Sandy 82 80 64 180 7 8 320 800 Loamy 48 120 96 240 Clay 64 160 128 320
Page 6
Parts List & Components The G-Flow Complete System is supplied with: 1x Corflute Greywater cree warning sign a ___ [tis Proverry 1x EZGREY lid cover ——————__ wat 1x Graded lint fi Iters TT (+1 extra set for easy swap over) 1x50mm overflow ee a manifold a el Ds 1x Inlet manifold 1x 50mm 3-way valve 1 x EZGREY tank 1x Submersiblepump = ~——————_ with vertical float switch
Page 7
Important Do’s and Don’ts Never operate the EZGREY system without the filter firmly positioned in place Quick connect camlock fitting Filter set See As www.greyflow.net.au
Page 8
Operating Modes
{— EZGREY in shut off mode \
The greywater
Greywater inlet ="
=a |
3-Way valve handle is in the
horizontal position, EZGREY
is in shut off mode and the
greywater overflows to sewer
XY
3-Way valve handle is in the
vertical position, Greywater is
forced through the filters into
the pumped out chambers
The greywater
overflows to sewer
3-Way valve handle is in the
vertical position and allows
water in the EZGREY.
The filters are blocked, water
overflows back to sewer via
the overflow opening
LEU ASCs www.greyflow.net.au
Page 9
Step One: EZGREY Tank Positioning Option 1: Above ground option Option 2: Below ground option (in paving or garden bed area)
Page 10
Step Two: Plumbing and power connection Outdoor GPO EZGREY Size: Height 0.6m Width 0.4m Depth 0.4m Option 1: Option 2: (Additional piping and fittings are not included) Greywater inlet Greywater inlet a Greywater overflow See As www.greyflow.net.au
Page 11
Step Three: Installing the Irrigation System Option 1: Single Station EZGREY with GF Drip-Tube Kit i ue Ha —_ Minimum pipe size 1” 1.25mm or larger feeder pipe 2. Coil of GF Drip-Tube around trees 3, Elbow take-off adaptor 4. 16mm GF Drip-Tube (no more than 7m length 5.25mm flush manifold 6. Manual flush valve GREY WATER IN USE ON THIS PROPERTY Greywater Warning Sign to be visible at all times *Use of a non Grey Flow dripline will void the system warranty
Page 12
Step Three: Installing the Irrigation System Option 2: Multi station distribution using GF Rotor Greywater Warning Sign . to be visible at all times Use GF Rotor flow based indexer GREY WATER E f to split the system into more IN USE ON (x) OX) than one station. Up to 6 stations. THIS PROPERTY fe f LN Q ® 2 or more stations x) (x) : can be joined to form é a single station Make a hole with (x) punch tool & insert , drip tube takeoff Minimum of 4 and 2 r oO maximum of 8 trees «) per station (one emitter , ; per tree) 1" Low density poly . «) When using driplines make supply pipe. (Not supplied ‘ sure to adhere to the max «) ' with the system. To be run length of 7 yards per purchased separately) take-offs ® ® ® ® we 3 8
Page 13
Maintenance To retain the original reliability and performance of the EZGREY System the following maintenance procedure should be followed. Please ensure that you wash your hands thoroughly after contact with Greywater or handling any part of the EZGREY System. The following maintenance steps should be carried every 3 months and not less than once every 6 months: - Open top cover of the EZGREY tank - Remove primary sponge filters and wash thoroughly in a bucket, with a garden hose or in any basin not connected to the dedicated Greywater line - Re-insert the filter in its original position, close the lid of the tank and the EZGREY System is ready to operate again. The following maintenance steps should be carried out once a ear: » Open top cover of the EZGREY tank - Remove the primary sponge filters and wash thoroughly in a bucket, with a garden hose or in any basin not connected to the dedicated Grey water line. - Wash thoroughly the tank with a garden hose and drain the tank using the pump to discharge to a sewer outlet (the irrigation system should be disconnected during this process) - Disconnect the EZGREY pump and connect the supplied going away backup quick connector. - Flush the Grey Flow emitters with fresh water for about five minutes. - Re-insert the filter, reconnect the pump, close the lid of the EZGREY tank and the EZGREY system is ready to operate again. - Top up mulch over the Grey Flow emitters to a minimum depth of 100mm.
Page 14
Limited Consumer Warranty ADVANCE WASTE WATER SYSTEMS Two Year Limited Warranty Advance Waste Water Systems (AWWS) warrants this product against material defects in mate- rials and workmanship for a period of TWO YEAR from the date of the original retail purchase (warranty period). Warranty work will be done in accordance with the following terms and con- ditions. This warranty only benefits the original purchaser. THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. THIS WARRANTY DOES NOT COVER ANY OF THE FOLLOWING: 1. Expendable items that can wear out from normal use, including but not limited to, filters, or similar perishable parts. 2. Damage to or failure of this system if it is not installed, operated, or maintained according to all instructions supplied with the system. 3. Damage to or failure of this system resulting from accident, abuse, misuse, or use for other than its intended purpose, Act of God. 4. Damage to or failure of parts or system resulting incomplete or improper instal- lation or from unauthorized modifications made to this system. 5. Ifyou purchase the system from an unauthorized retailer or dealer. 6. Damage caused by power surges, electrical storm damage, incorrect power supply, or insect or vermin infestation 7. Damage to or failure of parts if this system is serviced or rapaired by anyone other than an Authorized Service Center. 8. This warranty extends only to you, the original purchaser. It is not transferable to anyone who subsequently purchased this product from you. 9. Use for more than a single family or use in a commercial establishment or for commercial non-household purposes. 10. Parts and systems not supplied by AWWS are not covered by this warranty Any item which has been repaired or replace under this warranty shall be covered for the remainder of this original warranty as extended by the number of days that the product has been out of your hands for repair.
Page 15
Disclaimer Disclaimer of implied warranties; Limitation of remedies 1. All implied warranties, including implied warranties of merchant ability and fitness for a particular purpose, are limited in duration to one year from the date you purchased the product. 2. Neither AWWS nor its affiliates are responsible or liable for any loss, inconvenience or damage, whether special, exemplary, direct, incidental, consequential or otherwise, and whether known or should have been known to AWWS including damage to or replacement of other equipment and property and personal injury resulting from any breach of warranty, the inability to use the product or under any legal theory in contract or tort. There warranties and remedies are the sole and exclusive warranties and remedies given by AWWS in con- nection with the sale and use of the product. No other warranties, oral or written, express or implied are given. 3. Inany event, AWWS's entire liability shall be limited to the actual purchase price you paid to the retail seller of the defective product. This limitation applies whether damages are sought or a claim made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim or any other claim. This limitation cannot be waived or amended by any person. This limitation of liability is effective even is AWWS or any authorized repre sentative of AWWS has been advised by you of the possibility of such damages. This limitation of liability, however, shall not apply to claims of personal injury. 4.No AWWS dealer, agent or employee is authorized to make any modification, extension, change or amend- ment to this warranty. YOUR RESPONSIBILITY The above limited warranties are subject to the following conditions: You must provide your original bill of sale, invoice or other proof of purchase of the system showing that you are the original purchaser, that the purchase was made within two years of the date of your claim and that you purchased it from an authorized dealer or retailer. No warranty ee will be done without this information. Keep a copy of your receipt or invoice for your own records. These limited warranties are effective only if this system is purchased and used in AU region Labor and service charges for warranty repair, installation, set up, and adjustment of customer control are not covered by these limited warranties. Should you encounter a defect in the system, www.greyflow.net.au to find the closest authorized service center. Contact the center and itwill arrange for an inspection and corrective action, if needed and if covered by this warranty. Should the center determine that the system is not covered by this warranty; any corrective work will be per- formed at your request and at your expense. If the center makes a second and/or subsequent visit and deter- mines that there is no problem or that the system is not covered, the service call will be charged to you. When making a warranty clain, please be prepared to provice a description of the system, your name, address, Ne eae Sevier number, a description of the problem, the date you purchase the system and the identity of the seller. “moving Nee yA www.greyflow.net.au
Page 16
Advance Waste Water Systems Pty Ltd P.O. Box 561, Floreat, WA6014 Mob: 04-0545-9533 Tel: 08-9467-5990 r( AWWS Fax: 08-9309-2304 Advanced Waste Water Systems Email: [email protected] www.greyflow.net.au www.greyflow.net.au ar U Renae
Page 17
a G STRATEGIC STRATEGIC SOLUTIONS, CREATIVE THINKING rgstrategic.com.au