15679 Traffic Impact Assessment Report
Proposed Medical Development, Noosaville
Medicentre Properties Pty Ltd
November 2015
6. ACCESS ARRANGEMENTS
Access to the site will be from two access driveways. All access driveways must
comply with standard drawings SEQ R-051 for heavy duty vehicle crossovers. The
access driveways from Goodchap Street will be a Type B with a minimum width of
6.0m.
Figure 9 –Standard Commercial Driveways R-051
The minimum sight lines for pedestrian safety at driveway accesses require a clear
sight triangle from the property. These criteria must be achieved for the access to the
site and it is recommended that landscape treatments must be low planting and
less than 1.0m in height.
Figure 10 – Pedestrian Sight Visibility Requirements at Driveways