Council archive · source document
H083-14 Eng rev A · 132000.200278.6
Attached to the e-mail Change to DA (enclose part of verandah) - 132000.200278.6.
2/14-10-42 tek screws
VERANDAH BEAM top and btm
FABRICATED CHANNEL
VERANDAH BEAM
FABRICATED CHANNEL
RAFTER C15012
@ 900 CRS
VERANDAH BEAM 2/14-10-42 tek screws
FABRICATED CHANNEL top and btm
CONTINUOUS
SECTION A-A
RAFTER C15012 FIXING DETAIL
@ 900 CRS
SCALE 1:10
Existing Post
EXISTING ROOF
A
-
55
160
3
FABRICATED CHANNEL
SCALE 1:10
ROOF PLAN
EXISTING FASCIA VERANDAH BEAM
VERANDAH BEAM CONTINUOUS
CONTINUOUS Existing Channel and Cleat
2/M12 Bolts 2/M12 Bolts
2/M12 Bolts
VERANDAH BEAM
CONTINUOUS
100x4.0mm SHS post 100x4.0mm existing SHS post
with 8mm cap plate with 8mm cap plate
8mm cleat 8mm cleat 2/M12 Bolts
6mm CF weld 6mm CF weld
Existing SHS Post Existing Channel and Cleat
8mm cleat
6mm CF weld
BEAM TO NEW POST
FIXING DETAIL PLAN VIEW
SCALE 1:10 SCALE 1:10
BEAM TO EXISTING POST
FIXING DETAIL
SCALE 1:10
No. Description Date HINDMARSH PROPERTY SERVICES APPROVED
AAA Design & Development Pty Ltd ROOF PLAN
Lot 308 Eumundi-Noosa Rd
34/13 Norval Court, MAROOCHYDORE, QLD 4558
NOOSAVILLE, QLD 4566 Project number H083-14
Tel/Fax: (07) 5479 6747
Mob: 0422 039 247 Date 28-08-2018
2010 - 02A
email: [email protected] design & Drawn by J.S
PROPOSED DWELLING For & on behalf of AAA
Design & Development Consulting Checked by D.L.T Scale @ A3 1:100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
CONCRETE/FOUNDATION NOTES:
1. All concrete shall be 20MPa UNO with 20mm nominal
maximum aggregate size and 80mm slump to AS3600.
2. No on site water to be added to the concrete unless
approved by the engineer.
3. All Concrete to be mechanically vibrated so that the
concrete is fully compacted U.N.O.
4. Concrete is to be cured for a minimum of 7 days after
initial set. The curing method is to be approved by the
engineer.
100x4.0 SHS POST
5. Cover to reinforcement to be 40mm for all steelwork
6. Concrete shall not be poured when the air
temperature is greater than 38 degrees or less than 5
degrees.
7. Concrete footings and floors to be inspected by the Existing Post 200x200x8 BASE PLATE CHEMSET
EXISTING FOOTING
engineer prior to pouring. The engineer is to be given 2/M12 CHEMSETS RAMSET 101
24 hrs. notice of such an inspection being required. 110 mm EMBEDMENT MIN
P1
8. Slab Mesh is to be lapped so as the two outermost
transverse wires of one sheet overlap the two
outermost transverse wires of the other sheet.
9. All Reinforcement shall be adequately supported P1
before commencement of concrete pour to ensure
cover and placement of steel is maintained.
10. Controlled Fill shall be clean granular material (free
of clay) compacted to 95% standard compaction in Existing Post Existing Post P1
layers no greater than 150mm
11. FOUNDATION MATERIAL: Organic Material, soft spots,
top soil and any other deleterious material shall be SHS IN SLAB DETAIL
removed from footing or slab excavations. Excavations FOOTING LAYOUT SCALE 1:10
shall then be proof rolled and soft spots replaced with
controlled fill if under slabs or 15Mpa mass concrete
if under footings. Site to have a nominal bearing capacity
of 100kPa and classification not greater than 'S'.
12. Footings shall be founded below the bottom of
existing or proposed adjoining service trenches.
Excavations shall not be taken below the bottom
of adjoining footings.
13. The site shall be graded so that water cannot pond
against or near the house.
14. Care should be taken to control the flora so as to
not adversely affect the drainage of the site.
15. Site Classification "H1" assumed.
No. Description Date HINDMARSH PROPERTY SERVICES APPROVED
AAA Design & Development Pty Ltd CONCRETE FOOTING LAYOUT
Lot 308 Eumundi-Noosa Rd
34/13 Norval Court, MAROOCHYDORE, QLD 4558
NOOSAVILLE, QLD 4566 Project number H083-14
Tel/Fax: (07) 5479 6747
Mob: 0422 039 247 Date 28-08-2018
2010 - 01A
email: [email protected] design & Drawn by J.S
PROPOSED DWELLING For & on behalf of AAA
Design & Development Consulting Checked by D.L.T Scale @ A3 1:100
Used in these records