Architecturals REV D

of 15

Page text shows just the words. Original shows the document exactly as it was published.

      GENERAL NOTES:
       - DO NOT SCALE FROM THIS DRAWING -                   ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE
       WRITTEN DIMENSIONS TAKE PRECEDENCE                   ATTACK IN ACCORDANCE WITH AS 3660.1 AND A DURABLE
       OVER SCALE.                                          NOTICE SHALL BE PLACED IN THE METER BOX INDICATING
       - ANY DISCREPANCIES WHICH THE                        TYPE OF BARRIER AND REQUIRED PERIODICAL
       CONTRACTOR MAY FIND IN THIS DRAWING                  INSPECTIONS.
       MUST BE BROUGHT TO THE ATTENTION OF
       EVOKE ARCHITECTS PRIOR TO                            SAFETY GLAZING TO BE USED IN THE FOLLOWING CASES-
       COMMENCEMENT OF WORK. - VERIFY ALL                   i) ALL ROOMS WITHIN 500mm VERTICAL OF THE FLOOR
       DIMENSIONS PRIOR TO ORDERING OR SHOP                 ii) BATHROOMS- WITHIN 1500mm VERTICAL OF THE BATH
       FABRICATION.                                         BASE
       - SMOKE DETECTORS TO BE WIRED INTO                   iii) FULLY GLAZED DOORS
       ELECTRICITY MAINS AND TO COMPLY WITH                 iv) SHOWER SCREENS
       NCC, PART 3.7.5.                                     v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR
          SD                                                LEVEL
                                                            vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL
       - ALL GLAZING TO COMPLY WITH AS 1288-2006            VARY WITH MANUFACTURER, FLASHING ALL ROUND.
       GLASS IN BUILDINGS & AS 4055-2012 FOR
       WINDLOADING.                                         NOTE: GLAZING REQUIREMENTS MAY BE DIFFERENT FROM
       - ALL CONSTRUCTION TO BE IN ACCORDANCE               THAT STATED UNDER BUSHFIRE CATEGORY
       WITH THE RELEVANT AUSTRALIAN                         REQUIREMENTS REFER 'BAL RATING'
       STANDARDS, THE NATIONAL CONSTRUCTION
       CODE & LOCAL AUTHORITY REGULATIONS                   FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR
       - FOOTINGS HAVE BEEN DESIGNED IN                     EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS
       ACCORDANCE WITH ASSOCIATED SOIL TESTS                ARE TO BE LOCATED IN CLOSE PROXIMITY OF BOUNDARIES,
       AND/ OR ENGINEERS SPECIFICATIONS.                    A CHECK SURVEY BE CONDUCTED BY A LICENSED
       - DRAWINGS TO BE READ IN CONJUNCTION                 SURVEYOR.
       WITH ATTACHED ENGINEERS NOTES.
       - ARTICULATION JOINTS TO ENGINEERS                   ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
       DESIGN REPORT
       - LOH - WHERE INDICATED TO BE REMOVABLE              ALL WET AREAS TO COMPLY WITH NCC 3.8.1.2 AND AS 3740.
       DOORS WITH LIFT OFF HINGES IN                        SPLASH BACKS SHALL BE IMPERVIOUS FOR 150mm ABOVE
       ACCORDANCE WITH NCC 3.8.3                            SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE
       - REFER ENGINEER'S PLAN FOR EXPANSION                WALL.
       JOINT LOCATIONS
       - WATER PROOFING TO WET AREAS TO                     PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL
       COMPLY WITH NCC, PART 3.8.1                          AND HORIZONTAL AND WITHIN 300mm OF ARTICULATION
       - SMOKE ALARMS TO BE INTER-CONNECTED                 JOINTS. BRICK TIES TO BE STAINLESS STEEL.

       SUSTAINABILITY COMPLIANCE                            THERMAL INSULATION; INSULATION TO CEILING AND
                                                            REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY
       1. TRIPLE 'A' RATED SHOWER ROSES.                    RATING REFER SARKING REQUIREMENT UNDER BUSH FIRE
       2. DUAL FLUSH TOILETS (6 LITRE FULL FLUSH /          CATEGORY. BEDROOMS REQUIRE MINIMUM 10% LIGHT & 5%
       3 LITRE HALF FLUSH).                                 VENTILATION TO TOTAL FLOOR AREA.
       3. 500kpa WATER PRESSURE-LIMITING
       DEVICES.
       4. ENERGY EFFICIENT LIGHTING TO 80% OF               RELEVANT AUSTRALIAN STANDARDS
       DWELLING INTERNAL FLOOR SPACE.
                                                            - CONCRETE CONSTRUCTION TO COMPLY WITH
       TERMITE PROTECTION:                                  NATIONAL CONSTRUCTION CODE.
       TO AS3660-2017 "TERMSPEC" TERMITE
       MANAGEMENT SYSTEM TO ALL SLAB                        - TIMBER STRUCTURE STANDARD AS 1720.3- 2016
       PENETRATIONS AND PERIMETER OF SLAB.
       CONCRETE SLAB TO BE DESIGNED AND                     - TIMBER CONSTRUCTION AS1684 - 2010
       CONSTRUCTED IN ACCORDANCE WITH AS2870.               - MASONARY STRUCTURES AS4773-2010
       REFER ENGINEERS PLAN FOR EXPANSION JOINT             - CONCRETE STRUCTURES AS3600-2018
       LOCATIONS.                                           - CONCRETE ROOF TILES AS2049-2002
                                                            - RESIDENTIAL SLABS & FOOTINGS AS2870-2011
       SLAB:                                                - WINDOW & GLASS INSTALLATION AS2047 AND AS1288.                                                                     HOUSE RELOCATION TO:
       STEPDOWNS TO EXTERNAL SURFACES TO                    - BARRIERS FOR SUBTERRANEAN TERMITES TO
       COMPLY WITH THE NCC. CONCRETE SLABS,                 COMPLY WITH THE PROVISIONS OF PART 3.1.3 OF THE

                                                                                                                         1383 GREENRIDGE PINBARREN RD, PINBARREN
       PATHS & DRIVEWAYS NOT DESIGNED BY                    NCC AND WITH AS3660.1-2014
       ENGINEER ARE NOT PART OF THIS APPLICATION.           - WIND LOADS FOR HOUSING AS4055-2012
                                                            - STEEL STRUCTURES AS4100-2016
       PLUMBING:                                            - DAMP PROOF COURSE & FLASHINGS AS/NZS2904
       PLUMBER / DRAINER TO VERIFY ALL DIMENSIONS           - PROTECTION OF MASONRY WALL TIES TO COMPLY
       PRIOR TO POSITIONING UNDERSLAB POINTS.               WITH THE PROVISIONS OF PART 3.3.3.2 OF THE NCC.
       MEASUREMENTS MAY VARY. FLOOR WASTE                   - PROTECTION OF LINTELS IN MASONRY TO COMPLY
       FIXTURES TO BE POSITIONED AT THE TIME OF             WITH THE PROVISIONS OF PART 3.3.3.4 OF THE NCC.
       CONSTRUCTION.

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION             REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY              A        CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED        B                CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED           C        PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT       D                1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                              SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                  REV                COVER SHEET
COMMENCEMENT OF WORK.
                                        887                 A - 01                    D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |
Log in to download the original file

Architecturals REV D.pdf · 2.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 14 pages

Page 2

                                                                                                                        COACHOUSE RD

                                                                                                                                          20100     90° 00' 00"




                                                                                                                                                                   180° 00' 00"
                                                                                                                            0° 00' 00"




                                                                                                                                                           64190
                                                                                                                            100500




                                                                                                                                                                   100500
                                                                                                                                                                                              EXISTING SHED




                                                                                                              LOT 403                             LOT 402                         LOT 401
                                                                                                              P4111                               P4111                           P4111
                                                                                                                                                  2020m²




                                                                                                                                         6515                      2100

                                                                                   FOUR TREES
                                                                                   REQUIRING REMOVAL
                                                                                   FOR HOUSE DELIVERY,
                                                                                   ALL OTHER TREES TO
                                                                                   REMAIN
                                                                                                                                                                                            PROPOSED
                                                                                                                                                                                            DWELLING
                                                                                                                                                                                                                 ENTIRE SITE COVERED BY FIRE HAZARD
                                                                                                                                                                                                                 BUSHFIRE PRONE VEGETATION



                                                                                                                                                   17100
                                                                                                                                                                                                                 OVERLAY




                       LOCATION PLAN                                                                                                     20100    270° 00' 00"                                                   ENTIRE SITE COVERED BY

          1              1 : 500 @A3
                                                                                                                                                                                                                 BIODIVERSITY ENVIRONMENT
                                                                                                                                                                                                                 ENHANCEMENT AREA




                                                                                             GREENRIDGE PINBARREN RD                                GREENRIDGE PINBARREN RD


ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.                                                      NORTH
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                LOCATION PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 02                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 3

                                                                   88.
                                                                      5




                                                                           89.
                                                                              0




                                                                                                                               6865                                                              2450

                                                                                                                               WALL                                                             WALL
                                                                                                                                                                                                                               PROPOSED
                                                                                                                                                                                                                               DWELLING
                                                                                                                               6515                                                                   2100

                                                                                                                               EAVE                                                               EAVE




                                                                                     89.5
                                                               FOUR TREES
                                                               REQUIRING REMOVAL




                                                                                                                                                                                                        180° 00' 00"
                                                               FOR HOUSE DELIVERY,




                                                                                                                  0° 00' 00"
                                                               ALL OTHER TREES TO
                                                               REMAIN




                                                                                                                  100500




                                                                                                                                                                                                        100500
                                                                                            90
                                                                                              .0

                                                                                              90.
                                                                                                  5




                                                                                                                                                                21500

                                                                                                                                                                        WALL
                                                                                                                                                 21100

                                                                                                                                                         EAVE
                                                                                                   91.
                                                                                                       0




                                                                                                                                                                               19100

                                                                                                                                                                                       DECK



                                                                                                                                                                                                        STAIRS
                                                                                                                                                                                              17100
                                                                                                      91.
                                                                                                          5

                                                                                                           92.0




                           SITE PLAN                                                                              92.5                   20100    270° 00' 00"
              1              1 : 200 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION              REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY               A     CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED         B                   CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED            C     PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT        D                   1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.                                                         NORTH
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                   REV                   SITE PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 03                     D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 4

                                                                                                           1800                              1820          2436                                     2435            1025        1025

                                                                                                                           2335                            2335                                   2335                   2340



                                                                                                                                                                                       UP




                                                                                                                  COL                               COL                                 COL                       COL                  COL




                                                                                                                                                     COL          COL                         COL


                                                                                                     COL                COL                         COL                                     COL                    COL                 COL


                                                                                                                                                                                             LDY




                                                                                        2020
                                                                                                                                                                                                                   COL         COL


                                                                                                     COL
                                                                                                                                                    COL                                     COL                    COL                 COL




                                                                                        2000
                                                                                                                                                                                                                               COL


                                                                                                     COL
                                                                                                                                                    COL                                             COL            COL         COL     COL

                                                                                        2030


                                                                                                     COL                                            COL
                                                                                                                                                                                                                               COL
                                                                                                                                                                                                    COL            COL                 COL




                                                                                                                         CLEAR FOR PARKING




                                                                                                                                                                   CLEAR FOR PARKING
                                                                                        2361




                                                                                                                                                    COL



                                                                                                     COL                                            COL                                                                        COL
                                                                                                                                                    COL                                             COL            COL                 COL




                                                                                                           COL                                      COL                                             COL                 COL            COL




                                                                                                                                                                                                  UP




                      PROPOSED COLUMN LAYOUT                                                                            3060                                      3376                                     1755               1754


         1              1 : 100 @A3                                                                                3620                                           3421                                   1450       1025        1025




ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A           CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                  CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C           PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                  1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.                                                                                    NORTH
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                              SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                 PROPOSED COLUMN LAYOUT
COMMENCEMENT OF WORK.
                                        887                 A - 04                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 5

                                                                                                                                                   10785

                                                                                                                          3850                     2800                       4135

                                                                                                               1200
                                                                                                                                                                                                           NEW STAIR BY CLIENT AFTER
                                                                                                                                                                                                                                             NOTES:
                                                                                                                                          A
                                                                                                                                        A - 09
                                                                                                                                                            UP                                             HOUSE DELIVERY, MAX 18
                                                                                                                                                                                                           RISERS IN ONE RUN                 - ALL DRAWINGS AND
                                                                                                                                                                                                                                             DIMENSIONS FOR HOUSE
                                                                                                                                                                                                                                             RAISE ONLY. CHECK ALL
                                                                                                                                                                                                                                             DIMENSIONS BEFORE
                                                                                                                                                                                                                                             COMPLETING OTHER
                                                                                                                                                                                                                                             BUILDING WORK.
                                                                                                                                        NEW DECK, NO ROOF                                                                                    - DIMENSIONS TAKE PRIORTIY
                                                                                                                                                                                                                                             OVER RL'S THAT MAY HAVE




                                                                                                                                                                                                 3600
                                                                                                                                                                                                                                             BEEN DERIVED FROM
                                                                                                                                                                                                                                             COUNCIL CONTOURS
                                                                                                                                                                                                                                             - LOCAL COUNCIL HEIGHT




                                                                                          1000




                                                                                                                                                                                                        1000
                                                                                                                                                                                                                                             LIMIT NOT TO BE EXCEEDED



                                                                                                                                                                                     BATH        2.03m
                                                                                                                                                                                       2x2       CEILING
                                                                                                                                                    KITCHEN
                                                                                                                                                          2.9 x 4.8



                                                                                                                       LIVING
                                                                                                                        3.6 x 6


                                                                                  10240


                                                                                          8640
                                                                                                                                                           BED 2




                                                                                                                                                                                                        9240
                                                                                                                                                           2.5 x 4.8
                                                                                                                                          SD
                                                                                                                                   SD
                                                                                                                                                                               SUN ROOM
                                                                                                                                                                                     1.6 x 7.3



                                                                                                                       ENTRY                  SD
                                                                                                                       2.3 x 3.6                           BED 1
                                                                                                                                                           3.4 x 4.8
                                                                                          600
                                                                                                 3000




                                                                                                                                                                                                        2400
                                                                                                                                        NEW DECK, NO ROOF




                                                                                                                                          A                            UP
                                                                                                                                                                                                                 NEW STAIR BY CLIENT AFTER
                                                                                                             600                        A - 09       10185                                                       HOUSE DELIVERY
                                                                                                                         3685                                          7100


                    PROPOSED FLOOR PLAN
       1              1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION                   REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY                    A           CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED              B                  CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED                 C           PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT             D                  1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.                                                               NORTH
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                                       SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                        REV                  PROPOSED FLOOR PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 05                           D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 6

                                                                                                                                    A
                                                                                                                                  A - 09




                                                           DOWNPIPES TO
                                                           TANK.



                                                           DOWNPIPES AND
                                                           GUTTERS AS
                                                           INDICATED.




                                                           METAL SHEETED
                                                           ROOF
                                                           THROUGHOUT




                                                                                                                                    A


                       PROPOSED ROOF PLAN
                                                                                                                                  A - 09



         1              1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.                                NORTH
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                PROPOSED ROOF PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 06                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 7

                                                                                                                                                                                                      NOTES:
                                                       8m AT ROOF RIDGE
                                                                                                                                                                                                      - ALL DRAWINGS AND
                                        8m AT DECK EDGE                                                                                                                                               DIMENSIONS FOR HOUSE
                                        7.5m AT DECK EDGE                                                                                                                                             RAISE ONLY. CHECK ALL
                                                                                                                                                                                                      DIMENSIONS BEFORE
            EAVES
            97000                       2100                                                                                                                                                          COMPLETING OTHER
                                                                                                                                                                                                      BUILDING WORK.
                                                                                                                                                                                                      - DIMENSIONS TAKE PRIORTIY
                                         2450
                                                                                                                                                                                                      OVER RL'S THAT MAY HAVE
                                                                                                                                                                                                      BEEN DERIVED FROM
                                                                                                                                                                                                      COUNCIL CONTOURS
                                                                                                                                                                                                      - LOCAL COUNCIL HEIGHT
            UPPER LEVEL                                                                                                                                                                               LIMIT NOT TO BE EXCEEDED
            94000
                                               3300




                                                                                                3500
                                                                      NGL



                          01 NORTH ELEVATION
             1              1 : 100 @A3                                                                                                                                                        8.5m                METAL SHEETED ROOF
                                                                                                                                                                                        8m

                                                                                                                                                                                                                   TIMBER WEATHERBOARDS

                                                                                                  EAVES
                                                                                                  97000




                                                                                                  UPPER LEVEL
                                                                                                  94000




                                                                                                                                                          2600




                                                                                                                                                                                        3300
                                                                                                                                                                              NGL


                                                                                                                 02 EAST ELEVATION
                                                                                                          2        1 : 100 @A3

ALL CONSTRUCTION TO BE IN                       DATE            DESCRIPTION         REV
ACCORDANCE WITH THE NCC & RELEVANT
                                          06.07.2021           PRELIMINARY           A       CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM       08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT        09.07.2021       TREE DETAILS ADDED        C       PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE             15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                               LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE      PRO             SHEET NUMBER              REV                PROPOSED ELEVATIONS 1
COMMENCEMENT OF WORK.
                                          887                  A - 07                D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 8

                                                                         8.5m
                                                                         8m



                                                                                                                                      METAL SHEETED ROOF

                                                                                                                                      TIMBER WEATHERBOARDS
     EAVES
     97000




     UPPER LEVEL
     94000




                                                                                                      2300
                                                 2500




                                                                              NGL




                         03 SOUTH ELEVATION
             1             1 : 100 @A3
                                                                                                                                                                                         8.5m
                                                                                                                                                                                         8m



                                                                                                                     EAVES
                                                                                                                     97000




                                                                                                                     UPPER LEVEL
                                                                                                                     94000




                                                                                                                                                                                                      2900
                                                                                                                                                                                  3500
                                                                                                                                                                                                NGL




                                                                                                                                          04 WEST ELEVATION
                                                                                                                              2            1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE                  DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021              PRELIMINARY           A      CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021      STAIRS & COLUMNS ADJUSTED     B              CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021          TREE DETAILS ADDED        C      PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021      ADDITIONAL BUILDING HEIGHT    D              1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                                LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO              SHEET NUMBER                REV             PROPOSED ELEVATIONS 2
COMMENCEMENT OF WORK.
                                        887                    A - 08                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 9

                                                                                                                     8.5m
                                                                                                                     8m



                                                                           EAVES
                                                                           97000




                                                                                                                                  KITCHEN             BED 2                BED 1



                                                                           UPPER LEVEL
                                                                           94000




                                                                                                                                                      NGL




                                                                                                SECTION A - BUILDING HEIGHT
                                                                                          A      1 : 100 @A3




ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION                 REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY                  A    CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED            B           CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED               C    PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT           D           1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                              SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                       REV          SECTIONS
COMMENCEMENT OF WORK.
                                        887                 A - 09                        D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 10

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                3D
COMMENCEMENT OF WORK.
                                        887                 A - 10                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 11

                                                                                                                                                                                                           NOTES:
                                                                                                                                                                                                            - ALL DRAWINGS AND
                                                                                                                                      10785
                                                                                                                                                                                                            DIMENSIONS FOR HOUSE
                                                                                                                                                                                                            RAISE ONLY. CHECK ALL
                                                                                                                   3850              2800                        4135                                       DIMENSIONS BEFORE
                                                                                                                                                                                                            COMPLETING OTHER
                                                                                                                                                                                                            BUILDING WORK.
                                                                                                                                                                                                            - DIMENSIONS TAKE PRIORTIY
                                                                                                                                                                                                            OVER RL'S THAT MAY HAVE
                                                                                                                                                                                                            BEEN DERIVED FROM




                                                                                          1000




                                                                                                                                                                                        1000
                                                                                                                                                                                                            COUNCIL CONTOURS
                                                                                                                                                                                                            - LOCAL COUNCIL HEIGHT
                                                                                                                                                                                                            LIMIT NOT TO BE EXCEEDED
                                                                                                                                                                        BATH      2.03m
                                                                                                                                                                         2x2      CEILING
                                                                                                                                       KITCHEN
                                                                                                                                            2.9 x 4.8



                                                                                                                LIVING
                                                                                                                 3.6 x 6




                                                                                  10240


                                                                                          8640
                                                                                                                                             BED 2




                                                                                                                                                                                        9240
                                                                                                                                              2.5 x 4.8



                                                                                                                                                                  SUN ROOM
                                                                                                                                                                        2 x 6.9



                                                                                                                ENTRY
                                                                                                                2.3 x 3.6                    BED 1
                                                                                                                                              3.4 x 4.8
                                                                                                                                                                                               EXISTING HOUSE 'STONEHURST
                                                                                                                                                                                               COTTAGE' LOCATED 25 TOOLAR
                                                                                                                                                                                               ST, TEWANTIN, QLD, 4565.
                                                                                          600




                                                                                                                  3685                                    7100




                   EXISTING FLOOR PLAN
      1              1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION                  REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY                   A     CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED             B            CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED                C     PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT            D            1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                                SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                        REV           EXISTING FLOOR PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 20                          D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 12

                                                                                                                                                                                        NOTES:
                                                                                                                                                                                        - ALL DRAWINGS AND
                                                                                                                                                                                        DIMENSIONS FOR HOUSE
                                                                                                                                                                                        RAISE ONLY. CHECK ALL
                                                                                                                                                                                        DIMENSIONS BEFORE
                                                                                                                                                                                        COMPLETING OTHER
                                                                                                                                                                                        BUILDING WORK.
                                                                                                                                                                                        - DIMENSIONS TAKE PRIORTIY
                                                                                                                                                                                        OVER RL'S THAT MAY HAVE
                                                                                                                                                                                        BEEN DERIVED FROM
                                                                                                                                                                                        COUNCIL CONTOURS
                                                                                                                                                                                        - LOCAL COUNCIL HEIGHT
                                                                                                                                                                                        LIMIT NOT TO BE EXCEEDED




                                                                 EXISTING METAL SHEETED ROOF




                      EXISTING ROOF PLAN
         1              1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION            REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY            A          CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED      B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED         C          PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT     D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                              SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                 REV                EXISTING ROOF PLAN
COMMENCEMENT OF WORK.
                                        887                 A - 21                   D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 13

                                                                                                        EXISTING METAL SHEETED ROOF




                                                                                                        EXISTING WEATHERBOARDS




                                        EXISTING NORTH ELEVATION
                         1              1 : 100 @A3




                                                                                                                                                 EXISTING METAL SHEETED ROOF



                                                                                                                                                 EXISTING WEATHERBOARDS




                                                                                                                                                                                EXISTING EAST ELEVATION
                                                                                                                                                                     2            1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                EXISTING ELEVATIONS
COMMENCEMENT OF WORK.
                                        887                 A - 22                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 14

                                                                                                                     EXISTING METAL SHEETED ROOF


                                                                                                                     EXISTING WEATHERBOARDS




                                        EXISTING SOUTH ELEVATION
                        1               1 : 100 @A3




                                                                                                                                                                                        EXISTING METAL SHEETED ROOF




                                                                                                                                                                                        EXISTING WEATHERBOARDS




                                                                                                                                      EXISTING WEST ELEVATION
                                                                                                                           2           1 : 100 @A3


ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                 CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                 1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                EXISTING ELEVATIONS
COMMENCEMENT OF WORK.
                                        887                 A - 23                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |

Page 15

                                                                                                                                                                                                           NOTES:
                                                                                                                                                                                                           - ALL DRAWINGS AND
                                                                                                                                                                                                           DIMENSIONS FOR HOUSE
                                                                                                                                                                                                           RAISE ONLY. CHECK ALL
                                                                                                                                                                                                           DIMENSIONS BEFORE
                                                                                                                                                                                                           COMPLETING OTHER
                                                                                                                                                                                                           BUILDING WORK.
                                                                                                                                                                                                           - DIMENSIONS TAKE PRIORTIY




                                                                                                      100 x 75




                                                                                                                   100 x 75




                                                                                                                              100 x 75




                                                                                                                                                            100 x 75




                                                                                                                                                                          100 x 75
                                                                                                                                                                                                           OVER RL'S THAT MAY HAVE
                                                                                                                                                                                                           BEEN DERIVED FROM
                                                                                                                                                                                                           COUNCIL CONTOURS
                                                                                           100 x 75
                                                                                                                                                                                                           - LOCAL COUNCIL HEIGHT
                                                                                                                                                                                                           LIMIT NOT TO BE EXCEEDED




                                                                                                                                                                                        EXISTING BEARERS




                                                                                           100 x 75




                                                                                           100 x 75




                      EXISTING FLOOR STRUCTURE
        1               1 : 100 @A3

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION          REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY           A         CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED     B                         CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED        C         PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT    D                         1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                            SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                REV                        EXISTING FLOOR STRUCTURE
COMMENCEMENT OF WORK.
                                        887                 A - 24                 D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |