Council archive · source document
Approved Plans MCU20-0087 · MCU20/0087
Plans and drawings: the text below has words only, no drawings.
1000 4190 3690 3690 8750 8960
90
1
90
2 90 90
4 90 90 90 90 90 90 90 90 90
1000 1000 3000 510 3000 510 3000 510 1090 1850 6450 4180
3
90 7750 90
Elevations
CARPORT
BUSH FIRE RATING BAL12.5
6620
6620
7930 RAMP DOWN
UPPER FLOOR PLAN
SCALE 1:100 ALL TRADES PEOPLE TO WORK
NORTH SAFELY ON THIS SITE
Upper Floor Plan : 243.35 Sq.m. 50mm MIN STEP DOWN
Tiled Deck Roofed : 20.20 Sq.m. (not including non roofed deck areas - approx 37.8 Sq.m.) 90 1760
Carport & Portico : 58.46 Sq.m.
Total Upper Floor Roofed Areas : 322.01 Sq.m.
90
90
Total Lower & Upper Floor Areas : 369.71 Sq.m. (plus undercroft and non roofed areas)
0
820
1840
1840
1700
820
90
90
KITCHEN
90
3750
FW
1100 600
1000 1000
FRIDGE
1000
1400
1400
5000
1310
SPACE
WC SHR PORTICO
LAUNDRY
90
3450 bath
720
BUTLERS
1310 90
FW FW
fridge
900
920
HB
21280
BATH
1400
4050
1800
90
BED 2
1510
90
HB
90
820
90
ENTRY
ROBE
1970
WM
ROBE
BED 3
3690
90
90
720
1400
1310
90
90
1340 510
90
ROBE 2/720CS LINEN LINEN
12680
90
720
510
2400
1000mm high walls
3680
BED 4
90
90
920
LINEN
SHR
620
1200
2160
2/720CS
2070
14570
90
WC
DINING
1300
LINEN
PF GATE
820
90
ENSUITE
90
820
90
8660
90
2/720CS
2880
7410
7410
HB
1800
FW Y
O NL TILED DECK
S TS -
820CS
E PO
HB ATIV
NOOSA COUNCIL
5090
OR ROOFED
DEC
robe
90
APPROVED PLAN
900
BALUSTRADE
BALUSTRADE PF GATE
50mm MIN STEP DOWN
LOUNGE
MCU20/0087 15 OCT 2020
6370
6190
50mm MIN
STEP DOWN 90
2790
TILED DECK
4300
2500
MASTER
WIR BALUSTRADE PF.B PF.B BALUSTRADE
BEDROOM
BALUSTRADE BALUSTRADE
robe
90
90
90
90
1890
1890
200
POOL
900
90 90 ALL TRADES PEOPLE TO WORK
SAFELY ON THIS SITE SD DENOTES SMOKE ALARM
ALL CONSTRUCTION TO BE CARRIED OUT BY LICENCED PERSONS AND IN ACCORDANCE WITH RECOMMENDATIONS
90 IN ACCORD. WITH BCA (NCC) REQUIREMENTS AND RELEVANT OF NCC PART 3.7.2 - SMOKE ALARMS
90
90
90 510 1630 780 2090 90 150 3500 AUSTRALIAN STANDARDS. AND INTERCONNECTED AS PER NCC PART 3.7.2.2
ALL STRUCTURAL DETAILS AND SIZINGS TO BE DETAILED SEAL WET AREAS IN ACCORDANCE
90 BY STRUCTURAL ENGINEER. WITH AS 3740 & THE BCA.
90 510 920 380 3200 90 14100 90 7840 90 FOR ALL STRUCTURAL DETAILS
SUCH AS TIMBER SIZES, BRACING,
5280 14100 8020 TIE-DOWN AND FOOTING DETAILS,
REFER TO THE ENGINEERS
27400 DRAWINGS & SPECIFICATIONS.
FW - DENOTES FLOOR WASTE
PROVIDE LIFT OFF HINGES TO WC DOOR
No. Description Date
Working Drawings Upper Floor Plan
29/07/2020 8:13:39 AM
Ric Stevens
199 Maximillian Road Project number 2440 REV 3 Revision
D E S I G N E RS : T I M & P H I L C H R I S T O P H E R & AS SOCIATES
email : [email protected] www.christopherdesigngroup.com.au BDAQ member
North Shore Date 29-7-20 Sheet 3
Drawn by PC
CHRISTOPHER DESIGN GROUP PTY LTD QBCC LICENSE No. 1307316
5/70 Bulcock Street CALOUNDRA Qld AUSTRALIA
ACN 604467450
OFFICE PH: 07 5491 4666
Proposed Residence Checked by TC Scale 1 : 100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans MCU20-0087.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (small file)
- File type
No other editions are linked here.