      GENERAL NOTES:
       - DO NOT SCALE FROM THIS DRAWING -                   ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE
       WRITTEN DIMENSIONS TAKE PRECEDENCE                   ATTACK IN ACCORDANCE WITH AS 3660.1 AND A DURABLE
       OVER SCALE.                                          NOTICE SHALL BE PLACED IN THE METER BOX INDICATING
       - ANY DISCREPANCIES WHICH THE                        TYPE OF BARRIER AND REQUIRED PERIODICAL
       CONTRACTOR MAY FIND IN THIS DRAWING                  INSPECTIONS.
       MUST BE BROUGHT TO THE ATTENTION OF
       EVOKE ARCHITECTS PRIOR TO                            SAFETY GLAZING TO BE USED IN THE FOLLOWING CASES-
       COMMENCEMENT OF WORK. - VERIFY ALL                   i) ALL ROOMS WITHIN 500mm VERTICAL OF THE FLOOR
       DIMENSIONS PRIOR TO ORDERING OR SHOP                 ii) BATHROOMS- WITHIN 1500mm VERTICAL OF THE BATH
       FABRICATION.                                         BASE
       - SMOKE DETECTORS TO BE WIRED INTO                   iii) FULLY GLAZED DOORS
       ELECTRICITY MAINS AND TO COMPLY WITH                 iv) SHOWER SCREENS
       NCC, PART 3.7.5.                                     v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR
          SD                                                LEVEL
                                                            vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL
       - ALL GLAZING TO COMPLY WITH AS 1288-2006            VARY WITH MANUFACTURER, FLASHING ALL ROUND.
       GLASS IN BUILDINGS & AS 4055-2012 FOR
       WINDLOADING.                                         NOTE: GLAZING REQUIREMENTS MAY BE DIFFERENT FROM
       - ALL CONSTRUCTION TO BE IN ACCORDANCE               THAT STATED UNDER BUSHFIRE CATEGORY
       WITH THE RELEVANT AUSTRALIAN                         REQUIREMENTS REFER 'BAL RATING'
       STANDARDS, THE NATIONAL CONSTRUCTION
       CODE & LOCAL AUTHORITY REGULATIONS                   FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR
       - FOOTINGS HAVE BEEN DESIGNED IN                     EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS
       ACCORDANCE WITH ASSOCIATED SOIL TESTS                ARE TO BE LOCATED IN CLOSE PROXIMITY OF BOUNDARIES,
       AND/ OR ENGINEERS SPECIFICATIONS.                    A CHECK SURVEY BE CONDUCTED BY A LICENSED
       - DRAWINGS TO BE READ IN CONJUNCTION                 SURVEYOR.
       WITH ATTACHED ENGINEERS NOTES.
       - ARTICULATION JOINTS TO ENGINEERS                   ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
       DESIGN REPORT
       - LOH - WHERE INDICATED TO BE REMOVABLE              ALL WET AREAS TO COMPLY WITH NCC 3.8.1.2 AND AS 3740.
       DOORS WITH LIFT OFF HINGES IN                        SPLASH BACKS SHALL BE IMPERVIOUS FOR 150mm ABOVE
       ACCORDANCE WITH NCC 3.8.3                            SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE
       - REFER ENGINEER'S PLAN FOR EXPANSION                WALL.
       JOINT LOCATIONS
       - WATER PROOFING TO WET AREAS TO                     PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL
       COMPLY WITH NCC, PART 3.8.1                          AND HORIZONTAL AND WITHIN 300mm OF ARTICULATION
       - SMOKE ALARMS TO BE INTER-CONNECTED                 JOINTS. BRICK TIES TO BE STAINLESS STEEL.

       SUSTAINABILITY COMPLIANCE                            THERMAL INSULATION; INSULATION TO CEILING AND
                                                            REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY
       1. TRIPLE 'A' RATED SHOWER ROSES.                    RATING REFER SARKING REQUIREMENT UNDER BUSH FIRE
       2. DUAL FLUSH TOILETS (6 LITRE FULL FLUSH /          CATEGORY. BEDROOMS REQUIRE MINIMUM 10% LIGHT & 5%
       3 LITRE HALF FLUSH).                                 VENTILATION TO TOTAL FLOOR AREA.
       3. 500kpa WATER PRESSURE-LIMITING
       DEVICES.
       4. ENERGY EFFICIENT LIGHTING TO 80% OF               RELEVANT AUSTRALIAN STANDARDS
       DWELLING INTERNAL FLOOR SPACE.
                                                            - CONCRETE CONSTRUCTION TO COMPLY WITH
       TERMITE PROTECTION:                                  NATIONAL CONSTRUCTION CODE.
       TO AS3660-2017 "TERMSPEC" TERMITE
       MANAGEMENT SYSTEM TO ALL SLAB                        - TIMBER STRUCTURE STANDARD AS 1720.3- 2016
       PENETRATIONS AND PERIMETER OF SLAB.
       CONCRETE SLAB TO BE DESIGNED AND                     - TIMBER CONSTRUCTION AS1684 - 2010
       CONSTRUCTED IN ACCORDANCE WITH AS2870.               - MASONARY STRUCTURES AS4773-2010
       REFER ENGINEERS PLAN FOR EXPANSION JOINT             - CONCRETE STRUCTURES AS3600-2018
       LOCATIONS.                                           - CONCRETE ROOF TILES AS2049-2002
                                                            - RESIDENTIAL SLABS & FOOTINGS AS2870-2011
       SLAB:                                                - WINDOW & GLASS INSTALLATION AS2047 AND AS1288.                                                                     HOUSE RELOCATION TO:
       STEPDOWNS TO EXTERNAL SURFACES TO                    - BARRIERS FOR SUBTERRANEAN TERMITES TO
       COMPLY WITH THE NCC. CONCRETE SLABS,                 COMPLY WITH THE PROVISIONS OF PART 3.1.3 OF THE

                                                                                                                         1383 GREENRIDGE PINBARREN RD, PINBARREN
       PATHS & DRIVEWAYS NOT DESIGNED BY                    NCC AND WITH AS3660.1-2014
       ENGINEER ARE NOT PART OF THIS APPLICATION.           - WIND LOADS FOR HOUSING AS4055-2012
                                                            - STEEL STRUCTURES AS4100-2016
       PLUMBING:                                            - DAMP PROOF COURSE & FLASHINGS AS/NZS2904
       PLUMBER / DRAINER TO VERIFY ALL DIMENSIONS           - PROTECTION OF MASONRY WALL TIES TO COMPLY
       PRIOR TO POSITIONING UNDERSLAB POINTS.               WITH THE PROVISIONS OF PART 3.3.3.2 OF THE NCC.
       MEASUREMENTS MAY VARY. FLOOR WASTE                   - PROTECTION OF LINTELS IN MASONRY TO COMPLY
       FIXTURES TO BE POSITIONED AT THE TIME OF             WITH THE PROVISIONS OF PART 3.3.3.4 OF THE NCC.
       CONSTRUCTION.

ALL CONSTRUCTION TO BE IN                 DATE               DESCRIPTION             REV
ACCORDANCE WITH THE NCC & RELEVANT
                                        06.07.2021           PRELIMINARY              A        CLIENT NAME:
AUSTRALIAN STANDARDS. FULL
STRUCTURAL CERTIFICATION IS REQUIRED.
DO NOT SCALE FROM DRAWINGS. CONFIRM     08.07.2021   STAIRS & COLUMNS ADJUSTED        B                CHRISTINE WINKLE & IAN POLLOCK
ALL DIMENSIONS ON SITE PRIOR TO
COMMENCING ANY FABRICATION, SETOUT      09.07.2021       TREE DETAILS ADDED           C        PROJECT ADDRESS:
OR WORK. ANY COSTS ARISING FROM
INCORRECT DIMENSIONING IS THE           15.07.2021   ADDITIONAL BUILDING HEIGHT       D                1383 GREENRIDGE PINBARREN RD, PINBARREN, QLD, 4568.
RESPONSIBILITY OF THE CONTRACTOR IF                             LINES
EVOKE ARCHITECTS IS NOT CONTACTED                                                              SHEET NAME:
PRIOR TO CONSTRUCTION. VERIFY
LOCATION OF EXISTING SERVICES BEFORE    PRO           SHEET NUMBER                  REV                COVER SHEET
COMMENCEMENT OF WORK.
                                        887                 A - 01                    D
COPYRIGHT EVOKE ARCHITECTS ALL RIGHTS RESERVED. THIS WORK CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF EVOKE ARCHITECTS.
© EVOKE ARCHITECTS 2021 - | ALVIN: 0421 244 897 DARCY: 0421 159 555 | E: [email protected] |
Log in to download the original file

Architecturals REV D.pdf · 2.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.