Original source · versioned page text
Appendix C Residential Uses codes
Attached to the e-mail Multiple Housing Type 2 Duplex - MCU18/0003.
Appendix C - Residential Uses Code Development Permit for Material Change of Use for Type 2 Duplex at 20 Nannygai Street Noosaville described as Lot 36 on RP63879 14.45 Specific Outcomes, probable solutions and acceptable solutions for the Residential Uses Code Table 14.24 — For All Residential Uses column 1 column 2 Column 3 Specific Outcomes Probable solutions (if code assessable) Compliance Effects of use Electricity supply infrastructure O1 The development does not adversely S1.1 No solution provided Complies impact on existing or future electricity supply S2.1 Development for uses adjacent to or infrastructure; AND within 50m of an existing electricity O2 All uses and works maintain an substation incorporates noise attenuation adequate safe distance from electrical measures to mitigate noise impacts; AND infrastructure including substations, S2.2 Buildings and structures (including overhead powerlines, power poles and swimming pools, sheds, tennis courts or transformer outbuildings) are not constructed under overhead electricity transmission lines, or within electricity easements; AND S2.3 A minimum separation distance is maintained from the electricity transmission line to the closest boundary of habitable buildings and child activity areas, as follows— a) 20m for transmission lines up to 132kV; b) 30m for transmission lines between 133kV and 275kV; and c) 40m for transmission lines greater than 275kV Environmentally Sustainable Building Design Hot Water Systems1 O3 Hot water systems are installed and S3.1 All hot water systems installed are— Proposal will comply with relevant Council operated to support the efficient use of a) solar systems; or policies and standards natural resources and minimise consequent b) electric heat pump systems; or pollution such as greenhouse gas emissions. c) natural gas or LPG systems; or d) any combination of a), b) or c). Water supply and conservation O4 Not applicable Erosion and sediment control O5 Development does not cause erosion No solution provided Proposal will comply with relevant Council or result in transport of sediments off-site. policies and standards Amenity and Built form Safety and security O6 For Multiple Housing Types 2, 3 and S6.1 The building entrance is clearly Complies - Building entrance to each of the 4, buildings and outdoor spaces are identifiable and visible from the street, units is defined by pathways leading to the designed to protect the personal security and footpath and driveway; entrance area. Pathways to be lit and have safety of residents by allowing for natural AND direct access to the entrance area of each surveillance S6.2 The internal path network has clear unit. Gatehouse proposed at each accessway sightlines to the dwelling entry and street to the site. access points; AND S6.3 Visitors have direct access to the entrance without passing through private outdoor living areas. Emergency access O7 For Multiple housing Type 3, 4 & 5 No solution provided Not applicable Basement drainage O8 Buildings and access works are designed S8.1 Enclosed car parking and Complies and sited to protect persons and property in manoeuvring areas are constructed at a the level that permits the parking area to drain event of a flood and power failure. from the site by gravity means, without the need for mechanical pumping 1 This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.