                                                                                                                                                                                                                                                                                                                                                                                                                TEAL STREET
GENERAL NOTES                                                                    SANITARY PLUMBING & DRAINAGE                                                  LINE TYPE LEGEND                                                                      SITE CLASSIFICATION:
1.   OBTAIN ALL NECESSARY APPROVALS FROM ALL AUTHORITIES HAVING                  1.   ALL SANITARY DRAINAGE SHALL BE 100 DIA. AT 1.65% FALL U.N.O.
                                                                                                                                                               HOUSE DRAINAGE                                                                        CLASS 'P/S' (Y's 20mm)
     JURISDICTION AND PAY ALL FEES DUE. COMMENCEMENT OF PLUMBING AND                                                                                           VENT
     DRAINAGE WORKS SHALL NOT PROCEED UNTIL ALL NECESSARY APPROVALS              2.   MINIMUM SIZE OF ACCESS PANELS SHALL BE 300mm X 300mm.                    STORMWATER DRAINAGE
     HAVE BEEN PROVIDED BY THE LOCAL AUTHORITY
                                                                                 3.   ANY FLOOR WASTE GULLY LOCATED IN A LAUNDRY SHALL BE PROVIDED WITH AN     COLD WATER
                                                                                                                                                                                                                                                     INSTALLATION GUIDELINE
2.   ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY               ANTI-FOAMING GRATE SYSTEM.                                               HOT WATER                                                                                  NOTE: THE FOLLOWING NOTES & DETAILS ARE A GUIDE ONLY FOR
     HAVING JURISDICTION AND WITH THE REQUIREMENTS OF ALL RELEVANT                                                                                                                                                                                        ARTICULATION OF SANITARY PLUMBING & DRAINAGE AND SHALL BE READ IN
     AUSTRALIAN STANDARDS & PLUMBING & DRAINAGE ACT 2018.                             MATERIALS:                                                               TEMPERED WATER
                                                                                                                                                                                                                                                          CONJUNCTION WITH AS/NZS 3500, AS2870, MANUFACTURERS INSTALLATION
                                                                                                                                                               SUBSOIL DRAINAGE                                                                           RECOMMENDATIONS & ANY OTHER RELEVANT STANDARDS, & REQUIREMENTS
3.   THE CONTRACTOR IS TO ASCERTAIN THE EXACT LOCATION OF ALL EXISTING                HOUSE DRAINAGE                   -    PVC CLASS DWV                                                                                                                 OF THE N.C.C.
     SERVICES PRIOR TO COMMENCEMENT OF CONSTRUCTION AND CONFIRM INVERT                                                                                         RISING MAIN
     LEVELS AND LOCATIONS OF ALL AUTHORITY CONNECTIONS PRIOR TO THE                   SOIL, WASTE AND VENT PIPE        -    PVC CLASS DWV                      EXISTING WATER                                                                        1.   ALL SEWER & STORM WATER SERVICES SHALL BE CONSTRUCTED IN
     INSTALLATION OF ANY ASSOCIATED SERVICES. THE CONTRACTOR SHALL BE                                                                                                                                                                                     ACCORDANCE WITH AS/NZS 3500 & THE REQUIREMENTS OF AS2870 SECTION 5:
     RESPONSIBLE FOR THE COST OF RECTIFICATION OF ANY DAMAGE WHICH MAY                                                                                         EXISTING SEWER
                                                                                                                                                                                                                                                          CLAUSE 5.5 & SECTION 6: CLAUSE 6.6. ARTICULATION & EXPANSION JOINTS ARE
     OCCUR. NO OPINION IS EXPRESSED AS TO THE ACCURACY OF THE EXISTING                                                                                         EXISTING HOUSE DRAIN                                                                       TO BE INSTALLED TO ACCOMMODATE MOVEMENT IN ALL PIPE WORK WITHIN 3m
     SERVICES SHOWN ON THIS DRAWING.                                             STORMWATER & DOWNPIPES                                                        EXISTING STORMWATER                                                                        OF THE DWELLING & SHALL COMPLY WITH AS1260.
4.   THESE DRAWINGS ARE A DIAGRAMMATIC REPRESENTATION OF A PROPOSED                                                                                            BEAM PENETRATION                                                                      2.   PLUMBING & DRAINAGE UNDER THE SLAB SHALL BE AVOIDED WHERE PRACTICAL
                                                                                 1.   ALL STORMWATER DRAINAGE SHALL BE 100 DIA. AT 1% FALL U.N.O.
     PLUMBING AND DRAINAGE INSTALLATION. USE DIMENSIONED ARCHITECTURAL                                                                                                                                                                                    (REFER AS/NZS 3500 CLAUSE 4.10).




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   N ESP
                                                                                                                                                               CAST IN SLAB
     DRAWINGS FOR SET OUT OF PENETRATIONS RELATING TO PLUMBING FIXTURES.
                                                                                 2.   Ø100 DOWNPIPES ARE MINIMUM REQUIRED CROSS-SECTIONAL AREA.
     IT IS THE RESPONSIBILITY OF THE INSTALLER TO CO-ORDINATE THE ON-SITE                                                                                                                                                                            3.   GRADES IN PIPE WORK ON H, E & P SITES SHOULD HAVE A MINIMUM GRADE OF
     INSTALLATION WITH OTHER SERVICES INSTALLATIONS, STRUCTURE AND THE                MATERIALS:                                                                                                                                                          1:40 WITHIN THE BUILDING AND 1:60 ELSEWHERE. GRADES IN FLEXIBLE FITTINGS
     LIKE. DO NOT SCALE THESE DRAWINGS.                                                                                                                                                                                                                   TO BE SET AT THE MINIMUM GRADE.
                                                                                      DOWNPIPES                        -    PVC CLASS DWV
                                                                                                                                                               SYMBOLS




                                                                                                                                                                                                                                                                                                                                                                                                                                                                              PEREGIA
5.   'AS-CONSTRUCTED' DRAWINGS- WHERE REQUIRED BY THE LOCAL AUTHORITY-                                                                                                                                                                               4.   ALL EXPANSION & ARTICULATION JOINTS SHALL BE INSTALLED IN ACCORDANCE
     ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL                   STORMWATER                       -    PVC CLASS SW HEAVY UNO                                                                                                        WITH THE MANUFACTURER’S SPECIFICATIONS. ALL JOINTS SHALL BE SET AT THE
                                                                                                                                                                                                               FLOW DIRECTION
     RECORD ALL CHANGES TO ORIGINAL DESIGN AND ALLOW ALL COSTS FOR THE                                                                                                                                                                                    MID POINT OF STRAIGHT SECTIONS TO ALLOW FOR MAXIMUM MOVEMENT IN
     PREPARATION OF 'AS-CONSTRUCTED' DRAWINGS.                                        SUBSOIL DRAINAGE                 -    PERFORATED PVC (DN100 U.N.O.) IN                                           SERVICE & ITEM NUMBER                 LABEL        EITHER DIRECTION.
                                                                                                                                                               WATER/FIRE SERVICE
                                                                                                                            FILTER SOCK                                                                                        SIZE           SIZE
6.   AS A CONDITION OF TENDERING, THE CONTRACTOR SHALL VISIT THE SITE AND                                                                                                                                                                            5.   “SWIVEL JOINTS” SHALL NOT BE USED AS A BEND TO ACHIEVE CORRECT FALLS.
     SHALL BE DEEMED TO BE FULLY AWARE OF SITE CONDITIONS. ANY CLAIM FOR              AIRCON CONDENSATE                -    25Ø PVC WITH 10mm BRADFLEX                                                         FLOW DIRECTION                                                                                                              14.50
                                                                                                                                                                                                                                                                                                                                                   14.00
                                                                                                                                                                                                                                                                                                                                                           13.50
     VARIATION ON THE BASIS OF LACK OF KNOWLEDGE OF SITE CONDITIONS SHALL                                                   INSULATION                                                                                                               6.   DETAIL & SUPPORT OF TRAPS AT THE O.R.G. SHALL BE CONSIDERED ON SITE TO
                                                                                                                                                                                                                                                                                                                                                                   13.00
                                                                                                                                                               ELEVATED PIPEWORK                                  EPD           S                                                                                                                                          12.50
     NOT BE ACCEPTED.                                                                                                                                                                                                                                     ALLOW FOR POTENTIAL MOVEMENTS INCLUDING ISOLATION & ARTICULATION                                                         12.00
                                                                                                                                                               DROPPER/STACK                                      SIZE         SIZE                                                                                                                                                        11.50
                                                                                                                                                                                                                                                          ASSOCIATED WITH PATHS & PAVEMENTS, THE O.R.G. SHOULD BE CAST IN                                                                                    11.00
7.   WHERE A PARTICULAR MANUFACTURERS PRODUCT IS SPECIFIED OR NOTED,                                                                                                                                                     IWD                              CONCRETE MONOLITHICALLY WITH THE FOOTING SYSTEM ON CLASS H, E & P                                                                                                10.50
                                                                                                                                                               INDEPENDENT WASTE DROPPER
     OTHER MANUFACTURERS PRODUCTS MAY BE SUBSTITUTED. SUBSTITUTED
     PRODUCTS MUST HAVE PERFORMANCE AND LONGETIVITY CRITERIA EQUAL TO            ABBREVIATIONS                                                                                                                                                            SITES.                                                                                                                                                                              10.00
                                                                                                                                                                                                                                                                                                                                                                                                                                                          9.50


     OR GREATER THAN THE SPECIFIED PRODUCT. DOCUMENTED PROOF OF SAID
     CRITERIA MAY BE REQUIRED.                                                   AAV     -      AIR ADMITTANCE VALVE                                           EXPANSION JOINT                                                                       7.   ALL PVC PIPE WORK PASSING THROUGH CONCRETE SHALL HAVE A MINIMUM OF
                                                                                                                                                                                                                                                          40mm LAGGING UNO.
                                                                                                                                                                                                                                                                                                                                     LOCATION PLAN
                                                                                 AP      -      ACCESS PANEL                                                                                                                                                                                                                         NTS
8.   USE EXISTING HOUSE DRAIN & WATER CONNECTIONS, PAY ANY AND ALL FEES          BTH     -      BATH                                                           FLOOR WASTE GULLY
                                                                                                                                                                                                                                                     8.   STORM WATER SYSTEMS THAT COLLECT ROOF WATER & SURFACE WATER ARE
     DUE.                                                                        B       -      BASIN
                                                                                                                                                                                                                                                          REQUIRED TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AS/NZS
                                                                                 BV
                                                                                 CV
                                                                                         -
                                                                                         -
                                                                                                BALL VALVE
                                                                                                CHECK VALVE
                                                                                                                                                               STOP TAP                                                                                   3500                                                                       RPD
                                                                                 CW      -      COLD WATER                                                                                                                                                                                                                           LOT: 304
                                                                                                                                                               ISOLATION VALVE                                                                       9.   THE USE OF CORRUGATED FLEXIBLE PVC PIPE PRODUCTS SHOULD BE AVOIDED
                                                                                 CWM     -      CLOTHES WASHING MACHINE                                                                                                                                                                                                              PLAN: P93112
WATER SUPPLY                                                                     DP      -      DOWNPIPE
                                                                                                                                                                                                                                                          ON CLASS H & E SITES AS THEY ARE NOT ABLE TO EXPAND LONGITUDINALLY TO
                                                                                                                                                               GATEVALVE PADLOCKED OPEN                                                                   ACCOMMODATE POTENTIAL VERTICAL & LATERAL MOVEMENTS AT THE SLAB OR
                                                                                 DuCV    -      DUAL CHECK VALVE
1.   CW & HW TO INDIVIDUAL POINTS IS 15Ø U.N.O.                                                                                                                                                                                                           FOOTING EDGE UNLESS SPECIFICALLY DESIGNED BY THE MANUFACTURER.
                                                                                 DWM     -      DISH WASHING MACHINE
                                                                                 EJ      -      EXPANSION JOINT                                                CHECK VALVE
2.   HW IS 15Ø THROUGHOUT U.N.O.                                                                                                                                                                                                                     10. ALL PIPE WORK INCLUDING STORM WATER FITTINGS & ADAPTERS SHALL BE
                                                                                 EPD     -      ELEVATED PIPEWORK DROPPER
                                                                                                                                                               WATER METER
                                                                                                                                                                                                                                                         PROTECTED FROM MECHANICAL DAMAGE.
                                                                                 FF      -      FROG FLAP
3.   CW TO MORE THAN 1 POINT SHALL BE 20Ø OR GREATER                             FFL     -      FINISHED FLOOR LEVEL
                                                                                                                                                                                                                                                     11. TERMITE PROTECTION IS NOT SHOWN ON THESE DRAWINGS. REFER TO THE
                                                                                 FU      -      FIXTURE UNITS                                                  END CAP
4.   EXTERNAL HOSE COCKS SHALL BE SUPPLIED WITH 20Ø (MIN) FEED                                                                                                                                                                                           BUILDING DESIGNER FOR DETAILS.
                                                                                 FS      -      FIRE SERVICE
                                                                                 FSL     -      FINISHED SURFACE LEVEL
5.   SIZING (EG 20Ø) REFERS TO TYPE B COPPER TUBE. REFER AS 3500.1.2 TABLE 1.1                                                                                 PUMP                                                                                  12. ALL DETAILS ARE INDICATIVE ONLY. REFER TO STRUCTRUAL ENGINEERS
                                                                                 FW      -      FLOOR WASTE
     FOR EQUIVALENT PIPE SIZE IN OTHER APPROVED MATERIALS.                                                                                                                                                                                               DRAWINGS FOR DETAILS ON SLAB AND FOOTING LAYOUT
                                                                                 FWG     -      FLOOR WASTE GULLY
                                                                                 HC      -      HOSE COCK                                                      250 x 250 FIELD INLET PIT WITH
6.   IN NO CASE SHALL A 15Ø COLD BRANCH EXCEED 3m IN LENGTH                                                                                                    ALUMINIUM GRATE EQUAL TO EVERHARD
                                                                                                                                                                                                                                                     13. PROVISIONS SHALL BE MADE FOR THE CONNECTION OF OVERFLOW OR WATER
                                                                                 HCB     -      HOUSE CONNECTION BRANCH
                                                                                                                                                               EasyDRAIN                                                                                 DISCHARGE FROM FIXTURES SUCH AS H.W.S. AND A.C. TO A DRAIN AS REQUIRED
                                                                                 HD      -      HEAVY DUTY
7.   POSITION SERVICES IN CEILING SPACES AND WALL FRAMING U.N.O.                                                                                                                                                                                         BY THE RELEVANT LOCAL AUTHORITY.
                                                                                 HL      -      HIGH LEVEL
                                                                                                                                                               450 x 450 CATCHPIT HAVING A HDG
                                                                                 HW      -      HOT WATER
8.   JOINTS IN PRESSURED WATER SERVICE PIPES UNDER FLOOR SLABS ARE NOT                                                                                         SUMP GRATE & FRAME EQUAL TO                                                           14. ADDITIONAL EXPANSION & SWIVEL JOINT TO BE INSTALLED AT SEWER
                                                                                 HWU     -      HOT WATER UNIT                                                 WEBFORGE MODEL MSG44
     PERMITTED.                                                                                                                                                                                                                                          CONNECTION POINT,OSTP, OR GREASE TRAP
                                                                                 IL      -      INVERT LEVEL
                                                                                 IO      -      INSPECTION OPENING                                             600 x 600 CATCHPIT HAVING A HDG
9.   ALL IN-GROUND VALVES AND OR METERS SHALL BE ENCLOSED IN APPROVED                                                                                          SUMP GRATE & FRAME EQUAL TO                                                           15. DRAINAGE LOCATED IN UNCONTROLLED FILL AREAS EXCEEDING 800mm SHALL BE
                                                                                 IOS     -      INSPECTION OPENING TO SURFACE
     PATH BOXES.                                                                                                                                               WEBFORGE MODEL MSG66                                                                      SUPPORTED TO THE UNDERSIDE OF SLAB WITH STAINLESS STEEL STRAPS AT
                                                                                 IV      -      ISOLATION VALVE
                                                                                                                                                                                                                                                         1.2m CENTRES.
                                                                                 LL      -      LOW LEVEL                                                      300 TRENCH DRAIN HAVING A HDG
10. FLOW RESTRICTION DEVICES SHALL BE FITTED WHERE TAP FLOW RATES ARE            NRV     -      NON RETURN VALVE                                               GRATE & FRAME EQUAL TO
    NOT SELF-LIMITING. DEVICES SHALL HAVE A MINIMUM OF 4 LARGE WATERWAY          OF      -      OVERFLOW                                                       WEBFORGE MODEL MTG30                                                                           EXPECTED MINIMUM REQUIREMENTS FOR
    PORTS TO REDUCE BLOCKAGES. (CONSERV OR SIMILAR) THEY SHALL BE USED           ORG     -      OVERFLOW RELIEF GULLY                                          BALCONY OUTLET EQUAL TO                                                                     EXPANSION & ALLOWABLE ROTATION IN FITTINGS
    TO RESTRICT FLOWS TO BASINS, SINKS, SHOWERS & TUBS TO A MAXIMUM FLOW         PBO     -      PLANTER BOX OUTLET                                             SPS 100 SQUARE VARI-LEVEL SIDE
    OF 9L/min.                                                                   PRV     -      PRESSURE REDUCING VALVE                                                                                                       BO1                              SITE CLASS    MIN. EXPANSION REQD   ALLOWABLE ROT.
                                                                                                                                                               OUTLET DRAIN (50mm OUTLET)
                                                                                 RAG     -      REGISTERED AIR GAP                                             MODEL: Q100N/C90                                                                                    E                150mm                15°
11. HOT WATER INSULATION SHALL FULLY COMPLY WITH AS3500.4-2018 SECTION 8.        RHS     -      RECTANGULAR HOLLOW SECTION                                     RAINWATER OUTLET EQUAL TO
    MINIMUM R VALUE OF 0.3.                                                      RL      -      REDUCED LEVEL                                                                                                                 RWO1                                 H2               75mm                 15°
                                                                                                                                                               SPS TRUFLOW 100mm WITH CLASS C
                                                                                 RPD     -      REAL PROPERTY DESCRIPTION                                      GRATE. MODEL: TBS100F                                                                               H1               60mm                 15°
12. TAP OUTLET POINTS SHOWN ON THE PLAN ARE INDICATIVE ONLY. REFER TO            S       -      SINK
    ARCHITECTURAL AND/OR END CLIENT SPECIFICATIONS FOR PRECISE OUTLET            SHR     -      SHOWER                                                         DOMED RAINWATER OUTLET EQUAL TO                                                                     P          DEPENDENT ON SITE          N/A
    LOCATIONS.                                                                   SL      -      SURFACE LEVEL                                                  SPS TRUFLO 100mm                                               RWO2
                                                                                                                                                               MODEL: TIB100D2
                                                                                 STY     -      SAFE TRAY
13. INSTALL COLD WATER CONTROLS AND PIPING ON THE INLET SIDE OF A HWU TO         TD      -      TUNDISH                                                        PLANTER BOX OUTLET EQUAL TO
    COMPLY WITH AS 3500.4 AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE         TTD     -      TRAPPED TUNDISH                                                SPS TRUFLO 100mm RWO WITH ALL
                                                                                                                                                               PURPOSE PLANTER BOX ADAPTOR                                    PBO1
    LOCAL AUTHORITY                                                              TG      -      TEST GATE
                                                                                                                                                               MODEL: TIA 100PB
                                                                                 TPV     -      TEMPERING VALVE
                                                                                                                                                               PLANTER BOX OUTLET EQUAL TO
14. RETICULATE HOT WATER TO ALL FIXTURES EXCEPT HOSE COCKS, DISHWASHERS          TR      -      TROUGH                                                         SPS TRUFLO 100mm RWO WITH ALL                                  PBO2
    AND WATER CLOSETS                                                            UNO     -      UNLESS NOTED OTHERWISE                                         PURPOSE PLANTER BOX ADAPTOR
                                                                                 UW      -      UNITYWATER                                                     MODEL: TIA 80PB
15. PROVIDE 65° HOT WATER TO SINKS AND LAUNDRYS ONLY, ALL OTHER FIXTURES         VB      -      VACUUM BREAKER
    TO BE FITTED WITH A TEMPERING DEVICE AND SET TEMPERATURE AS                  WC      -      WATER CLOSET
    NOMINATED BELOW -

     15.1   THERMOSTATIC MIXING VALVE SET TO 45°C FOR HOT & COLD DISABLED
            FACILITY HYGIENE FIXTURES                                                                                                                                             FIXTURE LEGEND
     15.2   TEMPERING VALVE SET TO 50°C TO ALL OTHER HOT & COLD HYGIENE
            FIXTURES
                                                                                                                                                               WATER CLOSET                                                                                                                           LAGGING THICKNESS: 40mm
16. TAPS OR OTHER OPERATIONAL CONTROLS PROVIDED IN SANITARY FACILITIES                                                                                                                                                                                                                                FOR H,E & P SITES UNLESS
    FOR PEOPLE WITH DISABILITIES SHALL BE IN ACCORDANCE WITH -                                                                                                                                                                                                                                        NOTED OTHERWISE

     16.1   AS1428.1 (2001) & AS1428.2 FOR PASSENGER USE AREAS OF CLASS 9b AND                                                                                                                                                                                                          "SWIVEL/KNUCKLE JOINT"
            CLASS 10 PUBLIC TRANSPORT BUILDINGS; AND                                                                                                           BASIN                                                                                                                    INSTALLED TO MANUFACTURER'S
                                                                                                                                                                                                                                                                                        RECOMMENDATIONS
     16.2   AS1428.1 (2009) FOR ALL OTHER BUILDINGS

17. PROVIDE A 500kPa PRESSURE REDUCING VALVE IMMEDIATELY DOWNSTREAM OF                                                                                         SHOWER                                                                                                                   "EXPANSION JOINT" (LUBRICATED
    THE DOMESTIC SERVICE ISOLATING VALVE                                                                                                                                                                                                                                                WRAPPED IN 2 LAYERS OF 200 MICRON
                                                                                                                                                                                                                                                                                        POLYTHENE & SEALED WITH
     MATERIALS:                                                                                                                                                                                                                                                                         PRESSURE SENSITIVE TAPE TO
                                                                                                                                                                                                                                                                                        EXCLUDE SOIL PARTICLES)
                                                                                                                                                               SINK
     ACRONITRILE BUTADIENE STYRENE, TYPE B COPPER, COPPER ALLOY STAINLESS
     STEEL, POLYBUTYLENE, POLYETHYLENE, CROSS-LINKED POLYETHYLENE, HIGH
     DENSITY POLYETHYLENE. WITH LIMITATIONS AS STATED IN AS 3500.

                                                                                                                                                               BATH
                                                                                                                                                                                                                                                             TYPICAL PIPE THROUGH BASEMENT
     ALL HOT AND COLD WATER SERVICES LOCATED WITHIN A CONCRETE SLAB SHALL
     BE ENCASED IN CONDUIT FOR THE FULL DISTANCE INCLUDING ENTRIES & EXITS                                                                                                                                                                                   WALL DETAIL
     FROM THE SLAB FACE/ FORMWORK. ACRONITRILE BUTADIENE STYRENE SHALL
                                                                                                                                                                                                                                                             NTS
     NOT BE LOCATED IN CONCRETE SLABS/WALLS
                                                                                                                                                               LAUNDRY TUB




       BACKFLOW PREVENTION TABLE                                                                                                                               WASHING MACHINE




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              10
TYPE              FORM OF POTENTIAL CROSS CONNECTION                   DEVICE

CONTAINMENT       SITE                                                 DuCV
                                                                                                                                                               OUTDOOR BATH
INDIVIDUAL        HOSE COCK                                            VB

NOTE:
PROVIDE ADDITIONAL BACKFLOW DEVICES TO ALL COMMERCIAL FIXTURES IN ACCORDANCE
WITH MANUFACTURERS AND / OR LOCAL AUTHORITY REQUIREMENTS.
                                                                                                                                                                                                                                                                                                                                                                                                    A      07.06.22                APPROVAL                           JS
                                                                                                                                                                                                                                                                                                                                                                                                   ISSUE    DATE                   REVISION                        DESIGNED

                                                                                                                                                                       FIXTURE WASTE SIZE TABLE
                                                                                                                                                                                                                                                                                                                                                                                                                         SPICE CONSULTING
                                                                                                                                                               WATER CLOSET TO DRAIN                                                  Ø100                                                                                                                                                                               CONSTRUCTION HYDRAULICS CONSULTANTS




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              5
                                                                                                                                                               BASIN TO DRAIN                                                         Ø65                                                                                                                                                                                PO BOX 1406 BUDERIM QLD 4556
                                                                                                                                                               SINK TO DRAIN                                                          Ø65                                                                                                                                                                        QBCC    Telephone: 0428 434 219
                                                                                                                                                               OVERFLOW RELIEF GULLY TO DRAIN                                         Ø100                                                                                                                                                                     1124616   Email: [email protected]
                                                                                                                                                                                                                                                                                                                                                                                                   CLIENT
                                                                                                                                                               VENT TO DRAIN                                                          Ø100                                                                                                                                                                                   R & A MURRAY
                                                                                                                                                               ALL SANITARY DRAINAGE SHALL BE 100 DIA. AT 1.65% FALL U.N.O.
                                                                                                                                                                                                                                                                                                                                                                                                   ASSOCIATED CONSULTANT

                                                                                                                                                                                                                                                                                                                                                                                                   DRAWING :                                          LEVEL: AHD
                                                                                                                                                                                                                                                                                                                                                                                                     GENERAL NOTES & LOCATION PLAN                    SCALE:
                                                                                                                                                                                                                                                                                                                                                                                                                                                      A1 - 1: 100
                                                                                                                                                                                                                                                                                                                                                                                                                                                      A3 - 1: 200




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              0
                                                                                                                                                                                                                                                                                                                                                                                                   PROJECT:                                                STATUS                   ISSUE :

                                                                                                                                                                                                                                                                                                                                                                                                     PROPOED RESIDENCE at                                        APPROVAL
                                                                                                                                                                                                                                                                                                                                                                                                     34 PEREGIAN ESPLANADE,                                DWG. No.

                                                                                                                                                                                                                                                                                                                                                                                                                                                                 2373-01
                                                                                                                                                                                                                                                                                                                                                                                                                                                                         A
                                                                                                                                                                                                                                                                                                                                                                                                     PEREGIAN BEACH
                                                                                                                                                                                                                                                                                                                                                                                                                                                           SHEET :
                                                                                                                                                                                                                                                                                                                                                                                                                                                                     01       OF        03
Log in to download the original file

2373 Hydraulics 07.06.22.pdf · 730 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.