                                                                                                     TRUSSES TO TRUSS MANUFACTURERS SPECIFICATIONS
                                                             W                                                                                                                                           COLORBOND CUSTOM ORB ULTRA ROOF SHEETING TO BE USED
                                           W                 6                                                                                                                                           FOR ROOF PITCHES OF 5 DEG OR GREATER.
                                           8
                                                                                                                 5 DEG ROOF PITCH. COLORBOND CUSTOM ORB ROOF SHEETING
                                                                                                                 (TO SUIT ENVIRONMENT) FIXED AND FLASHED TO MANUF. SPECS                                 ROOF INSULATION DETAILS:
                W       W
              12A      12B                                            2000                                                                                                   900                         BULK INSULATION : ANTICON UNDER ROOF SHEETING & BATTS TO CEILING
                                                                                                                                                                                                         TO BE AS PER ENERGY ASSESSORS REQUIREMENTS

                                                                                                                                                                                                         PINE TRUSSED ROOF FRAMING TO ALL AREAS EXCEPT WHERE
                                                                                                                                                                                                         SHOWN AS RAKED OR RAFTERED CEILING.

                                                                                                                                                                                                         SARKING TO BE PROVIDED TO ALL EXTERNAL WALLS.
                                                                                                                                                                                                         INSULATION TO ALL WALLS AS PER ENERGY REQUIREMENTS

                                                                                                                                                                                                         WALL CONSTRUCTIONS INCLUDE:
                                                                                                                                                                                                         1. JAMES HARDIE LINEA 180 CLADDING WITH A PAINTED FINISH


                                                                                                                                                                                                         ALL CONSTRUCTION TO BE CARRIED OUT IN ACCORDANCE
                                                                                                PLASTERBOARD LINING TO CEILING                                                                           WITH THE BCA, A.S., INCL AS1684, QDC AND THE STANDARD
                                                                                                                                                                                                         BUILDING REGULATIONS, ALONG WITH LOCAL COUNCIL REQUIRMENTS
                                                                                                                                                                                                         AND ESTATE COVENANTS.

                                                                                                                                                                                                         NO SUBSTITUTION OF PRODUCTS OR MATERIALS SPECIFIED




                                                                                                                                   FINISHED HEIGHT
                                                                                                                                                                                                         IS ALLOWED WITHOUT PRIOR PERMISSION FROM THE AUTHOR.




                                                                                                                                                     2700
                                                                                                                                                                                                         NO RESPONSIBILTY WILL BE TAKEN BY CHRISTOPHER DESIGN GROUP FOR
                                                                                                                                                                                                         ANY AMENDMENTS OR VARIATIONS MADE TO THESE PLANS
                                                                                                                                                                                                         WITHOUT WRITTEN CONSENT.

                                                                                                                                                                                                         ALL DIMENSIONS ARE TO BE VERIFIED BY THE BUILDER
                                                                                                                                                                                                         PRIOR TO ORDERING ANY MATERIALS

                                                                                                                                                                                                         DIMENSIONS ON THESE PLANS ARE TO BE USED OVER SCALE


                                                                                                                                                                                                         SEAL WET AREAS IN ACCORD.
                                                                                                                                                                                                         WITH AS 3740 & THE BCA. (NCC)

                                                                                                                                                                                                         ALL CONSTRUCTION TO BCA REQUIREMENTS,
                                                                                                                          OPEN UNDER FLOOR                                                               S.B.R AND THE AUSTRALIAN STANDARDS.
                                                                                                                          SHS POST LAYOUT
                                                                                                                          TO ENGINEERS DRAWINGS                                                          BUILDER TO VERIFY ALL DIMENSIONS
                                                                                                                                                                                                         PRIOR TO ORDERING ANY MATERIALS.

                                                                                                                 TIMBER FLOOR FRAMING                                                                    NOTE: ALL PRIMARY BUILDING ELEMENTS TO BE
                                                                                                                                                                                                         TERMITE RESISTANT.

                                                                                                        CONCRETE BLOCKWORK RETAINING WALLS                                                               PLASTERBOARD LINING THROUGHOUT WALLS & CEILINGS INTERNALLY.
                                                                                                        TO ENGINEERS DETAILS                                                                             HARDIFLEX EAVES LINING OR SIMILAR FC USED IN SOFFIT AND EXTERNAL CEILING
                                                                                                                                                                                                         UNLESS NOTED OTHER, ALL WITH A PAINTED FINISH TO MANUF. SPECS.



                                                                                                                                                                                                         BUSHFIRE RATING - BAL 12.5
                                                                                                                                                                                                         (PROVIDED BY FIRE RATING ASSESSOR)

                                                                                                                                                                                                         ALL CONSTRUCTION IN THIS HOME MUST MEET
                                                                                                                                                                                                         THE BAL 12.5 REQUIREMENTS AS SET OUT IN
            Section
          1 1 : 50  1-1                                                                                  90 x 90mm SHS GALV SUPPORT POSTS
                                                                                                                                                                            NOOSA COUNCIL
                                                                                                                                                                            APPROVED PLAN
                                                                                                                                                                                          -
                                                                                                                                                                                                         AS 3959-2009 AND ITS LATEST AMENDMENTS.

                                                                                                                                                                                                         ALL TIMBER USED IN THIS HOME MUST MEET
                                                                                                         TO ENGINEERS DETAILS
                                                                                                                                                                         MCU20/0087 15 OCT 2020          THIS CODE AND APPENDIX E, F, & H


                                                                                               No.                 Description                              Date
                                                                                                                                                                   Working Drawings               Section 1




                                                                                                                                                                                                                                                                                       29/07/2020 8:13:44 AM
                                                                                                                                                                   Ric Stevens
                                                                                                                                                                   199 Maximillian Road           Project number             2440 REV 3                                     Revision

D E S I G N E RS : T I M & P H I L C H R I S T O P H E R           &     AS SOCIATES
email : [email protected] www.christopherdesigngroup.com.au BDAQ member
                                                                                                                                                                   North Shore                    Date                           29-7-20         Sheet 15
                                                                                                                                                                                                  Drawn by                               TC
CHRISTOPHER DESIGN GROUP PTY LTD QBCC LICENSE No. 1307316
5/70 Bulcock Street CALOUNDRA Qld AUSTRALIA
                                                                             ACN 604467450
                                                                     OFFICE PH: 07 5491 4666
                                                                                                                                                                   Proposed Residence             Checked by                             TC   Scale                  As indicated

Used in these records

About this file

File size
2.0 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plans MCU20-0087.pdf · 2.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.