Original source · versioned page text
Bushfire Hazard Assessment & Management Plan v2 - 48-59 Kabi Road COOTHARABA
Plans and drawings: the text below has words only, no drawings.
Bushfire Hazard Assessment & Management Plan v2 NCES REF: J001061 Lot 7 on RP216403, Lot 394 on M371117, and Lot 650 on M37380 – 48-59 Kabi Road, Cootharaba footprint must be separated from the closest edge of an adjacent mapped medium, high or very-high potential bushfire intensity area by a distance (APZ width) that achieves a radiant heat flux level of 10 kW/m2 or less at all development footprint boundaries. The risk assessment performed in Section 4.2 herein identifies that the entire development footprint boundary is separated by sufficient distance to achieve <10kW/m² RHF from the High and Medium Potential Intensity Areas associated with the VHC 8.1, VHC 9.1, and VHC 36.1 vegetation hence satisfy the vulnerable use setback criteria. Therefore, no specific APZ’s are required about the proposed infrastructure locations whilst site conditions remain as they are detailed herein. It is nonetheless recommended that any future landscaping does not exacerbate the bushfire hazard risk on the site and result in separation between infrastrcuture and hazardous vegetation that generates non-compliance with the vulnerable use setback criteria. 5.3 Water Supply The availability of a reliable water supply for firefighting purposes is a vital tool in the defence of bushfire impact. Reticulated water supply is currently not available within the site nor proposed to be connected to the site. Therefore, any proposed buildings in the confirmed bushfire prone areas (refer BF03) within the site require provision of a readily accessible on- site emergency static water supply in accordance with Assessment Benchmark 4 of the SPP Bushfire 2019. Assessment Benchmark 4 references the QFES 2019 Bushfire Resilient Communities document for information regarding appropriate static water supply. Section 9.1 of Bushfire Resilient Communities’ states: An appropriate static water supply (in bushfire prone areas where reticulated supply is not provided) to support effective emergency services response includes a water tank that is available solely for firefighting purposes and can be accessed by firefighting appliances. The water tank is to be provided within 10 metres of each building (other than a class 10 building), which: a) is either below ground level or of non-flammable construction; b) has a take-off connection at a level that allows the following dedicated, static water supply to be left available for access by firefighters: i.10,000 litres for residential buildings; It is therefore recommended that a dedicated 10,000 litres should be made available to the each of the proposed new buildings located within the confirmed bushfire prone area, which only applies to the proposed ‘roofed amenities and kitchenette’ building in the east, and this volume should be reserved for firefighting purposes only. Plate 20 outlines an example of how this can be achieved. Plate 20 – Example Static Water Supply tank design for firefighting purposes (Source: Kingspan Group 2021) © 2023 28
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.