Original source · versioned page text
Attachment B - Cooroy and Lake Macdonald Locality Code
Attachment B Cooroy & Lake Macdonald Locality Code Development Permit for Material Change of Use Transport Type 2 Carpark situated at 4 - 8 and 16 Lower Mill Road, Cooroy and described as Lot 5 on SP213104 and Lot 7 on SP173771 Column 1 Column 2 Column 3 Specific Outcomes Probable Solutions (if code assessable) Compliance O12 For Multiple housing Type 3 or 4, Not applicable Visitor accommodation Type 4, or the accommodation unit component of an Entertainment and dining business Type 3—maximum gross floor area is equivalent to the maximum allowable population in persons multiplied by 40m2 . O13 For the Business Centre Zone plot Not applicable ratio does not exceed— a) 0.8:1 for site areas up to and including 2,000m2 ; and b) 0.3:1 for the balance of a site over 2,000m2. O14 Buildings and other works are S14.1 For new buildings or structures or Not applicable – no habitable rooms or designed and sited to— additions of more than 50m2 gross floor area structures proposed. a) provide flood free access to premises to an existing building or structure, floor levels and flood free habitable areas; for habitable rooms are— b) allow only minor, short term and a) for areas where minimum floor levels are infrequent flooding of non-habitable areas; available—not less than the specified level; c) ensure carparking areas can be b) for areas where flood modelling is adequately drained; available—a minimum of 300mm above the d) ensure drainage does not adversely modelled flood level; and impact upon other premises; and c) for areas where flood modelling is not e) ensure filling or excavation does not available, a minimum of 300mm above the adversely impact upon other premises highest known flood level; AND by— i. causing ponding of water on the site or S14.2 Where Council infrastructure is Proposal able to comply. Stormwater nearby land; available— Treatment and Water Quality Management ii. increasing flooding, which adversely a) any drainage (including buildings and Plan indicated that the upgrade of the existing affects the safety or use of any land yards) flows to that infrastructure; and bio basins on site would achieve compliance. upstream and downstream; and b) the infrastructure has the capacity to accept iii. adversely affecting the flow of water in any additional loading; AND any overland flow path. S14.3 Car parking and maneuvering areas are Complies constructed at a level that permits the parking area to drain from the site by gravity means, without the need for mechanical pumping; or S14.4 Basements for residential uses have Not applicable flood immunity above the 1%AEP defined flood event where alternative means to mechanical pumping are used to achieve such immunity; or S14.5 Basements for non-residential uses Not applicable have flood immunity above the 1%AEP defined flood event that may be achieved by means of mechanical pumping where the mechanical feature is installed with adequate holding tanks a Sloping sites Not applicable O15 Roof form O16 Roof forms— S16.1 With the exception of industrial Not applicable a) contribute positively to the local skyline; buildings the main roof of the building has a b) complement the low rise character of roof pitch no less than 12 degrees and has the locality; minimum 600mm eaves to at least 75% of the c) use simple traditional roof designs, such perimeter of the building; AND as hipped, gabled or skillion; and Not applicable d) do not create opportunities for residents to overlook the private open space areas S16.2 Building and structures do not include of neighbouring properties. rooftop terraces. Page 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Attachment B - Cooroy and Lake Macdonald Locality Code.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.